Control Strategy for Neutral Point Voltage Stability of Auxiliary Resonant Commutated Pole Inverter

被引:0
|
作者
Wang X. [1 ]
Huang S. [1 ]
Zhou X. [1 ]
机构
[1] School of Automation Science and Engineering, South China University of Technology, Guangdong, Guangzhou
来源
Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science) | 2023年 / 51卷 / 03期
基金
中国国家自然科学基金;
关键词
active disturbance rejection control; auxiliary resonant commutated pole inverter; neutral point voltage; soft switching;
D O I
10.12141/j.issn.1000-565X.220496
中图分类号
学科分类号
摘要
Auxiliary resonant transform pole inverter (ARCP) has the advantages of high efficiency and low loss in high frequency and high power field. However, in practical application, the problem of neutral point voltage deviation will lead to the increase of failure rate of ARCP soft switch. In this paper, a neutral point voltage active disturbance rejection control strategy was proposed to solve the problem of neutral point voltage deviation of ARCP bus divider capacitor and the failure of zero voltage opening of main switch tube caused by neutral point voltage deviation. The influence of bus capacitor equivalent series resistance (ESR) on neutral point voltage and AC side voltage was analyzed, and a neutral point voltage model including bus capacitor ESR in variable sequential control mode was established. On this basis, the neutral point voltage active disturbance rejection controller was designed and the auxiliary tube was used to control the overcharge regulation time, which realize the current balance of the three-phase auxiliary branch resonant inductor, achieving the goal of neutral point voltage stability, zero voltage opening of the main switching tube and improving the efficiency of the inverter. Compared with 97. 0% inverter efficiency in PI control mode, active disturbance rejection control mode can achieve 97. 5% inverter efficiency at maximum power. The control strategy is easy to implement as it doesn’t need to change the circuit structure. The effectiveness of the proposed control strategy was verified by simulation and experimental results. © 2023 South China University of Technology. All rights reserved.
引用
收藏
页码:124 / 132and145
相关论文
共 23 条
  • [1] LI R., A ZVS grid-connected three-phase inverter [J], IEEE Transactions on Power Electronics, 27, 8, pp. 3595-3604, (2012)
  • [2] MCMURRAY W., Resonant snubbers with auxiliary switches [J], IEEE Transactions on Industry Applications, 29, 2, pp. 355-362, (1993)
  • [3] DONCKER R W D., The auxiliary resonant commutated pole converter, Proceedings of IEEE-IAS Meeting Record, pp. 1228-1235, (1990)
  • [4] LEE Y S, HAN B M, Auxiliary resonant commutated pole inverter with clamping diodes for voltage stress reduction across auxiliary switches, Proceedings of 2018 IEEE Region 10 Conference, pp. 394-398, (2018)
  • [5] GONG W K, A synchronous auxiliary resonant commutated pole soft switching inverter with improved load adaptability [J], IEEE Transactions on Power Electronics, 37, 3, pp. 3073-3084, (2022)
  • [6] CHARALAMBOUS A,, YUAN X,, MCNEILL N., High frequency EMI attenuation at source with the auxiliary commutated pole inverter [J]., IEEE Transactions on Power Electronics, 33, 7, pp. 5660-5676, (2018)
  • [7] MING Zhengfeng, NI Guangzheng, ZHOU Wenyun, Study of neutral-point voltage unbalancing problem in DC-rail ZVT inverter [J], Transactions of China Electrotechnical Society, 19, 5, pp. 81-86, (2004)
  • [8] A novel zero-voltage switching resonant pole inverter [C] ∥Proceedings of 2006 CES/IEEE 5th International Power Electronics and Motion Control Conference, pp. 1-5, (2006)
  • [9] Proceedings of 2009 13th European Conference on Power Electronics and Applications, pp. 1-8, (2009)
  • [10] WANG Qiang, Auxiliary resonant commutated pole inverter without change of neutral point potential, Proceedings of the Chinese Society of Electrical Engineering, 31, 18, pp. 27-32, (2011)