CFD numerical simulation of tunnel dust pollution control using a negative pressure double extraction ventilation system

被引:0
|
作者
Nie, Wen [1 ,2 ,3 ]
Cheng, Chuanxing [1 ,2 ,3 ]
Liu, Qiang [1 ,2 ,3 ]
Guo, Lidian [1 ,2 ,3 ]
Hua, Yun [1 ,2 ,3 ]
Zhang, Haonan [1 ,2 ,3 ]
Zhu, Zilian [1 ,2 ,3 ]
机构
[1] Shandong Univ Sci & Technol, Coll Safety & Environm Engn, Qingdao 266590, Shandong, Peoples R China
[2] Shandong Univ Sci & Technol, State Key Lab Min Disaster Prevent & Control Cofou, Qingdao 266590, Peoples R China
[3] Shandong Univ Sci & Technol, Minist Sci & Technol, Qingdao 266590, Peoples R China
来源
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING | 2024年 / 12卷 / 06期
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
CFD numerical simulation; Tunneling; Dust pollution control; New ventilation system; Occupational health protection; MECHANIZED EXCAVATION FACE; COAL-DUST; DIFFUSION; DRIVEN; EMISSIONS; BEHAVIOR; SCALE; WIND;
D O I
10.1016/j.jece.2024.114736
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To effectively control the dust pollution problem in tunneling, we studied the dust control and removal effect of a novel negative pressure double extraction ventilation system. We first investigated the spatial and temporal evolution law of wind flow and dust under single-pressure entry ventilation conditions, and found that the dust diffused to the tunnel exit within 150 s. The average dust concentrations at the driver's location, the front of the tunnel, and the back of the tunnel were 339.26, 278.39, and 232.43 mg/m3, respectively, and the average dust concentration in the tunnel was 243.74 mg/m3. Subsequently, based on the principle of air extraction and dust control, a negative pressure double extraction dust control system was constructed. The spatial and temporal evolution of wind flow and dust at different locations of the exhaust duct was investigated. When the exhaust duct A was 3.0 m away from the floor of the roadway, CA=3.0 m, and when the exhaust duct B was 4.0 m away from the left wall of the roadway, CB=4.0 m, the average dust concentrations at the driver's location, the front of the tunnel, and the back of the tunnel were 45.62, 164.58, and 5.21 mg/m3, respectively. Compared with single pressure-entry type ventilation, the dust prevention effect of the system improved by 86.55 %, 40.88 %, and 97.76 %, respectively, and this installation position was determined to be the optimal position for dust removal.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Ventilation control of tunnel drilling dust based on numerical simulation
    Jiang Zhong-an
    Wang Ya-peng
    Men Li-guo
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (05) : 1342 - 1356
  • [2] The influence of ventilation parameters on dust pollution in a tunnel?s environment using the CFD method
    Liu, Changqi
    Bao, Qiu
    Nie, Wen
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2022, 230
  • [3] Study on dust pollution characteristics and optimal dust control parameters during tunnel excavation by CFD simulation
    Hou, Chuangen
    Yu, Haiming
    Ye, Yuxi
    Yang, Xianhang
    Wang, Yuhuan
    Cheng, Weimin
    ADVANCED POWDER TECHNOLOGY, 2023, 34 (11)
  • [4] An assessment of the dust suppression performance of a hybrid ventilation system during the tunnel excavation process: Numerical simulation
    Cai, Xiaojiao
    Nie, Wen
    Yin, Shuai
    Liu, Qiang
    Hua, Yun
    Guo, Lidian
    Cheng, Lei
    Ma, Qingxin
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 152 : 304 - 317
  • [5] A study of the spray atomization and suppression of tunnel dust pollution based on a CFD-based simulation
    Guo, Cheng
    Nie, Wen
    Xu, Changwei
    Peng, Huitian
    Zhang, Chuanchang
    Li, Shenlong
    Yue, Ning
    Liu, Zhiqiang
    Yang, Shibo
    Ma, Qingxin
    Li, Minghui
    JOURNAL OF CLEANER PRODUCTION, 2020, 276
  • [6] A study on the dust control effect of the dust extraction system in TBM construction tunnels based on CFD computer simulation technology
    Liu, Qiang
    Nie, Wen
    Hua, Yun
    Jia, Lebin
    Li, Chongshan
    Ma, He
    Wei, Cunhou
    Liu, Changqi
    Zhou, Wenjie
    Peng, Huitian
    ADVANCED POWDER TECHNOLOGY, 2019, 30 (10) : 2059 - 2075
  • [7] Study of dust pollution control effect based on orthogonal test and CFD numerical simulations
    Nie W.
    Jiang C.
    Liu Q.
    Guo L.
    Zhang H.
    Cheng C.
    Zhu Z.
    Environmental Science and Pollution Research, 2024, 31 (31) : 43712 - 43730
  • [8] NUMERICAL SIMULATION OF THE YANMEN HIGHWAY TUNNEL WITH TWO VENTILATION SYSTEM CONTROLS
    He, Dejun
    Zhang, Quan
    Zhang, Guoqiang
    Fang, Biao
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 362 - 369
  • [9] Parts effect numerical simulation of longitudinal ventilation system of highway tunnel
    Wang, Y.D.
    Xia, Y.X.
    Xi'an Gonglu Jiaotong Daxue Xuebao/Journal of Xi'an Highway University, 2001, 21 (04):
  • [10] Numerical Simulation of Double Inlet Cylinder Cyclone Using CFD
    Ming, Yuan Xiao
    Jun, Zhao Hui
    Yi, Qu Jing
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 558 - +