Improving the thermal-hydraulic performance of air-cooled battery thermal management system by flow splitters

被引:2
|
作者
Gao, Chen [1 ]
Song, Kewei [1 ,2 ]
He, Rong [1 ]
Qi, Yue [1 ]
Gu, Bingdong [2 ]
Su, Mei [1 ]
An, Zhoujian [3 ]
机构
[1] Lanzhou Jiaotong Univ, Sch Mech Engn, Lanzhou 730070, Peoples R China
[2] Qinghai Minzu Univ, Sch Civil & Transportat Engn, Xining 810007, Peoples R China
[3] Lanzhou Univ Technol, Coll Energy & Power Engn, Lanzhou 730050, Peoples R China
基金
中国国家自然科学基金;
关键词
Air-cooled; Battery; Thermal management; Flow splitter; Performance;
D O I
10.1016/j.est.2024.113818
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The simplicity and cost-effectiveness of air-cooled battery thermal management system (BTMS) has made them increasingly popular. However, the heat of battery cannot be fully absorbed by the air at high discharge rates, which is a disadvantage that cannot be ignored. Moreover, the downstream battery's temperature cannot be lowered as it is affected by the upstream air with high-temperature. To address these disadvantages, an innovative air-cooled BTMS with flow splitters arranged at the rear of the batteries is proposed to improve the thermal-hydraulic performance of BTMS. The inclined flow splitter effectively decreases the wake zone behind the battery, and the pressure drop is significantly reduced by up to 11.9 % compared with the original model without flow splitter. Besides, the maximum temperature is reduced and the temperature uniformity is improved by the inclined flow splitter due to the heat conduction by the flow splitter and the decrease of wake zone size. The maximum temperature of the battery with inclined flow splitter decreases by 2.14 degrees C, and the temperature difference decreases by up to 49.2 % under the same pumping power compared with the original model without flow splitter. The arrangement of inclined flow splitter significantly enhanced the thermal-hydraulic performance of the air-cooled thermal management system, which served as a valuable reference for the future design of aircooled BTMS.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Numerical study on air-cooled battery thermal management system considering the sheer altitude effect
    Li, Yonghao
    Kong, Benben
    Qiu, Chenghui
    Li, Yu
    Jiang, Yanlong
    APPLIED THERMAL ENGINEERING, 2025, 258
  • [32] Multiobjective optimization of air-cooled battery thermal management system based on heat dissipation model
    Chen, Jiahui
    Zhao, Xiaobo
    Wang, Biao
    Zhang, Chenghao
    Xuan, Dongji
    IONICS, 2021, 27 (03) : 1307 - 1322
  • [33] Configuration optimization of battery pack in parallel air-cooled battery thermal management system using an optimization strategy
    Chen, Kai
    Wang, Shuangfeng
    Song, Mengxuan
    Chen, Lin
    APPLIED THERMAL ENGINEERING, 2017, 123 : 177 - 186
  • [34] Design of the structure of battery pack in parallel air-cooled battery thermal management system for cooling efficiency improvement
    Chen, Kai
    Song, Mengxuan
    Wei, Wei
    Wang, Shuangfeng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 132 : 309 - 321
  • [35] Computational study on thermal management for an air-cooled lithium-ion battery
    Morali, Ugur
    ENERGY STORAGE, 2024, 6 (01)
  • [36] Thermal analysis of modified Z-shaped air-cooled battery thermal management system for electric vehicles br
    Shen, Xueyang
    Cai, Tianao
    He, Chunmin
    Yang, Yi
    Chen, Miao
    JOURNAL OF ENERGY STORAGE, 2023, 58
  • [37] Thermal analysis of modified Z-shaped air-cooled battery thermal management system for electric vehicles br
    Shen, Xueyang
    Cai, Tianao
    He, Chunmin
    Yang, Yi
    Chen, Miao
    JOURNAL OF ENERGY STORAGE, 2023, 58
  • [38] Design optimization and cooling performance assessment of a pulsating Air-Cooled Lithium-Ion battery thermal management System
    Sofi, Amir Yousf
    Qayoum, Adnan
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59
  • [39] Structure optimization of parallel air-cooled battery thermal management system with U-type flow for cooling efficiency improvement
    Chen, Kai
    Song, Mengxuan
    Wei, Wei
    Wang, Shuangfeng
    ENERGY, 2018, 145 : 603 - 613
  • [40] Numerical investigation of cooling performance of a novel air-cooled thermal management system for cylindrical Li-ion battery module
    Kausthubharam
    Koorata, Poornesh K.
    Chandrasekaran, Neelakandan
    APPLIED THERMAL ENGINEERING, 2021, 193