Novel and simple electrochemical sensing platform based on polypyrrole nanotubes/ZIF-67 nanocomposite/screen printed graphite electrode for sensitive determination of metronidazole

被引:7
作者
Tajik, Somayeh [1 ]
Beitollahi, Hadi [2 ]
Nejad, Fariba Garkani [2 ]
机构
[1] Kerman Univ Med Sci, Res Ctr Trop & Infect Dis, Kerman, Iran
[2] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
关键词
Metronidazole; Screen printed graphite electrode; Polypyrrole nanotubes/ZIF-67; Voltammetry; METAL-ORGANIC-FRAMEWORKS; WALLED CARBON NANOTUBES; SENSOR; NANOPARTICLES; EFFICIENT; FABRICATION; SEPARATION; CATECHOL;
D O I
10.1016/j.elecom.2024.107824
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Here, a simple, fast, and sensitive voltammetric sensor based on screen printed graphite electrode (SPGE) modified with polypyrrole nanotubes/zeolitic imidazolate framework-67 (PPy NTs/ZIF-67) nanocomposite is introduced for the metronidazole (MNZ) determination. The PPy NTs/ZIF-67 nanocomposite was synthesized and characterized by using X-ray diffraction (XRD) spectroscopy, field emission scanning electron microscopy (FE-SEM), and energy-dispersive X-ray spectroscopy (EDS) techniques. The developed sensor based on PPy NTsZIF-67 nanocomposite modified SPGE shows an obvious reduction peak at-650 mV for MNZ, mainly due to the synergistic effects of the ZIF-67 and PPy NTs. Differential pulse voltammetry (DPV) was found to be the most suitable method for MNZ detection, showing a linear dynamic range of 0.01-500.0 mu M and a low limit of detection (LOD) of 0.004 mu M. In investigating the practicability, the PPy NTs/ZIF-67/SPGE sensor demonstrated efficient practicability with satisfactory recoveries (97.1 % to 103.5 %) and low relative standard deviation (RSD) values of 1.8-3.6 % for MNZ determination in MNZ tablets and urine samples.
引用
收藏
页数:8
相关论文
共 85 条
[21]   Simultaneous detection of Lead and Cadmium using a composite of Zeolite Imidazole Framework and Reduced Graphene Oxide (ZIF-67/rGO) via electrochemical approach [J].
Garg, Naini ;
Deep, Akash ;
Sharma, Amit L. .
ENVIRONMENTAL ENGINEERING RESEARCH, 2023, 28 (04)
[22]   Voltammetric determination of oxytetracycline in milk and pharmaceuticals samples using polyurea modified glassy carbon electrode [J].
Gashu, Mulu ;
Aragaw, Belete Asefa ;
Tefera, Molla .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2023, 117
[23]   Cadmium sulfide quantum dots anchored on reduced graphene oxide for the electrochemical detection of metronidazole [J].
Gopi, Praveen Kumar ;
Kesavan, Ganesh ;
Chen, Shen-Ming ;
Ravikumar, Chandan Hunsur .
NEW JOURNAL OF CHEMISTRY, 2021, 45 (06) :3022-3033
[24]   Controlling ZIF-67 crystals formation through various cobalt sources in aqueous solution [J].
Guo, Xiangli ;
Xing, Tiantian ;
Lou, Yongbing ;
Chen, Jinxi .
JOURNAL OF SOLID STATE CHEMISTRY, 2016, 235 :107-112
[25]   Simple and affordable graphene nano-platelets and carbon nanocomposite surface decorated with cetrimonium bromide as a highly responsive electrochemical sensor for rutin detection [J].
Hareesha, N. ;
Manjunatha, J. G. ;
Alothman, Zeid A. ;
Sillanpaa, Mika .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 917
[26]  
Ceruelos AH, 2019, EUR REV MED PHARMACO, V23, P397, DOI 10.26355/eurrev_201901_16788
[27]   Determination of dimetridazole and metronidazole in poultry and porcine tissues by gas chromatography-electron capture negative ionization mass spectrometry [J].
Ho, C ;
Sin, DWM ;
Wong, KM ;
Tang, HPO .
ANALYTICA CHIMICA ACTA, 2005, 530 (01) :23-31
[28]   Electrochemical Determination of Diclofenac by Using ZIF-67/g-C3N4 Modified Electrode [J].
Hoa, Dang Thi Ngoc ;
Tu, Nguyen Thi Thanh ;
Son, Le Van Thanh ;
Son, Le Vu Truong ;
Toan, Tran Thanh Tam ;
Thong, Pham Le Minh ;
Nhiem, Dao Ngoc ;
Lieu, Pham Khac ;
Khieu, Dinh Quang .
ADSORPTION SCIENCE & TECHNOLOGY, 2021, 2021
[29]   Preparation of magnetic Fe3O4/PPy@ZIF-8 nanocomposite for glucose oxidase immobilization and used as glucose electrochemical biosensor [J].
Hou, Chen ;
Zhao, Dongyan ;
Wang, Yang ;
Zhang, Sufeng ;
Li, Shuangyang .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 822 :50-56
[30]   Kinetic spectrophotometric H-point standard addition method for the simultaneous determination of diloxanide furoate and metronidazole in binary mixtures and biological fluids [J].
Issa, Mahmoud Mohamed ;
Nejem, R'afat Mahmoud ;
Abu Shanab, Alaa Mohamed ;
Shaat, Nahed Talab .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2013, 114 :592-598