Characterizing pediatric head patient size in Moroccan population: Establishing age-dependent relationships for accurate CT dose estimation

被引:8
|
作者
Sekkat, H. [1 ]
Elmansouri, K. [1 ]
Khallouqi, A. [1 ]
Halimi, A. [1 ]
El Rhazouani, O. [1 ]
Tahiri, Z. [2 ]
Talbi, M. [3 ]
El Mansouri, M. [4 ]
机构
[1] Hassan First Univ, Higher Inst Hlth Sci, Lab Sci & Hlth Technol, Settat, Morocco
[2] Abdelmalek Essaadi Univ, Fac Med & Pharm, Biophys Lab, Life & Hlth Sci Res Lab, Tangier, Morocco
[3] Moulay Ismail Univ, Fac Sci, Phys Sci & Engn, Zitoune Meknes, Morocco
[4] Ibn Tofail Univ, Fac Sci, Dept Phys, Lab Mat & Subatom Phys, Kenitra, Morocco
关键词
pediatric head CT; effective diameter; water-equivalent diameter; SSDE; COMPUTED-TOMOGRAPHY; BODY-SIZE;
D O I
10.1051/radiopro/2024017
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurate dose estimation in computed tomography (CT) scans is crucial and relies on precise normalization of output dose, typically measured by the volume CT dose index (CTDIvol). Key metrics, including effective diameter (Deff) and water-equivalent diameter (Dw), play pivotal roles in characterizing patient size. However, a notable gap exists in delineating the specific relationships between age and head patient size (Deff and Dw) for pediatric patients in Morocco. The primary objective of this study was to establish these critical associations between patient age and head patient size (Deff and Dw), providing a foundation for calculating size-specific dose estimates (SSDE) in pediatric head CT examinations. A retrospective analysis of data from 134 pediatric patients, aged 0-13 yr, comprising 71 males and 63 females who underwent head CT scans, was conducted. Utilizing the Radiant DICOM Viewer, patient sizes were measured in terms of both lateral and anterior-posterior dimensions for Deff and Dw calculations based on CT images in DICOM format. Our analysis revealed robust correlations between patient size (Deff and Dw) and the patient's age, with R2 values ranging from 0.65 to 0.86. Notably, larger Dw values were consistently observed compared to Deff. For male patients, Deff measurements ranged from 9.02 to 18.77 cm, with Dw values spanning 9.83 to 20.16 cm. Female patients exhibited Deff values ranging from 8.77 to 17.41 cm and Dw values ranging from 8.92 to 18.37 cm. These findings shed light on the crucial relationship between age and patient size, facilitating more precise dose calculations.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 4 条
  • [1] Advancing pediatric head CT dose prediction: correlating patient size metrics with AP and LAT dimensions in Moroccan population
    Sekkat, H.
    Elmansouri, K.
    Khallouqi, A.
    Halimi, A.
    El Rhazouani, O.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024, 179 (9-10): : 1295 - 1307
  • [2] Age-Dependent Changes in Effective Dose in Pediatric Brain CT: Comparisons of Estimation Methods
    Inoue, Yusuke
    Mori, Masahiro
    Itoh, Hiroyasu
    Mitsui, Kohei
    Miyatake, Hiroki
    Yamane, Takuro
    Hata, Hirofumi
    TOMOGRAPHY, 2024, 10 (01) : 14 - 24
  • [3] A new approach to dose reference levels in pediatric CT: Age and size-specific dose estimation
    Rawashdeh, Mohammad
    Saade, Charbel
    Mousa, Dana S. Al
    Abdelrahman, Mostafa
    Kumar, Praveen
    McEntee, Mark
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [4] Conversion factor for size specific dose estimation of head CT scans based on age, for individuals from 0 up to 18 years old
    da Silva, Edilaine Honorio
    Baffa, Oswaldo
    Elias Jr, Jorge
    Buls, Nico
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (08)