A Novel Exoskeleton Neuromuscular Interface Based on Motor Unit Action Potential Model Using High-Density sEMG

被引:0
作者
Wang, Weibo [1 ]
He, Long [2 ]
Wang, Jian [3 ]
Pan, Min [4 ]
Yi, Jingang [5 ]
Cheng, Ningtao [6 ]
Liu, Tao [1 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
[2] Zhiyuan Res Inst, Hangzhou 310024, Peoples R China
[3] Zhejiang Univ, Sports & Hlth Engn Inst, Sch Educ, Hangzhou 310058, Peoples R China
[4] Univ Bath, Dept Mech Engn, Bath BA2 7AY, England
[5] Rutgers State Univ, Dept Mech & Aerosp Engn, Piscataway, NJ 08854 USA
[6] Zhejiang Univ, Sch Med, Hangzhou 310058, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrodes; Motors; Sensors; Computational modeling; Neuromuscular; Analytical models; Skin; Layout; Accuracy; Exoskeletons; Electrode configuration; high-density surface electromyogram (HD-sEMG) modeling; high-density; microneedle electrode array; motor unit (MU); SURFACE EMG SIGNALS; ELECTRODE SIZE; DATA FUSION; SIMULATION; GENERATION;
D O I
10.1109/TIM.2024.3480235
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The topical and noninvasive measurement of high-density surface electromyogram (HD-sEMG) signals enables the estimation of human motor unit action potentials (MUAPs) as crucial motor function indicators for human-robot interaction. In this article, we present a 2-D high-density microneedle electrode array using the potassium hydroxide (KOH) bulk etching technique and the flexible printed circuit (FPC). To determine the optimal configuration of the 2-D electrode array, we propose an accurate and efficient neuromuscular analytical model for HD-sEMG that comprehensively analyzes the effects of the microneedle electrode size, interelectrode distance, and location. The experiment was conducted to demonstrate the feasibility and performance of the proposed microneedle-based high-density electrode array for the sEMG-based upper limb exoskeleton's elbow joint angle estimation, specifically in comparison to a commercial wet electrode. The experimental results showed that the proposed microneedle electrode with high spatial resolution was comparable to the wet electrode (Wilcoxon rank-sum test, $p \gt 0.05$ ). On average, the correlation and root-mean-squared error (RMSE) of the microneedle electrode array with high space utilization were 7.56% and 19.83% better than those of the wet electrode, respectively. The 2-D high-density microneedle electrode array based on the proposed HD-sEMG model facilitates a novel neural-machine interface for intuitive control of upper limb exoskeletons.
引用
收藏
页数:12
相关论文
共 41 条
  • [1] Two-dimensional surface EMG: The effects of electrode size, interelectrode distance and image truncation
    Afsharipour, B.
    Soedirdjo, S.
    Merletti, R.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 49 : 298 - 307
  • [2] Investigation of the HD-sEMG probability density function shapes with varying muscle force using data fusion and shape descriptors
    Al Harrach, Mariam
    Boudaoud, Sofiane
    Carriou, Vincent
    Laforet, Jeremy
    Letocart, Adrien J.
    Grosset, Jean-Francois
    Marin, Frederic
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 89 : 44 - 58
  • [3] Analysis of the sEMG/force relationship using HD-sEMG technique and data fusion: A simulation study
    Al Harrach, Mariam
    Carriou, Vincent
    Boudaoud, Sofiane
    Laforet, Jeremy
    Marin, Frederic
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 83 : 34 - 47
  • [4] Evaluation of muscle force classification using shape analysis of the sEMG probability density function: a simulation study
    Ayachi, F. S.
    Boudaoud, S.
    Marque, C.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (08) : 673 - 684
  • [5] Anatomically accurate model of EMG during index finger flexion and abduction derived from diffusion tensor imaging
    Botelho, Diego Pereira
    Curran, Kathleen
    Lowery, Madeleine M.
    [J]. PLOS COMPUTATIONAL BIOLOGY, 2019, 15 (08)
  • [6] MULTIELECTRODE STUDY OF THE TERRITORY OF A MOTOR UNIT
    BUCHTHAL, F
    GULD, C
    ROSENFALCK, P
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1957, 39 (01): : 83 - 104
  • [7] Speedup computation of HD-sEMG signals using a motor unit-specific electrical source model
    Carriou, Vincent
    Boudaoud, Sofiane
    Laforet, Jeremy
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2018, 56 (08) : 1459 - 1473
  • [8] Fast generation model of high density surface EMG signals in a cylindrical conductor volume
    Carriou, Vincent
    Boudaoud, Sofiane
    Laforet, Jeremy
    Ayachi, Fouaz Sofiane
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 74 : 54 - 68
  • [9] Finger Joint Angle Estimation Based on Motoneuron Discharge Activities
    Dai, Chenyun
    Hu, Xiaogang
    [J]. IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (03) : 760 - 767
  • [10] Precise and fast calculation of the motor unit potentials detected by a point and rectangular plate electrode
    Dimitrov, GV
    Dimitrova, NA
    [J]. MEDICAL ENGINEERING & PHYSICS, 1998, 20 (05) : 374 - 381