Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider

被引:0
|
作者
Pellecchia, Antonello [1 ]
Buonsante, Marco [1 ,2 ]
Borysova, Maryna [3 ]
Colaleo, Anna [1 ,2 ]
Camerlingo, Maria Teresa [1 ]
Longo, Luigi [1 ]
Iodice, Mauro [4 ]
Maggi, Marcello [1 ]
Moleri, Luca [3 ]
Radogna, Raffaella [1 ,2 ]
Sekhniaidze, Givi [5 ]
Simone, Federica Maria [1 ,2 ]
Stamerra, Anna [1 ,2 ]
Venditti, Rosamaria [1 ,2 ]
Verwilligen, Piet [1 ]
Zavazieva, Darina [3 ]
Zaza, Angela [1 ,2 ]
机构
[1] Ist Nazl Fis Nucl, Sez Bari, Via G Amendola 173, Bari, Italy
[2] Univ Bari Aldo Moro, Piazza Umberto I, Bari, Italy
[3] Weizmann Inst Sci, Herzl St 234, Rehovot, Israel
[4] Ist Nazl Fis Nucl, Sez Roma 3, Via Vasca Navale 84, Rome, Italy
[5] Ist Nazl Fis Nucl, Sez Napoli, Via Cintia, Naples, Italy
关键词
MPGD; Gaseous detector; Hadronic calorimeter;
D O I
10.1016/j.nima.2024.169793
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Micro-pattern gaseous detectors (MPGDs) are a promising readout technology for hadronic calorimeters (HCAL) thanks to their good spatial resolution, longevity and rate capability. We describe the development of a HCAL based on MPGDs for an experiment at the proposed Muon Collider. The design of a semi-digital MPGD-HCAL is shown and its performance is calculated with Monte Carlo simulations with high-energy pions, showing an energy resolution down to 8% for 80 GeV pions. We also present the performance of twelve MPGD prototypes with different technologies (MicroMegas, mu-RWELL and RPWELL) assembled and operated in test beam first with high-energy muons and later with pions in a hadronic calorimeter prototype of similar to 1 lambda(I) length; the detectors have a good response uniformity (lower than 17%) and spatial resolution and their performance in the calorimeter shows very good agreement with the Monte Carlo shower calculation.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Development of a Semi-Digital Hadronic Calorimeter Using GRPCs for Future Linear Collider Experiments
    Laktineh, I.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 100 - 102
  • [22] Construction of a Technological Semi-Digital Hadronic Calorimeter Prototype for Future Linear Collider Experiments
    Puerta-Pelayo, Jesus
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2048 - 2054
  • [23] Design and performance studies of a hadronic calorimeter for a FCC-hh experiment
    Faltova, J.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [24] Tests of the level-1 regional calorimeter trigger for the compact muon solenoid experiment at the large hadron collider
    Chumney, P
    Dasu, S
    Jaworski, M
    Lackey, J
    Robl, P
    Smith, WH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 524 - 528
  • [25] The design of a flexible global calorimeter trigger system for the compact muon solenoid experiment
    Brooke, J. J.
    Cussans, D. G.
    Frazier, R. J. E.
    Galagedera, S. B.
    Heath, G. P.
    Huckvale, B. J.
    Nash, S. J.
    Newbold, D. M.
    Shah, A. A.
    JOURNAL OF INSTRUMENTATION, 2007, 2
  • [26] First results on MPGD prototypes in test beam for MPGD-based HCAL at a future Muon Collider experiment
    Colaleo, A.
    Buonsante, M.
    Longo, L.
    Maggi, M.
    Pellecchia, A.
    Radogna, R.
    Simone, F. M.
    Stamerra, A.
    Venditti, R.
    Verwilligen, P. J.
    Zaza, A.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (03)
  • [27] Silicon pad detectors for an electromagnetic calorimeter at future linear collider experiments: Characterisation and test beam results
    Bettini, M
    Borsato, E
    Checchia, P
    Nicoletto, A
    Nadalut, B
    Vallazza, E
    Jaroszewicz, B
    Marczewski, J
    Tomaszewski, D
    Bertolucci, S
    Miscetti, S
    Alemi, A
    Bulgheroni, A
    Caccia, M
    Cappellini, C
    Prest, A
    Kucewicz, W
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 176 - 180
  • [28] Design of a Highly Selective Muon Trigger System for Future Hadron Collider Experiments
    Cieri, D.
    Abovyan, S.
    Danielyan, V.
    Fras, M.
    Kortner, O.
    Kortner, S.
    Kroha, H.
    Nowak, S.
    Richter, R.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [29] A totally active scintillator calorimeter for the Muon Ionization Cooling Experiment (MICE). Design and construction
    Asfandiyarov, Ruslan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 : 451 - 456
  • [30] Study of MicroPattern Gaseous detectors with novel nanodiamond based photocathodes for single photon detection in EIC RICH
    Agarwala, J.
    Chatterjee, C.
    Cicala, G.
    Cicuttin, A.
    Ciliberti, P.
    Crespo, M. L.
    Dalla Torre, S.
    Dasgupta, S.
    Gregori, M.
    Levorato, S.
    Menon, G.
    Tessarotto, F.
    Valentini, A.
    Velardi, L.
    Zhao, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 952