STUDY ON ANALYTICAL MODEL FOR STRUCTURAL PERFORMANCE EVALUATION OF R/C SOFT-FIRST STORY FRAME RETROFITTED WITH UFC PANELS

被引:0
|
作者
Misumi K. [1 ]
Mukai T. [2 ]
Watanabe H. [3 ]
Kinugasa H. [1 ]
机构
[1] Dept. of Architecture, Tokyo Univ. of Science
[2] Building Dept., National Institute for Land and Infrastructure Management
[3] Dept. of Structural Engineering, Building Research Institute
关键词
Analytical model; Seismic retrofit; Soft-first story frame; UFC panel;
D O I
10.3130/aijt.28.667
中图分类号
学科分类号
摘要
In the 2016 KUMAMOTO earthquake, the R/C soft-first story building designed after 1981 was severely damaged. To mitigate the damage, study on seismic retrofit with UFC panels has been conducted. Investigation to evaluate structural performance of the retrofitted building with soft-first story is necessary. This paper presents an analytical model for the retrofitted R/C soft-first story frame specimen with UFC panels. The modeling method for such as column retrofitted with UFC panel are discussed, especially it's focused on structural performance of this retrofitted specimen dependents on mortar in joint between UFC panel and concrete stubs. © 2022 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:667 / 672
页数:5
相关论文
共 8 条
  • [1] Cyclic loading tests on damaged R/C soft-first story columns retrofitted by sandwiching and bonding UFC panels
    Kumabe A.
    Tani M.
    Mukai T.
    Watanabe H.
    Nishiyama M.
    Ishioka T.
    Hattori T.
    Matsumoto D.
    Hori S.
    AIJ Journal of Technology and Design, 2021, 27 (67) : 1273 - 1278
  • [2] Earthquake retrofitting of R/C frames with soft first story using hysteretic dampers: Energy-based design method and evaluation
    Benavent-Climent, A.
    Mota-Paez, S.
    ENGINEERING STRUCTURES, 2017, 137 : 19 - 32
  • [3] Experimental and analytical investigation of 1/3-model R/C frame-wall building structures - Part 1 (model design and analytical evaluation of dynamic characteristics of the model)
    Garevski, M
    Paskalov, A
    Talaganov, K
    Hristovski, V
    SEISMIC ASSESSMENT AND REHABILITATION OF EXISTING BUILDINGS, 2003, 29 : 487 - 498
  • [4] Experimental and analytical investigation of 1/3-model R/C frame-wall building structures - Part II (nonlinear analytical prediction of structural behavior)
    Garevski, A
    Hristovski, V
    Paskalov, A
    Talaganov, K
    SEISMIC ASSESSMENT AND REHABILITATION OF EXISTING BUILDINGS, 2003, 29 : 499 - 516
  • [5] EXPERIMENTAL STRUCTURAL PERFORMANCE EVALUATION OF 2.5-STORY MODEL FRAME REPRESENTING LOWER STORIES OF HIGH-RISE RC BUILDINGS WITH FLAT WALLS
    Uchida B.
    Sanada Y.
    Yoon R.
    Quan C.
    Zhao P.
    Journal of Structural and Construction Engineering, 2023, 88 (809): : 1197 - 1207
  • [6] EXPERIMENTAL STUDY ON THE STRUCTURAL PERFORMANCE OF RC SOFT-FIRST-STORY COLUMN-BEAM JOINTS WITH MECHANICAL ANCHORAGE OF COLUMN LONGITUDINAL REBAR
    Hoshiya H.
    Sanada Y.
    Yoon R.
    Kaneko Y.
    Journal of Structural and Construction Engineering, 2023, 88 (805): : 490 - 499
  • [7] Pushover model for beam-column joint in RC soft-first-story frame with column extended toward inside: Study on joint subjected to closing load
    Uno K.
    Suzuki T.
    Takahashi S.
    Ichinose T.
    Journal of Structural and Construction Engineering, 2016, 81 (728): : 1703 - 1712
  • [8] Evaluation on ultimate strength of beam-column joint in rc soft-first-story frame with column extended outside building: Study on joint subjected to closing load
    Miyake M.
    Suzuki T.
    Uno K.
    Morinaga K.
    Hoshi T.
    Kusuhara F.
    Ichinose T.