Fast identification of internal and external faults of HVDC transmission line based on frequency spectrum correlation

被引:0
|
作者
School of Electrical and Information Engineering, Zhengzhou University of Light Industry, Dongfeng Road No.5, Zhengzhou [1 ]
450002, China
机构
来源
J. Electr. Syst. | 1600年 / 3卷 / 298-309期
基金
中国国家自然科学基金;
关键词
Dynamic permutation entropy - Eigen frequency spectrum - Eigenfrequency - External fault - Fourier's analysis - Frequency spectra - HVDC transmission lines - Internal faults - Permutation entropy - Similarity coefficients;
D O I
暂无
中图分类号
学科分类号
摘要
27
引用
收藏
相关论文
共 50 条
  • [1] Fast identification of internal and external faults of HVDC transmission line based on frequency spectrum correlation
    Li, Congshan
    Zhong, Pu
    He, Ping
    Yang, Guixian
    Ji, Yuqi
    JOURNAL OF ELECTRICAL SYSTEMS, 2021, 17 (03) : 298 - 309
  • [2] Fault Line Identification of HVDC Transmission Line by Frequency Spectrum Correlation Based on Capacitive-Coupling and Magnetic Field-Sensing
    Zhu, K.
    Lee, W.
    Pong, P.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,
  • [3] Identification Method for Internal and External Faults Based on Amplitude Feature of Backward Traveling Wave for HVDC Transmission I ine
    Li, Xiaopeng
    Lin, Sheng
    Jiang, Shuai
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1166 - 1169
  • [4] Fault-Line Identification of HVDC Transmission Lines by Frequency-Spectrum Correlation Based on Capacitive Coupling and Magnetic Field Sensing
    Zhu, Ke
    Lee, W. K.
    Pong, Philip W. T.
    IEEE TRANSACTIONS ON MAGNETICS, 2018, 54 (11)
  • [5] The Identification of Internal and External Faults for ±800kV UHVDC Transmission Line based on S-transform and SVM
    Shu Hongchun
    Tian Xincui
    Dai Yuetao
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 7138 - 7144
  • [6] Analysis of line faults on HVDC transmission system considering frequency-dependent parameters and HVDC control
    Xu, Min
    Cai, Zexiang
    Li, Xiaohua
    Zhao, Jianning
    Zhou, Quan
    Wang, Haijun
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (11): : 37 - 44
  • [7] A novel primary and backup relaying scheme considering internal and external faults in HVDC transmission lines
    Swetapadma, Aleena
    Agarwal, Shobha
    Abdelaziz, Almoataz Y. Y.
    Kotb, Hossam
    AboRas, Kareem M. M.
    Flah, Aymen
    Shouran, Mokhtar
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [8] The Identification of Internal and External Faults for ±800kV UHVDC Transmission Line based on using Wavelet Based Multi-Resolution Analysis
    Shu Hongchun
    Tian Xincui
    Dai Yuetao
    2010 2ND INTERNATIONAL WORKSHOP ON DATABASE TECHNOLOGY AND APPLICATIONS PROCEEDINGS (DBTA), 2010,
  • [9] ELECTROMAGNETIC INTERFERENCE DUE TO HVDC TRANSMISSION LINE FAULTS
    Yang, Yixin
    Ma, Jinxi
    Fortin, Simon
    Dawalibi, Farid
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [10] Research on the correlation between corona current spectrum and audible noise spectrum of HVDC transmission line
    Liu, Yingyi
    Zhou, Lijuan
    Liu, Yuanqing
    Yuan, Haiwen
    Ji, Liang
    PHYSICS OF PLASMAS, 2017, 24 (11)