Computed Tomographic Characterization for Basivertebral Nerve Ablation Utilizing a Radiofrequency Multitined Expandable Electrode

被引:0
|
作者
Sayed, Dawood [1 ]
Beall, Douglas P. [2 ]
Gulati, Amitabh [3 ]
Hyman, Eric [4 ]
Block, Jon E.
机构
[1] KU Med Ctr, Kansas City, KS 66160 USA
[2] Comprehens Specialty Care, Edmond, OK USA
[3] Mem Sloane Kettering, New York, NY USA
[4] HaA Inc, Wakefield, MA USA
来源
MEDICAL DEVICES-EVIDENCE AND RESEARCH | 2024年 / 17卷
关键词
vertebrogenic pain; basivertebral nerve; endplate; radiofrequency ablation; Subsidio; electrode; back pain; INNERVATION PATTERNS; VERTEBROGENIC PAIN; DIAGNOSIS; SINGLE;
D O I
10.2147/MDER.S487201
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: A growing body of clinical evidence has demonstrated that intraosseous minimally invasive basivertebral nerve (BVN) ablation results in significant and durable improvements in vertebrogenic back pain. Thus, it is important to develop, refine and validate new and additional devices to accomplish this procedure. Methods: Using reconstructions of 31 patient computed tomography (CT) scans of the lumbosacral spine (L1-S1), the primary objective was to simulate the intravertebral placement of a novel multitined expandable electrode in bipolar configuration at the targeted ablation site and determine if the proper trajectories could be achieved in order for the device tips to be in the correct position for lesion formation at the BVN plexus. Successful device deployment required that the distance between tips was between 10 mm and 20 mm. Results: The mean distances between device tips ranged from 11.35 mm (L5) to 11.87 mm (L3), and there were no statistically significance differences across the six vertebral levels (F = 0.72, p = 0.61). The percentage of successful intraosseous device placements within the tip distance acceptable range (>= 10 mm to <= 20 mm) was 90% (162 of 180), with no tip-to-tip distances > 20 mm. There was a notable association between decreasing vertebral level and mean degree of angulation between contralateral devices ranging from 50.90 degrees at L1 to 91.51 degrees at S1, and the difference between across the six vertebral levels was significant (F = 89.5, p < 0.01). Conclusion: Feasibility evidence is provided from real world CT imaging data that validates using the multitined electrode for proper intraosseous placement within the vertebral body to effectively ablate the BVN plexus.
引用
收藏
页码:323 / 337
页数:15
相关论文
共 23 条
  • [21] Computed Tomographic-Guided Radiofrequency Ablation of Recurrent or Residual Hepatocellular Carcinomas around Retained Iodized Oil, after Transarterial ChemoemboLization
    Koh, Young Hwan
    Choi, Joon-Il
    Kim, Hyun Beom
    Kim, Min Ju
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (05) : 733 - 742
  • [22] Genicular Nerve Radiofrequency Ablation for Chronic Knee Pain Using a Three-Tined Electrode: A Technical Description and Case Series
    Koshi, Edvin
    Cheney, Cole W.
    Sperry, Beau P.
    Conger, Aaron
    McCormick, Zachary L.
    PAIN MEDICINE, 2020, 21 (12) : 3344 - 3349
  • [23] Characterization of the dynamic function of the pulmonary veins before and after atrial fibrillation ablation using multi-detector computed tomographic images
    Tsao, Hsuan-Ming
    Hu, Wei-Chih
    Wu, Mei-Han
    Tai, Ching-Tai
    Chang, Shih-Lin
    Lin, Yenn-Jiang
    Lo, Li-Wei
    Hu, Yu-Feng
    Wu, Tsu-Juey
    Sheu, Ming-Huei
    Chang, Cheng-Yen
    Chen, Shih-Ann
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1049 - 1058