6E evaluation of an innovative humidification dehumidification solar distiller unit: An experimental investigation

被引:0
|
作者
Abdullah, A. S. [1 ,2 ]
Elsayad, Mamoun M. [3 ]
Almoatham, Sulaiman [1 ]
Sharshir, Swellam W. [4 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Engn Al Kharj, Dept Mech Engn, Al Kharj 11942, Saudi Arabia
[2] Tanta Univ, Fac Engn, Mech Power Engn Dept, Tanta, Egypt
[3] Kafrelsheikh Univ, Inst Nanosci & Nanotechnol, Kafrelsheikh, Egypt
[4] Kafrelsheikh Univ, Fac Engn, Mech Engn Dept, Kafrelsheikh 33516, Egypt
关键词
Humidification dehumidification; Solar distiller; Air solar heater; Photovoltaic thermal; Copper chips; Packing material; 6E analysis; DESALINATION SYSTEM; PERFORMANCE EVALUATION; THERMAL PERFORMANCE; WATER; ENERGY; STILL; DESIGN; EXERGY; HDH;
D O I
10.1016/j.tsep.2024.103052
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work aims to enhance the productivity, efficiency, energy utilization, feasibility, and environmental outcomes of solar desalination systems via representing an innovative humidification dehumidification solar distillation unit coupled with a built-in air solar heater and photovoltaic thermal unit. The air solar heater was further improved by the incorporation of copper chips as thermal energy-storing materials for extending the desalination process during the sun's hours. Three distinct humidifier beds, including plastic waste (case A), wick materials (case B), and cellulose paper (case C) were tested and compared regarding system temperatures and hourly and daily drinkable water yield. Additionally, a 6E analysis was assessed and evaluated in terms of energy, exergy, economic, exergoeconomic, exergoenvironmental, and exergoenviroeconomic analysis for all the cases. According to the outcomes, the humidification dehumidification solar distiller with cellulose paper yielded the highest productivity and 6E outcomes where the daily drinkable water, thermal efficiency, and exergy efficiency were estimated as 7.78 L/m2, 73.45 %, and 5.3 %, outperforming the CSD by nearly 142.59 %, 144.02 %, and 229.19 %, respectively. Moreover, the price of drinkable water and the payback time decreased to 0.0099 $/L and 0.12 years, which represents a reduction of 68.27 % and 69.23 %, respectively, at an exergoeconomic factor of 4.19 kWh/$. Furthermore, the amount of CO2 reduced was increased to 3.92 tons, which is associated with earned credits of carbon of 56.78$. Finally, for this case, the HDH humidifier efficiency, dehumidifier effectiveness, and gain output ratio maximum and mean values were 96.66 and 84.5 %, 85.61 and 78.96 %, and 1.86 and 1.08, respectively.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Solar desalination using humidification dehumidification processes. Part II. A experimental investigation
    Nafey, AS
    Fath, HES
    El-Helaby, SO
    Soliman, A
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (7-8) : 1263 - 1277
  • [32] Thermal design of the humidification dehumidification desalination system: An experimental investigation
    Narayan, G. Prakash
    St John, Maximus G.
    Zubair, Syed M.
    Lienhard, John H., V
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 58 (1-2) : 740 - 748
  • [33] Performance evaluation of solar-assisted humidification dehumidification system for seawater desalination: An experimental approach
    Tiwari, Abhishek
    Kumar, Amit
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 356
  • [34] Experimental and numerical investigation of a solar-thermal humidification-dehumidification desalination plant for a coastal greenhouse
    Lotfi, Mohsen
    Mersch, Matthias
    Markides, Christos N.
    CLEANER ENGINEERING AND TECHNOLOGY, 2023, 13
  • [35] Mathematical modeling of a closed circulation solar desalination unit with humidification-dehumidification
    Yuan, Guofeng
    Zhang, Hefei
    DESALINATION, 2007, 205 (1-3) : 156 - 162
  • [36] Hybrid solar powered desalination system based on air humidification dehumidification integrated with novel distiller: Exergoeconomic analysis
    Kabeel, A. E.
    Diab, Mohamed R.
    Elazab, M. A.
    El-Said, Emad M. S.
    JOURNAL OF CLEANER PRODUCTION, 2022, 379
  • [37] Performance evaluation of a humidification-dehumidification unit integrated with wick solar stills under different operating conditions
    Abdullah, A. S.
    Essa, F. A.
    Omara, Z. M.
    Bek, M. A.
    DESALINATION, 2018, 441 : 52 - 61
  • [38] Experimental study of a humidification-dehumidification desalination system with heat pump unit
    Zhang, Yin
    Zhu, Chunguang
    Zhang, Huan
    Zheng, Wandong
    You, Shijun
    Zhen, Yuhan
    DESALINATION, 2018, 442 : 108 - 117
  • [39] 6E analyses of a new solar energy-driven polygeneration system integrating CO2 capture, organic Rankine cycle, and humidification-dehumidification desalination
    Khani, Nastaran
    Manesh, Mohammad H. Khoshgoftar
    Onishi, Viviani C.
    JOURNAL OF CLEANER PRODUCTION, 2022, 379
  • [40] Energy, exergy, environmental, and economic (4E's) analysis of a solar driven humidification-dehumidification desalination system: An experimental investigation
    Tiwari, Abhishek
    Kumar, Amit
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 47