Direct Transient Stability Assessment of Grid-Connected Voltage Source Converters: A Transient Energy Functions Perspective

被引:0
|
作者
Poulose, Albert [1 ]
Kim, Soobae [1 ]
机构
[1] Kyungpook Natl Univ, Sch Elect & Elect Engn, Dept Elect Engn, Daegu 41566, South Korea
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Power system stability; Transient analysis; Stability criteria; Numerical stability; Grid forming; Grid following; Voltage control; Lyapunov methods; Renewable energy sources; Direct transient stability; grid-forming; grid-following; Lyapunov functions; power system stability; transient stability; transient energy functions; renewable penetrated systems; voltage source converters; VIRTUAL SYNCHRONOUS GENERATORS; POWER-SYSTEMS; SYNCHRONIZATION;
D O I
10.1109/ACCESS.2024.3450316
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The integration of renewable energy sources ( RES ) into the grid predominantly utilizes voltage source converters ( VSC ) with a grid-following ( GFL ) connection strategy. This approach, however, often faces instability issues in low-inertia grid regions. To enhance grid resilience in renewable-dominated power systems, grid-forming ( GFM ) connection strategies have been introduced, with the virtual synchronous machine ( VSM ) technique based on GFM control being particularly prevalent. Consequently, transient stability investigations of power systems employing both GFL and GFM connection techniques have gained increasing relevance. This paper proposes an innovative fast direct transient stability analysis ( DTSA ) approach that leverages Lyapunov's direct method to assess the transient stability of a GFM with VSM control technique, incorporating the influence of parallel-connected VSC with GFL control strategy. The proposed DTSA approach models the GFL as a current source with parallel internal reactance and the GFM as a voltage source with series internal reactance. Detailed analytical derivations of the DTSA approach using transient energy functions, along with the DTSA criterion for the interconnected system, are presented to determine the critical clearing time ( CCT ) of the GFM-employed VSC. . Furthermore, Matlab/Simulinkbased electromagnetic transient ( EMT ) time-domain ( t - d) ) simulation responses are utilized to validate the accuracy and computational effectiveness of the proposed fast DTSA approach. In addition, the proposed DTSA approach offers considerable benefits for efficiently assessing and managing power systems that heavily rely on RES in terms of operational planning and contingency management.
引用
收藏
页码:133545 / 133556
页数:12
相关论文
共 50 条
  • [31] Loop-at-a-Time Stability Analysis for Grid-Connected Voltage-Source Converters
    Zhang, Hongyang
    Harnefors, Lennart
    Wang, Xiongfei
    Hasler, Jean-Philippe
    Ostlund, Stefan
    Danielsson, Christer
    Gong, Hong
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2021, 9 (05) : 5807 - 5821
  • [32] The Analytical Switching Modelling Method of Grid-Connected Converters for Transient Stability Analysis
    Ding, Wenze
    Geng, Hua
    Ren, Bixing
    Li, Qiang
    Sun, Rong
    2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 287 - 293
  • [33] Transient Stability Assessment of Large Scale Grid-Connected Photovoltaic on Transmission System
    Zainuddin, Muammar
    Handayani, T. P.
    Sarjiya
    Sunanda, Wahri
    Surusa, Frengki Eka Putra
    PROCEEDINGS OF 2018 2ND INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA), 2018, : 113 - 118
  • [34] Transient Current Calculation of Grid-Connected Converters under Grid Faults
    Liu, Li
    Dai, Tao
    Huang, Meng
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 310 - 314
  • [35] Stability Constrained Transient Overcurrent Capability Enhancement of Grid Forming Converters Based on Switching Frequency Adjustment
    Liu, Boxin
    Xiang, Xin
    Li, Yonghao
    Yang, Huan
    Li, Wuhua
    He, Xiangning
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (02) : 2987 - 3004
  • [36] Transient stability analysis of a grid-connected type-4 wind turbine with grid-forming control during the fault
    Gao, Zhen
    Du, Wenjuan
    Wang, H. F.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [37] A simulation method of grid-connected wind farm on transient stability
    Han, Xiaoning
    Lei, Qiaohong
    Shi, Yan
    Han, Xiaoqing
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 955 - +
  • [38] Transient Stability Analysis of Grid-Connected Converters in Wind Turbine Systems Based on Linear Lyapunov Function and Reverse-Time Trajectory
    Bakhshizadeh, Mohammad Kazem
    Ghosh, Sujay
    Yang, Guangya
    Kocewiak, Lukasz
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2024, 12 (03) : 782 - 790
  • [39] Dynamic Current Limiting of Grid-Forming Converters for Transient Synchronization Stability Enhancement
    Liu, Yushuang
    Geng, Hua
    Huang, Meng
    Zha, Xiaoming
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2024, 60 (02) : 2238 - 2248
  • [40] Effects of Virtual Resistance on Transient Stability of Virtual Synchronous Generators Under Grid Voltage Sag
    Xiong, Xiaoling
    Wu, Chao
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (05) : 4754 - 4764