The impact protection behavior of UHPC composite structure on RC columns

被引:2
作者
Xia, Hongxiang [1 ,2 ,3 ,4 ]
Fang, Xueqian [1 ,2 ]
Yu, Qingxin [5 ]
Wang, Shijie [4 ,6 ]
Huang, Yong [7 ,8 ]
Sun, Quansheng [4 ]
机构
[1] Dongguan Univ Technol, Sch Environm & Civil Engn, Dongguan 523808, Peoples R China
[2] Guangdong Prov Key Lab Intelligent Disaster Preven, Dongguan 523808, Peoples R China
[3] Tianjin Univ, Sch Mech Engn, Tianjin 300354, Peoples R China
[4] Northeast Forestry Univ, Sch Civil Engn, Harbin 150040, Peoples R China
[5] Lianyungang Econ & Technol Dev Zone Govt Investmen, Lianyungang 222069, Peoples R China
[6] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[7] China Earthquake Adm, Key Lab Earthquake Engn & Engn Vibrat, Inst Engn Mech, Harbin 150080, Peoples R China
[8] Minist Emergency Management, Key Lab Earthquake Disaster Mitigat, Harbin 150080, Peoples R China
关键词
Structural Impact; UHPC; Honeycomb structure; Composite structure; Numerical simulation; HIGH-PERFORMANCE CONCRETE; ENERGY-ABSORPTION CHARACTERISTICS; DYNAMIC COMPRESSIVE BEHAVIOR; BRIDGE COLUMNS; STEEL FIBER; CEMENTITIOUS COMPOSITES; TENSILE BEHAVIOR; STRENGTH; BEAMS; SENSITIVITY;
D O I
10.1016/j.cscm.2024.e03866
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to prevent the reinforced concrete (RC) structures from being damaged under the overload impact, a new type of composite structure-ultra-high performance concrete (UHPC)- Bio-inspired honeycomb column thin-walled structure (BHTS) was designed in this paper. A scale model with a scaling factor of 1:10 was made. The experimental tests and numerical simulations of RC column and UHPC composite structure were carried out. By comparing the impact force, displacement, shear force, bending moment and energy absorption, the protective effect of the UHPC-BHTS composite structure on RC columns under lateral impact load was evaluated. Then, the failure process of RC column was analyzed, the UHPC-BHTS composite structure absorbed 76.42 % of the impact kinetic energy under the higher energy input condition, the shear failure with large damage to the RC column can be converted into bending failure with small damage. At the same time, a new damage assessment method was used to evaluate the RC column. The results show that the RC column with UHPC-BHTS composite structure can effectively protect the RC column's structural integrity under impact. The design and modeling methods in this research can provide a useful reference for anti-collision design in practical engineering.
引用
收藏
页数:19
相关论文
共 50 条
[41]   Axial behavior of RC columns retrofitted with FRP composites [J].
Ilki, Alper ;
Peker, Onder ;
Karamuk, Emre ;
Demir, Cem ;
Kumbasar, Nahit .
ADVANCES IN EARTHQUAKE ENGINEERING FOR URBAN RISK REDUCTION, 2006, 66 :301-+
[42]   AXIAL BEHAVIOR OF RC COLUMNS RETROFITTED USING BAMBOO REINFORCED CONCRETE JACKET [J].
Wibowo, Ari ;
Wijatmiko, Indradi ;
Nainggolan, Christin Remayanti .
INTERNATIONAL JOURNAL OF GEOMATE, 2019, 17 (60) :16-23
[43]   Axial compressive property of UHPC plate-CFST laced composite columns [J].
Wei, Jiangang ;
Xie, Zhitao ;
Zhang, Wei ;
Yang, Yan ;
Luo, Xia ;
Chen, Baochun .
CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 16
[44]   Performance Analysis of CFRP Composite Strips Confined RC Columns under Axial Compression [J].
Murugadoss, J. Raja ;
Lee, Byung Jae ;
Bang, Jin Wook ;
Prabhu, G. Ganesh ;
Kim, Yun Yong .
ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2015, 2015
[45]   Flexural behavior of UHPC encased steel composite beams: Experiment and numerical simulation [J].
Chen, Guixiang ;
Gan, Tian ;
Gao, Xiaolong .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226
[46]   FRP-Concrete-Steel Double-Skin Tubular Columns with UHPC/ECC: Concept and Compressive Behavior under Concentric Loading [J].
Chen, G. M. ;
Lin, Z. H. ;
Liu, Q. ;
Lin, Guan ;
Xiong, Y. ;
Guo, Y. Z. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2023, 27 (03)
[47]   Prediction Accuracy of Seismic Behavior of RC Noncircular Columns Retrofitted with FRP Sheets and the Impact of Local Concrete Compression Behavior [J].
Ismail, Ahmed M. ;
Fahmy, Mohamed F. M. ;
Wu, Zhishen .
JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (10)
[48]   Effect of Steel Fiber on the Behavior of Circular Steel Tube Confined UHPC Columns Under Axial Loading [J].
Le Hoang, An ;
Fehling, Ekkehard .
STRAIN-HARDENING CEMENT-BASED COMPOSITES, 2018, 15 :482-491
[49]   Experimental study on the behavior of damaged CFRP and steel rebars RC columns retrofitted with externally bonded composite material [J].
Rehman, Atteq Ur ;
Siddiqi, Zahid Ahmad ;
Yasin, Mazhar ;
Aslam, Hafiz Muhammad Shahzad ;
Noshin, Sadaf ;
Aslam, Hafiz Muhammad Usman .
ADVANCED COMPOSITE MATERIALS, 2025, 34 (01) :93-139
[50]   UHPC-filled duct connections for accelerated bridge construction of RC columns in high seismic zones [J].
Tazarv, Mostafa ;
Saiidi, M. Saiid .
ENGINEERING STRUCTURES, 2015, 99 :413-422