Experimental study on improving effect of cooling garment on thermal comfort and salivary IgA concentration

被引:0
|
作者
Lin, Huxiang [1 ]
Wang, Haiying [1 ]
Yan, Renjie [1 ]
Sun, Junli [1 ]
Meng, Hang [1 ]
Hu, Songtao [1 ]
机构
[1] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Phase change cooling garments; Thermal comfort; Skin temperature; Salivary immunoglobulin A; VENTILATION SYSTEM; IMMUNOGLOBULIN-E; HUMID CLIMATE; TEMPERATURE; RESPONSES; COLD; HOT; AIR; THERMOREGULATION; ENVIRONMENTS;
D O I
10.1016/j.enbuild.2024.114970
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Phase change cooling garments (PCCGs) can effectively alleviate the heat stress of manual workers in high-temperature environments. The PCCGs bring about cold stimuli to users, which not only affect the thermal perception and thermoregulation of the human body, but also could have some influence on the nervous and endocrine system, and even on the immune system. This study explores the effects of PCCGs on thermal comfort and respiratory mucosal immune function. Experiments were conducted in a climate chamber at 33 degrees C with a relative humidity of 50 %. Twenty participants were recruited and experienced three experimental conditions (NG, normal garments; PCCGs with a cooling temperature of 21 degrees C, PCCGs-21 and 17 degrees C, PCCGs-17). Subjects took packing activity with a metabolic rate of around 2.7 met. Subjective questionnaires (thermal sensation votes, thermal comfort votes) were collected, and physiological parameters (skin temperature, core temperature) were tested. Besides, the salivary samples were gathered to measure the Salivary secretory immunoglobulin A (S-IgA) concentrations using enzyme-linked immunosorbent assay (ELISA). The results showed that the use of PCCGs affected the S-IgA concentration significantly. Compared with the NG condition, the S-IgA concentrations increased by 55.9 % and 46.4 % in the PCCGs-21 and PCCGs-17 conditions, respectively. Additionally, the S-IgA concentrations were the highest when participants felt slightly warm or comfortable. The S-IgA concentration of the comfortable state was 98.5 % higher than that of the intolerable state. The S-IgA concentrations were also found to be negatively correlated with local skin temperatures of the back and chest (p < 0.001). The use of PCCGs has a positive influence on improving thermal comfort and S-IgA concentration.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Study on the Effect of TPR Simulated Skin on Water Cooling Garment
    Yang, Kai
    Jiao, Mingli
    Zhang, Weiyuan
    PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 2554 - +
  • [22] Experimental Study of Thermal Comfort Based on Driver Physiological Signals in Cooling Mode under Summer Conditions
    Shin, Yunchan
    Ham, Jeonggyun
    Cho, Honghyun
    APPLIED SCIENCES-BASEL, 2021, 11 (02): : 1 - 19
  • [23] Thermal comfort and heat flow characteristics of hybrid cooling systems for studio type classrooms: An experimental study
    Chandrashekar, Rakesh
    Pai, Ananth
    Vivek, T.
    Sekar, S. K.
    Arici, Muslum
    Balaji, K.
    ENERGY AND BUILDINGS, 2024, 316
  • [24] Thermal comfort of a radiant cooling system in glass fiber reinforced gypsum roof-An experimental study
    Dharmasastha, K.
    Samuel, D. G. Leo
    Nagendra, S. M. Shiva
    Maiya, M. P.
    APPLIED THERMAL ENGINEERING, 2022, 214
  • [25] Modelling of human thermal comfort in armored military vehicles: An experimental study of removing heat with spot cooling
    Dibek, Burak
    Agra, Ozden
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49
  • [26] Impact of indoor heat load and natural ventilation on thermal comfort of radiant cooling system: An experimental study
    Dharmasastha K.
    Samuel D.G.L.
    Nagendra S.M.S.
    Maiya M.P.
    Energy and Built Environment, 2023, 4 (05): : 543 - 556
  • [27] Thermal comfort assessment and application of radiant cooling: A case study
    Memon, Rizwan Ahmed
    Chirarattananon, Surapong
    Vangtook, Prapapong
    BUILDING AND ENVIRONMENT, 2008, 43 (07) : 1185 - 1196
  • [28] Experimental Study on Thermal Comfort with Radiant Cooling Workstation and Desktop Fan in Hot-humid Environment
    Li N.
    He D.
    He Y.
    He M.
    Zhang W.
    Li, Nianping (linianping@126.com), 1600, Hunan University (44): : 198 - 204
  • [29] A field study of occupant thermal comfort and thermal environments with radiant slab cooling
    Tian, Zhen
    Love, James A.
    BUILDING AND ENVIRONMENT, 2008, 43 (10) : 1658 - 1670
  • [30] Outdoor thermal comfort and the cooling effect in different layouts of shaded spaces: A study of Guangzhou, China
    Feng, Tangjun
    Peng, Ran
    ENERGY AND BUILDINGS, 2025, 331