An investigation on seismic performance of the separated fluid inerter base on model experiment and shaking table test

被引:2
|
作者
Liao, Yangyang [1 ]
Tang, Hesheng [1 ]
Guo, Taikun [1 ]
Li, Rongshuai [2 ]
Xie, Liyu [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Disaster Mitigat Struct, Shanghai 200092, Peoples R China
[2] Shanghai Construct Grp Co Ltd, Shanghai 200080, Peoples R China
基金
中国国家自然科学基金;
关键词
Vibration control; Separated fluid inerter; Model experiment; FS-BIFI; Shaking table test; TUNED MASS DAMPERS; MITIGATION; DESIGN;
D O I
10.1016/j.istruc.2024.107379
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fluid inerters have gained attention in structural vibration control for their simplicity, durability, high energy dissipation, and significant apparent mass amplification. This study presents an innovative design of a separated fluid inerter, which enhances inertial force, allows for more flexible installation methods, and supports a wider range of connections. A mechanical model is developed and experimentally validated for the separated fluid inerter. The effects of key design parameters on the device's mechanical properties are examined, with a focus on the radii (r(1)) and length (l) of the helical tube and the radii (r(2)) of hydraulic cylinder. Theoretical and experimental results confirm the model's reliability and the sensitivity of the device to these parameters. Additionally, a combination of the separated fluid inerter with anti-overturning rolling isolation is applied to a frame structure, and its seismic performance is evaluated through the shaking table test. The results indicate that the separated fluid inerter can effectively reduce the displacement of the isolation layer without significantly increasing the top floor acceleration of the frame structure equipped base isolation (FS-BI).
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Seismic performance analysis of rocking wall TMDs structure based on shaking table test
    Nie W.
    Liu S.
    Lu S.
    Liu S.
    Yin C.B.A.H.
    Earthquake and Structures, 2021, 21 (01): : 23 - 36
  • [42] Seismic performance of arch-inverted siphon based on a large shaking table test
    Wu Y.
    Luo B.
    Zhang W.
    Liao Y.
    Gao Y.
    Jiang L.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2024, 64 (07): : 1193 - 1202
  • [43] A shaking table test of the seismic performance of a shear wall residential building with large scale
    Gao H.
    Zhang L.
    Li H.
    Zhu B.
    Li R.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2022, 41 (12): : 117 - 124
  • [44] Seismic Performance of Geosynthetic Reinforced Soil-Integrated Structure in Shaking Table Test
    Luo M.
    Xu C.
    Yang Y.
    Yang Z.
    Tongji Daxue Xuebao/Journal of Tongji University, 2019, 47 (11): : 1541 - 1547
  • [45] Shaking table test study on seismic performance of UHPC rectangular hollow bridge pier
    Ye, Mengya
    Guo, Zhan
    Chen, Canwen
    Chen, Yu
    Composite Structures, 2021, 275
  • [46] Shaking table test study on seismic performance of UHPC rectangular hollow bridge pier
    Ye, Mengya
    Guo, Zhan
    Chen, Canwen
    Chen, Yu
    COMPOSITE STRUCTURES, 2021, 275
  • [47] Shaking table test on the seismic performance of ternary composite geopolymer recycled concrete frame
    Li, Yin
    Huang, Liang
    Qu, Yiqun
    Liu, Haoqi
    Lv, Bodong
    Li, Shuisheng
    STRUCTURES, 2024, 65
  • [48] Seismic performance analysis of rocking wall TMDs structure based on shaking table test
    Nie, Wei
    Liu, Shuxian
    Lu, Shasha
    Liu, Shaodong
    Bai, Chun
    Yin, Hang
    EARTHQUAKES AND STRUCTURES, 2021, 21 (01) : 29 - 42
  • [49] Study on shaking table test of steel frame structure with enhanced particle inerter device
    Lu Z.
    Zhou C.
    Yan D.
    Zhang R.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 48 - 55
  • [50] Shaking Table Model Test for Vertical Seismic Response of Bent-Type Aqueduct
    Duan, Qiuhua
    Lou, Menglin