Numerical simulation of two-phase steam ejector applied in novel loop heat pipe

被引:0
|
作者
Zhou Y. [1 ]
Yang X. [2 ]
Ni Y. [2 ]
Liu J. [1 ]
Wei J. [2 ,3 ]
Yan J. [3 ]
机构
[1] Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, Xi’an Jiaotong University, Shaanxi, Xi’an
[2] School of Chemical Engineering and Technology, Xi’an Jiaotong University, Shaanxi, Xi’an
[3] State Key Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Shaanxi, Xi’an
来源
Huagong Xuebao/CIESC Journal | 2024年 / 75卷 / 01期
关键词
condensation; ejector; heat transfer; loop heat pipe; numerical simulation; shock wave; two-phase flow;
D O I
10.11949/0438-1157.20231132
中图分类号
学科分类号
摘要
As an efficient passive phase-change heat transfer device, loop heat pipe (LHP) is widely used in industrial fields such as heat dissipation of high-heat-flux electronic devices. Based on previous research, flat-plate LHP coupled with a micro two-phase steam ejector can significantly improve heat transfer performance. However, the internal flow and heat transfer mechanisms of micro two-phase steam ejector were still unclear, making it difficult to perform forward design and theoretical modeling of novel LHP. The effects of steam-water parameters and mixing chamber structure on the performance and internal flow field distribution of the two-phase steam ejector were studied through numerical simulation. The results show that a condensation shock wave exists downstream of the throat. As back pressure increases, the position gradually moves towards the throat. The intensity of condensation shock wave is positively correlated with back pressure, steam mass flow rate and mixing chamber length, while negatively correlated with water temperature. The maximum back pressure of the ejector is in the range of 40—125 kPa and positively correlated with heat load and water temperature, while negatively correlated with mixing chamber length. Through extensive simulation, the influence of water temperature and mixing chamber length on the operating state and pressure ratio of two-phase steam ejector under design power were obtained. © 2024 Materials China. All rights reserved.
引用
收藏
页码:268 / 278
页数:10
相关论文
共 39 条
  • [1] Wei J J, Liu L, Yang X P., Research progress of loop heat pipes for heat dissipation of high-heat-flux electronic devices, CIESC Journal, 74, 1, pp. 60-73, (2023)
  • [2] Su Q, Chang S N, Zhao Y Y, Et al., A review of loop heat pipes for aircraft anti-icing applications, Applied Thermal Engineering, 130, pp. 528-540, (2018)
  • [3] Beygzadeh V, Khalilarya S, Mirzaee I., Thermodynamic comparison of two novel combined systems based on solar loop heat pipe evaporator, Energy, 206, (2020)
  • [4] Mueller C, Tsvetkov P., A review of heat-pipe modeling and simulation approaches in nuclear systems design and analysis, Annals of Nuclear Energy, 160, (2021)
  • [5] Adachi T, Fujita K, Nagai H., Numerical study of temperature oscillation in loop heat pipe, Applied Thermal Engineering, 163, (2019)
  • [6] Bai L Z, Tao Y B, Guo Y D, Et al., Startup characteristics of a dual compensation chamber loop heat pipe with an extended bayonet tube, International Journal of Heat and Mass Transfer, 148, (2020)
  • [7] Chen X T, Qi C, Wang W, Et al., Heat transfer limit resulting from heat leak in a cryogenic loop heat pipe, Applied Thermal Engineering, 184, (2021)
  • [8] Ji X B, Wang Y, Xu J L, Et al., Experimental study of heat transfer and start-up of loop heat pipe with multiscale porous wicks, Applied Thermal Engineering, 117, pp. 782-798, (2017)
  • [9] Xiong K N, Wu W, Wang S F., Research and development of loop heat pipe with flat evaporator, Chemical Industry and Engineering Progress, 40, 10, pp. 5388-5402, (2021)
  • [10] Wang Y, Ji X B, Zheng X H, Et al., Heat transfer characteristics of loop heat pipe with modulated composite porous wick, CIESC Journal, 66, 6, pp. 2055-2061, (2015)