An Anthropomorphic Head Phantom Prototype for the Measurement of Geometric Distortion in Magnetic Resonance Imaging System

被引:0
作者
Shurche, Sadegh [1 ]
Sooteh, Mohammad Yousefi [2 ]
机构
[1] Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, Tehran
[2] Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz
关键词
Anthropomorphic Head; Geometric Distortion; High-field MRI; Phantom;
D O I
10.22038/IJMP.2023.37141.1469
中图分类号
学科分类号
摘要
Introduction: Our goal is to design and construct a new anthropomorphic head phantom for assessment of image distortion in treatment planning systems. Material and Methods: In this study, CT scan images of heads were transferred to the Mimic software. Using this software, the skull texture was removed and a hollow layer was formed between the bone tissues, in which the bone tissue would be equivalent to the material. Then it was fabricated with a 3D printer using K2HPO4 (as bone). A new phantom containing 8, 000 reference features (control points) with AutoCAD software designed, fabricated it with a 3D printer and filled it with gels that included nickel-doped agarose, urea, and sodium chloride (as soft tissue) and then placed this grid inside the head phantom. This phantom was tested on the Siemens 3 Tesla Prisma MRI model using a 64-channel head coil. In this regard, a three-dimensional reference model was used. Reproducibility on the phantom was investigated with three different imaging sessions per day for three different days. Results: T2 gel value, 84.804 ± 3ms was obtained for gel that simulates brain tissue. In addition, their corresponding T1 measurements were 1090.92 (ms), respectively. By Adding nickel to agarose gels, the amount of CT number in all energies of 80 to 130 kVp increased. Increasing the concentration of nickel in gels results in a decrease in CT number. The geometric distortion in the 3D results was found to be due to field non-uniformity and nonlinearity of the gradients and its reproducibility. Conclusion: The results show that, the amount of distortion in the middle of the field was less than that of its sides. This phantom can be used to check image distortion in treatment planning systems. © (2024), (Mashhad University of Medical Sciences). All rights reserved.
引用
收藏
页码:53 / 63
页数:10
相关论文
共 50 条
  • [1] A novel phantom and method for comprehensive 3-dimensional measurement and correction of geometric distortion in magnetic resonance imaging
    Wang, DM
    Doddrell, DM
    Cowin, G
    MAGNETIC RESONANCE IMAGING, 2004, 22 (04) : 529 - 542
  • [2] Geometric Distortion in Structural Magnetic Resonance Imaging
    Wang, Deming
    Doddrell, David M.
    CURRENT MEDICAL IMAGING REVIEWS, 2005, 1 (01) : 49 - 60
  • [3] Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes
    Rostami, A.
    Naseri, Sh
    Momennezhad, M.
    Zare, H.
    Anvari, K.
    Badkhor, H. R. Sayah
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (04): : 733 - 742
  • [4] Audit feasibility for geometric distortion in magnetic resonance imaging for radiotherapy
    Alzahrani, Meshal
    Broadbent, David A.
    Chuter, Robert
    Al-Qaisieh, Bashar
    Jackson, Steven
    Michael, Hutton
    Johnstone, Robert, I
    Shah, Simon
    Wetscherek, Andreas
    Chick, H. Joan
    Wyatt, Jonathan J.
    McCallum, Hazel Mhairi
    Speight, Richard
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 15 : 80 - 84
  • [5] A standard system phantom for magnetic resonance imaging
    Stupic, Karl F.
    Ainslie, Maureen
    Boss, Michael A.
    Charles, Cecil
    Dienstfrey, Andrew M.
    Evelhoch, Jeffrey L.
    Finn, Paul
    Gimbutas, Zydrunas
    Gunter, Jeffrey L.
    Hill, Derek L. G.
    Jack, Clifford R.
    Jackson, Edward F.
    Karaulanov, Todor
    Keenan, Kathryn E.
    Liu, Guoying
    Martin, Michele N.
    Prasad, Pottumarthi, V
    Rentz, Nikki S.
    Yuan, Chun
    Russek, Stephen E.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) : 1194 - 1211
  • [6] A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom
    Wang, DM
    Doddrell, DM
    MEDICAL PHYSICS, 2004, 31 (08) : 2212 - 2218
  • [7] Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging
    Torfeh, Tarraf
    Hammoud, Rabih
    McGarry, Maeve
    Al-Hammadi, Noora
    Perkins, Gregory
    MAGNETIC RESONANCE IMAGING, 2015, 33 (07) : 939 - 949
  • [8] Evaluation of Spatial-encoding-related Geometric Distortion in Magnetic Resonance Imaging
    Hong, Cheol Pyo
    Lee, Dong Hoon
    Lee, Man Woo
    Woo, Youngkeun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (12) : 2068 - 2072
  • [9] Phantom-based characterization of distortion on a magnetic resonance imaging simulator for radiation oncology
    Huang, Ke
    Cao, Yue
    Baharom, Umar
    Balter, James M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02) : 774 - 790
  • [10] Evaluation of spatial-encoding-related geometric distortion in magnetic resonance imaging
    Cheol Pyo Hong
    Dong Hoon Lee
    Man Woo Lee
    Youngkeun Woo
    Journal of the Korean Physical Society, 2012, 61 : 2068 - 2072