The Cost-Optimal Control of Building Air Conditioner Loads Based on Machine Learning: A Case Study of an Office Building in Nanjing

被引:0
|
作者
Guo, Zhenwei [1 ,2 ]
Wang, Xinyu [2 ]
Wang, Yao [3 ,4 ]
Zhu, Fenglei [4 ]
Zhou, Haizhu [5 ]
Zhang, Miao [5 ]
Wang, Yuxiang [2 ]
机构
[1] State Key Lab Bldg Safety & Built Environm, Beijing 100013, Peoples R China
[2] Chinese Soc Urban Studies, Beijing, Peoples R China
[3] Tsinghua Univ, Sch Architecture, Beijing 100190, Peoples R China
[4] Beijing Glory PKPM Technol Co Ltd, Beijing 100013, Peoples R China
[5] China Acad Bldg Res, Beijing 100013, Peoples R China
关键词
building air conditioner load; machine learning; load control; energy costs; indoor temperature; ENERGY-CONSUMPTION; FAULT-DIAGNOSIS; DEMAND RESPONSE; RESERVE MARKET; COOLING SYSTEM; HVAC SYSTEM; PREDICTION; MODEL;
D O I
10.3390/buildings14103040
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building envelopes and indoor environments exhibit thermal inertia, forming a virtual energy storage system in conjunction with the building air conditioner (AC) system. This system represents a current demand response resource for building electricity use. Thus, this study centers on the CatBoost algorithm within machine learning (ML) technology, utilizing the LASSO regression model for feature selection and applying the Optuna framework for hyperparameter optimization (HPO) to develop a cost-optimal control method for minimizing building AC loads. This method addresses the challenges associated with traditional load forecasting and control methods, which are often impacted by environmental temperature, building parameters, and user behavior uncertainties. These methods struggle to accurately capture the complex dynamics and nonlinear relationships of AC operations, making it difficult to devise AC operation and virtual energy storage scheduling strategies effectively. The proposed method was applied and validated using a case study of an office building in Nanjing, China. The prediction results showed coefficient of variation in root mean square error (CV-RMSE) values of 6.4% and 2.2%. Compared with the original operating conditions, the indoor temperature remained within a comfortable range, the AC load was reduced by 5.25%, and the operating energy costs were reduced by 24.94%. These results demonstrate that the proposed method offers improved computational efficiency, enhanced model performance, and economic benefits.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Dynamic reliability analysis of Aerial Building Machine under extreme wind loads using improved QBDC-based active learning
    Wang, Jiaqi
    Zhang, Limao
    Yang, Hui
    Liu, Huabei
    Skibniewski, Miroslaw J.
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2024, 244
  • [42] Comparing hyperparameter tuning methods in machine learning based urban building energy modeling: A study in Chicago
    Quan, Steven Jige
    ENERGY AND BUILDINGS, 2024, 317
  • [43] Robust stochastic optimal operation of an industrial building including plug in electric vehicle, solar-powered compressed air energy storage and ice storage conditioner: A case study in the city of Kaveh, Iran
    Doosti, Reza
    Sedighizadeh, Mostafa
    Sedighizadeh, Davoud
    Fini, Alireza Sheikhi
    IET SMART CITIES, 2022, 4 (01) : 56 - 77
  • [44] An IoT-Based Thermoelectric Air Management Framework for Smart Building Applications: A Case Study for Tropical Climate
    Irshad, Kashif
    Almalawi, Abdulmohsen
    Khan, Asif Irshad
    Alam, Mottahir
    Zahir, Md Hasan
    Ali, Amjad
    SUSTAINABILITY, 2020, 12 (04)
  • [45] Research on Semi-active Air Suspensions of Heavy Trucks Based on a Combination of Machine Learning and Optimal Fuzzy Control
    Yuan, Huan
    Nguyen, Vanliem
    Zhou, Huaxiang
    SAE INTERNATIONAL JOURNAL OF VEHICLE DYNAMICS STABILITY AND NVH, 2021, 5 (02): : 159 - 172
  • [46] Leveraging multi-zone building data with machine learning-based models and genetic algorithms to optimize air handling units
    Nisa, Elsa Chaerun
    Kuan, Yean-Der
    Lin, Cheng-Hsiang
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [47] Direct load control-based optimal scheduling strategy for demand response of air-conditioning systems in rural building complex
    Wei, Ying 'an
    Meng, Qinglong
    Zhao, Fan
    Yu, Lingli
    Zhang, Liang
    Jiang, Le
    BUILDING AND ENVIRONMENT, 2024, 258
  • [48] Machine learning approach to extract building footprint from high-resolution images: the case study of Makkah, Saudi Arabia
    Faisal, Kamil
    Imam, Ayman
    Majrashi, Abdulrahman
    Hegazy, Ibrahim
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (02) : 655 - 663
  • [49] Analysis and Selection of Optimal Perovskite/Silicon Tandem Configuration for Building Integrated Photovoltaics Based on Their Annual Outdoor Energy Yield Predicted by Machine Learning
    Nguyen, Dong C.
    Asada, Tomoki
    Raifuku, Itaru
    Ishikawa, Yasuaki
    SOLAR RRL, 2024, 8 (09)
  • [50] Experimental study on control strategies of radiant floor cooling system with direct-ground cooling source and displacement ventilation system: A case study in an office building
    Ren, Jing
    Liu, Jiying
    Zhou, Shiyu
    Kim, Moon Keun
    Song, Shoujie
    ENERGY, 2022, 239