CFD numerical simulation of tunnel dust pollution control using a negative pressure double extraction ventilation system

被引:5
作者
Nie, Wen [1 ,2 ,3 ]
Cheng, Chuanxing [1 ,2 ,3 ]
Liu, Qiang [1 ,2 ,3 ]
Guo, Lidian [1 ,2 ,3 ]
Hua, Yun [1 ,2 ,3 ]
Zhang, Haonan [1 ,2 ,3 ]
Zhu, Zilian [1 ,2 ,3 ]
机构
[1] Shandong Univ Sci & Technol, Coll Safety & Environm Engn, Qingdao 266590, Shandong, Peoples R China
[2] Shandong Univ Sci & Technol, State Key Lab Min Disaster Prevent & Control Cofou, Qingdao 266590, Peoples R China
[3] Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2024年 / 12卷 / 06期
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
CFD numerical simulation; Tunneling; Dust pollution control; New ventilation system; Occupational health protection; MECHANIZED EXCAVATION FACE; COAL-DUST; DIFFUSION; DRIVEN; EMISSIONS; BEHAVIOR; SCALE; WIND;
D O I
10.1016/j.jece.2024.114736
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To effectively control the dust pollution problem in tunneling, we studied the dust control and removal effect of a novel negative pressure double extraction ventilation system. We first investigated the spatial and temporal evolution law of wind flow and dust under single-pressure entry ventilation conditions, and found that the dust diffused to the tunnel exit within 150 s. The average dust concentrations at the driver's location, the front of the tunnel, and the back of the tunnel were 339.26, 278.39, and 232.43 mg/m3, respectively, and the average dust concentration in the tunnel was 243.74 mg/m3. Subsequently, based on the principle of air extraction and dust control, a negative pressure double extraction dust control system was constructed. The spatial and temporal evolution of wind flow and dust at different locations of the exhaust duct was investigated. When the exhaust duct A was 3.0 m away from the floor of the roadway, CA=3.0 m, and when the exhaust duct B was 4.0 m away from the left wall of the roadway, CB=4.0 m, the average dust concentrations at the driver's location, the front of the tunnel, and the back of the tunnel were 45.62, 164.58, and 5.21 mg/m3, respectively. Compared with single pressure-entry type ventilation, the dust prevention effect of the system improved by 86.55 %, 40.88 %, and 97.76 %, respectively, and this installation position was determined to be the optimal position for dust removal.
引用
收藏
页数:17
相关论文
共 22 条
[21]   CFD simulation of cross-ventilation flow for different isolated building configurations: Validation with wind tunnel measurements and analysis of physical and numerical diffusion effects [J].
Ramponi, R. ;
Blocken, B. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2012, 104 :408-418
[22]   Aeroelastic wind tunnel study and numerical simulation of Concrete-Filled Double-Skin Tubular (CFDST) wind turbine system [J].
Li, Dong ;
Fang, Shijing ;
Sun, Chuang ;
Xu, Fujie ;
Zhao, Jie ;
Lai, Zhichao .
STRUCTURES, 2025, 74