An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System

被引:0
作者
Shurche, Sadegh [1 ]
Sooteh, Mohammad Yousefi [2 ]
机构
[1] Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran
[2] Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz
关键词
Anthropomorphic Head; Geometric Distortion; High-field MRI; Phantom;
D O I
10.22038/IJMP.2023.37141.1469
中图分类号
学科分类号
摘要
Introduction: Our goal is to design and construct a new anthropomorphic head phantom for assessment of image distortion in treatment planning systems. Material and Methods: In this study, CT scan images of heads were transferred to the Mimic software. Using this software, the skull texture was removed and a hollow layer was formed between the bone tissues, in which the bone tissue would be equivalent to the material. Then it was fabricated with a 3D printer using K2HPO4 (as bone). A new phantom containing 8, 000 reference features (control points) with AutoCAD software designed, fabricated it with a 3D printer and filled it with gels that included nickel-doped agarose, urea, and sodium chloride (as soft tissue) and then placed this grid inside the head phantom. This phantom was tested on the Siemens 3 Tesla Prisma MRI model using a 64-channel head coil. In this regard, a three-dimensional reference model was used. Reproducibility on the phantom was investigated with three different imaging sessions per day for three different days. Results: T2 gel value, 84.804 ± 3ms was obtained for gel that simulates brain tissue. In addition, their corresponding T1 measurements were 1090.92 (ms), respectively. By Adding nickel to agarose gels, the amount of CT number in all energies of 80 to 130 kVp increased. Increasing the concentration of nickel in gels results in a decrease in CT number. The geometric distortion in the 3D results was found to be due to field non-uniformity and nonlinearity of the gradients and its reproducibility. Conclusion: The results show that, the amount of distortion in the middle of the field was less than that of its sides. This phantom can be used to check image distortion in treatment planning systems. © (2024), (Mashhad University of Medical Sciences). All rights reserved.
引用
收藏
页码:53 / 63
页数:10
相关论文
共 50 条
  • [41] Method for a detailed measurement of image intensity nonuniformity in magnetic resonance imaging
    Wang, DM
    Doddrell, DM
    MEDICAL PHYSICS, 2005, 32 (04) : 952 - 960
  • [42] Distortion Correction Protocol for 3T Stereotactic Magnetic Resonance Imaging: A Clinical Study
    Tavares, Wagner Malago
    Tustumi, Francisco
    Leite, Claudia da Costa
    Gamarra, Lionel Fernel
    Amaro Junior, Edson
    Texeira, Manoel Jacobsen
    de Franca, Sabrina Araujo
    Fonoff, Erich Talamoni
    WORLD NEUROSURGERY, 2019, 122 : E690 - E699
  • [43] Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system
    Tao, S.
    Trzasko, J. D.
    Gunter, J. L.
    Weavers, P. T.
    Shu, Y.
    Huston, J., III
    Lee, S. K.
    Tan, E. T.
    Bernstein, M. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02) : N18 - N31
  • [44] Prostate magnetic resonance imaging (MRI) in patients with hip implants-presetting a protocol using a phantom
    Vasilev, Yuriy A.
    Panina, Olga Yu.
    Semenov, Dmitry S.
    Akhmad, Ekaterina S.
    Sergunova, Kristina A.
    Kivasev, Stanislav A.
    V. Petraikin, Alexey
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (10) : 7128 - 7137
  • [45] Development of a standard phantom for diffusion-weighted magnetic resonance imaging quality control studies: A review
    Manson, Eric Naab
    Mumuni, Abdul Nashirudeen
    Shirazu, Issahaku
    Hasford, Francis
    Inkoom, Stephen
    Sosu, Edem
    Aikins, Mark Pokoo
    Mohammed, Gedel Ahmed
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (04): : 169 - 179
  • [46] Phantom study investigating the repeatability of radiomic features with alteration of image acquisition parameters in magnetic resonance imaging
    Mitchell-Hay, Rosalind
    Ahearn, Trevor
    Murray, Alison
    Waiter, Gordon
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2024, 55 (01) : 19 - 28
  • [47] Analisys of Measurement Methods for Static Magnetic Field Uniformity Assessment in Clinical Magnetic Resonance Imaging
    Verducci, Giovanni
    Silvestri, Sergio
    Mirarchi, Luciano
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 625 - 630
  • [48] Accuracy of cardiac-induced brain motion measurement using displacement-encoding with stimulated echoes (DENSE) magnetic resonance imaging (MRI): A phantom study
    Nwotchouang, Blaise Simplice Talla
    Eppelheimer, Maggie S.
    Biswas, Dipankar
    Pahlavian, Soroush Heidari
    Zhong, Xiaodong
    Oshinski, John N.
    Barrow, Daniel L.
    Amini, Rouzbeh
    Loth, Francis
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1237 - 1247
  • [49] Evaluating the repeatability and set-up sensitivity of a large field of view distortion phantom and software for magnetic resonance-only radiotherapy
    Wyatt, Jonathan
    Hedley, Stephen
    Johnstone, Emily
    Speight, Richard
    Kelly, Charles
    Henry, Ann
    Short, Susan
    Murray, Louise
    Sebag-Montefiore, David
    McCallum, Hazel
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 31 - 38
  • [50] Quality assurance measurements of geometric accuracy for magnetic resonance imaging-based radiotherapy treatment planning
    Ranta, Iiro
    Kemppainen, Reko
    Keyrilainen, Jani
    Suilamo, Sami
    Heikkinen, Samuli
    Kapanen, Mika
    Saunavaara, Jani
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 62 : 47 - 52