Development of reinforced concrete column with replaceable plastic hinge based on metabolism concept

被引:1
|
作者
Uemura, Keita [1 ]
Hayashi, Manabu [2 ]
Nishine, Koki [3 ]
Takahashi, Yoshikazu [1 ]
机构
[1] Kyoto Univ, Dept Civil & Earth Resources Engn, Nishikyo Ku, Kyoto 6158540, Japan
[2] Muramoto Corp, Engn Dev Dept, Tennoji Ku, Osaka 5430002, Japan
[3] Muramoto Corp, Osaka Branch, Tennoji Ku, Osaka 5430002, Japan
关键词
Reinforced concrete; Column structure; Metabolism; Design for Disassembly; Seismic performance; Replacement; Repair; ROCKING BRIDGE PIERS; SEISMIC BEHAVIOR; RETROFIT; POLYMER;
D O I
10.1016/j.engstruct.2024.119007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To update seismic performance and rapidly restore the transportation capacity of a bridge following an earthquake, this study introduces a new reinforced concrete (RC) column, termed "Metabolic RC column," which incorporates the Design for Disassembly and Metabolism Movement concepts. The proposed column features a plastic hinge comprising a permanent hinge and replaceable plastic zones. A Mesnager hinge is employed as the permanent hinge to resist the axial loads within the column cross section. In addition, cast-in-place RC members are used in replaceable plastic zones to dissipate the seismic energy. By replacing the plastic zone with an equivalent or superior alternative while the permanent hinge continues to carry the axial forces, the updating (i. e., metabolization) of the column seismic performance can be achieved without interrupting the daily operations of the structure. The feasibility of replacing plastic hinges while maintaining the resistance to axial loads was demonstrated through plastic zone replacement tests. Cyclic loading tests indicated that the maximum lateral load of the proposed Metabolic RC Column remained unchanged before and after the plastic zone replacement. The energy dissipated also remained nearly consistent before and after the plastic zone replacement. The largest reduction in dissipated energy at each displacement amplitude was approximately 6.7 % before and after replacement. Additionally, the cyclic loading tests emphasized the importance of minimizing damage to the permanent hinge and preventing the axial stiffness reduction to ensure maximum load capacity of the column after plastic zone replacement. Further, a numerical model was developed to replicate the load-displacement relationship of the specimens. The proposed model accurately calculated the maximum load of the specimen with an average error of approximately 3 % for each displacement amplitude and the dissipated energy with an error of approximately 6 %. The numerical analysis effectively captured the changes in the secondary stiffness of the columns before and after plastic zone replacement, attributing the differences in secondary stiffness to the reduced tensile forces exerted by the permanent hinge rebar.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] Research on equivalent plastic hinge length of reinforced concrete bridge column
    Sun, Zhi-Guo
    Wang, Dong-Sheng
    Guo, Xun
    Li, Xiao-Li
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2011, 24 (05): : 56 - 64
  • [2] Shear strength model for plastic hinge region of reinforced concrete column
    Wei W.
    Shao C.
    Huang H.
    Li Z.
    Han G.
    Zhuang W.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2023, 56 (09): : 54 - 64
  • [3] Seismic behavior of a replaceable artificial controllable plastic hinge for precast concrete beam-column joint
    Huang, Hua
    Yuan, Yujie
    Zhang, Wei
    Li, Ming
    ENGINEERING STRUCTURES, 2021, 245
  • [4] Calculation of Shear Capacity of Plastic Hinge Zone of Hydraulic Reinforced Concrete Column
    Ma, Ying
    Li, Mengdie
    Sun, Zhiguo
    Wu, Zebin
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2022, 54 (06): : 204 - 211
  • [5] Experimental Design of Shear Resistance of Plastic Hinge of 500 MPa Reinforced Concrete Column
    Wang Shuai
    Shi Jingchen
    Lv na
    Yuan Xinjie
    2020 5TH INTERNATIONAL CONFERENCE ON SMART GRID AND ELECTRICAL AUTOMATION (ICSGEA 2020), 2020, : 111 - 114
  • [6] Plastic hinge length of reinforced concrete columns
    Bae, Sungjin
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2008, 105 (03) : 290 - 300
  • [7] Plastic hinge of reinforced concrete beam based on fiber element model
    Chen Xiaoming
    Duan Jin
    Li Yungui
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2017), 2017, 143 : 46 - 50
  • [8] ANALYTICAL PROCEDURE AND EXPERIMENTAL RESEARCH ON LUMPED PLASTIC HINGE MODEL FOR REINFORCED CONCRETE BRIDGE COLUMN
    Li, Xu
    Zhong, Tieyi
    Yang, Haiyang
    Wang, Fei
    NEW TECHNOLOGIES OF RAILWAY ENGINEERING, 2012, : 715 - 720
  • [9] Study on the equivalent plastic hinge length of reinforced concrete circular double-column piers
    Dong, Huihui
    Feng, Wenhao
    Wang, Yudi
    Han, Qiang
    Du, Xiuli
    STRUCTURES, 2025, 74
  • [10] Simplified Plastic Hinge Model for Reinforced Concrete Beam-Column Joints with Eccentric Beams
    Hwang, Hyeon-Jong
    Kim, Chang-Soo
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 14