Comprehensive Modeling and Analysis of Stator Turn-to-Turn Short-Circuit Faults in a DFIG

被引:0
|
作者
Yan, Chenguang [1 ]
Wang, Weixiang [1 ]
Liu, Qinzhi [1 ]
Liu, Zhangheng [1 ]
Shu, Jin [2 ]
Zhao, Jikai [2 ]
Zhang, Baohui [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
[2] Xian Thermal Power Res Inst Co Ltd, Power Util Tech Supervis Dept, Xian 710054, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Circuit faults; Doubly fed induction generators; Stator windings; Windings; Resistance; Integrated circuit modeling; Mathematical models; Arc resistance; doubly fed induction generator; field-circuit coupling model; stator turn-to-turn short-circuit fault; DIAGNOSIS;
D O I
10.1109/TASC.2024.3463255
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the gradual increase in high capacity doubly fed induction generators (DFIGs) in recent years, turn-to-turn short-circuit (TTSC) faults have become a greater threat. Notably, owing to the absence of an effective fault model, the specific TTSC fault behaviors of DFIGs remain to be clarified. This study proposes a comprehensive field-circuit coupling model of stator TTSC faults inside a DFIG, which captures a two-way interaction between the circuit and field domains. Meanwhile, the control strategy for DFIG back-to-back converters is also considered in this computational model. Moreover, the nonlinear resistance of the fault arc is simultaneously calculated by using a black box model in the circuit domain. A 1.5 MW DFIG with its control system was modeled and simulated to suffer a series of TTSC faults. Fault features, including the distributions of magnetic flux density, short-circuit currents, and terminal behaviors, were revealed, and the influencing factors regarding the fault types, severities and locations were discussed. The proposed comprehensive model and the derived characteristic signatures provide insights into the development of sensitive and reliable relay protection schemes for TTSC faults in DFIGs and are expected to promote subsequent research on fault detection and diagnosis in electric machinery controlled by power electronics.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Asynchronous motor stator turn-to-turn short circuit fault diagnosis based on d - q transform and WOA-LSTM
    Wang, Xilian
    Qin, Jiayi
    Geng, Min
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2024, 28 (06): : 56 - 65
  • [42] Inter-turn Short-circuit Fault Identification of Stator Winding for Offshore DFIG Based on Positive Sequence Impedance Angle
    Wei S.
    Wu R.
    Fu Y.
    Wang J.
    Zhou B.
    Ren H.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (12): : 165 - 171
  • [43] Experiment Research and Analysis of Stator Winding Short Circuit Faults in DFIG
    Zhao, Yihan
    Chen, Yu
    Wang, Lulu
    Ur Rehman, Attiq
    Yin, Yonghong
    Cheng, Yonghong
    Tanaka, Toshikatsu
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 160 - 163
  • [44] A Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults
    Qi, Yuan
    Bostanci, Emine
    Gurusamy, Vigneshwaran
    Akin, Bilal
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (12) : 10784 - 10793
  • [45] Classification of inter-turn short-circuit faults in induction motors based on quaternion analysis
    Cardenas-Cornejo, Juan-Jose
    Ibarra-Manzano, Mario-Alberto
    Gonzalez-Parada, Adrian
    Castro-Sanchez, Rogelio
    Almanza-Ojeda, Dora-Luz
    MEASUREMENT, 2023, 222
  • [46] Calculation and analysis of three-dimensional model for turn-to-turn short circuit of high voltage reactor
    Wu S.
    Ma H.
    Wei X.
    Chen X.
    Xu H.
    Liu B.
    Song K.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (04): : 148 - 154
  • [47] Fault Detection of Stator Inter-Turn Short-Circuit in PMSM on Stator Current and Vibration Signal
    Liang, Hong
    Chen, Yong
    Liang, Siyuan
    Wang, Chengdong
    APPLIED SCIENCES-BASEL, 2018, 8 (09):
  • [48] Transient envelope current analysis for inter-turn short-circuit detection in induction motor stator
    Isabela Oliveira Zaparoli
    Lane Maria Rabelo Baccarini
    Paulo Cezar Monteiro Lamim Filho
    Fabiano Bianchini Batista
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [49] Thermal Analysis of an Induction Motor Subjected to Inter-Turn Short-Circuit Failures in the Stator Windings
    Muxiri, Ananias C. P.
    Bento, Fernando
    Fonseca, D. S. B.
    Marques Cardoso, Antonio J.
    2019 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2019,
  • [50] Analysis on stator current harmonics characteristics with rotor winding inter-turn short circuit fault in DFIG
    Wang, Dong, 1600, Automation of Electric Power Systems Press (38):