Thermodynamic analysis of a solar powered ejector cooling system

被引:0
作者
Khennich, Mohammed [1 ]
Galanis, Nicolas [2 ]
Sorin, Mikhail [2 ]
Orfi, Jamel [3 ]
Sarrafi, Ahmadreza [1 ]
Dupuis, Serge [4 ]
机构
[1] Mechanical Engineering Department, Université de Moncton, Moncton, NB
[2] Mechanical Engineering Department, Université de Sherbrooke, Sherbrooke, QC
[3] Mechanical Engineering Department, King Saud University, Riyadh
[4] Civil Engineering Department, Université de Moncton, Moncton, NB
来源
International Journal of Thermofluids | 2024年 / 24卷
基金
加拿大自然科学与工程研究理事会;
关键词
Climate change mitigation; Coefficient of performance (COP); Ejector; Exergy efficiency; Parabolic trough collector; Solar powered cooling system;
D O I
10.1016/j.ijft.2024.100960
中图分类号
学科分类号
摘要
A steady-state model of an ejector cooling system activated by solar heat is presented and applied in response to the increasing demand of cooling in hot-climatic regions. The system comprises three loops connected by heat exchangers. The first loop, or collection sub-system, includes the solar collectors (both cylindrical-parabolic and flat plate collectors are modeled) and the heat transfer fluid (a thermal oil). The second loop also includes an ejector which uses polytropic efficiencies and provides the power necessary to circulate a second low-pressure stream of the refrigerant through the evaporator and an intermediate-pressure condenser. The third loop connects the load to the evaporator using ethylene glycol. In this study, the model is particularly based on the laws of classical and finite size thermodynamics and incorporates experimentally derived relations for the efficiency of the cylindrical-parabolic collectors as well as an ejector model which is based on physical laws rather than on refrigerant specific correlations used in previous studies. The results include a parametric study analysing the effect of the generator superheating and the calorific flow of the heat transfer fluid on the ejector dimensions and the overall system performance. The impact of the solar collector type on the collector surface and the system performance by a fixed incident radiation was investigated. The results illustrate that using parabolic trough collectors, the exergy efficiency of the entire system and the required collector's area are almost constant with the solar radiation intensity. They are approximately 35 % and 35 m2 respectively. It was also shown that further superheating the refrigerant by an additional 10 °C at the generator exit reduces the ejector's total length by 8.1 %, leading to positive economic impacts on raw material acquisition for the solar-powered ejector refrigeration system. Furthermore, doubling the calorific flow reduced the COP by half and increased the ejector length. The economic analysis of the system reveals two key findings: The largest portion of the initial costs is attributed to the solar collector, which is essential for providing the thermal energy required for the system's operation. The main hourly expense of the system is the electricity cost associated with powering the pumps. © 2024
引用
收藏
相关论文
共 50 条
  • [31] Exergetic performance evaluation of ejector cooling system
    Tirmizi, Syed A.
    Gandhidasan, P.
    Zubair, Syed M.
    INTERNATIONAL JOURNAL OF EXERGY, 2011, 9 (01) : 80 - 98
  • [32] Theoretical and experimental study on solar ejector cooling system using R236fa
    Zhang, B.
    Lv, J. S.
    Zuo, J. X.
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2014, 9 (04) : 245 - 249
  • [33] Exergy Analysis of an Ejector Cooling System by Modified Gouy-Stodola Equation
    Sachdeva, Gulshan
    Sharma, Bharat
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2021, 29 (03)
  • [34] Diurnal performance investigation of solar integrated ejector-based Combined Cooling, Heating, and Power (CCHP) system for Indian climate
    Saladi, Joshua Kumar
    Suresh, Ronanki
    Datta, Santanu Prasad
    APPLIED THERMAL ENGINEERING, 2025, 263
  • [35] Performance Analysis of a Solar-powered Ejector Air-conditioning Cycle with Heavier Hydrocarbons as Refrigerants
    Gil, Bartosz
    Kasperski, Jacek
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2619 - 2628
  • [36] Investigation of a novel solar-driven refrigeration system with ejector
    Bellos, Evangelos
    Theodosiou, Ioannis-Christos
    Vellios, Loukas
    Tzivanidis, Christos
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 8 : 284 - 295
  • [37] Thermodynamic analysis of Organic Rankine Cycle with Ejector
    Li, Xinguo
    Zhao, Cuicui
    Hu, Xiaochen
    ENERGY, 2012, 42 (01) : 342 - 349
  • [38] Thermodynamic analysis of a novel solar trigeneration system
    Beygzadeh, V
    Khalilarya, Sh
    Mirzaee, I
    Miri, Gh
    Zare, V
    SCIENTIA IRANICA, 2021, 28 (01) : 326 - 342
  • [39] Experimental investigation on ejector cooling system performance at low generator temperatures and a preliminary study on solar energy
    R. Yapıcı
    F. Akkurt
    Journal of Mechanical Science and Technology, 2012, 26 : 3653 - 3659
  • [40] Experimental investigation on ejector cooling system performance at low generator temperatures and a preliminary study on solar energy
    Yapici, R.
    Akkurt, F.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (11) : 3653 - 3659