A Clinically Feasible Electrode Array for 3D Intraoperative Electrical Impedance Tomography-Based Surgical Margin Assessment in Robot-Assisted Radical Prostatectomy

被引:3
|
作者
Kossmann, Shannon E. [1 ]
Murphy, Ethan K. [1 ]
Doussan, Allaire F. [1 ]
Lloyd, Sophie [1 ]
Halter, Ryan J. [1 ,2 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Dartmouth Coll, Geisel Sch Med, Hanover, NH 03755 USA
基金
美国国家卫生研究院;
关键词
Electrodes; Voltage measurement; Electrical impedance tomography; Arrays; Impedance; Conductivity; Biomedical measurement; Electrical impedance tomography (EIT); prostate cancer; surgical margin assessment; BREAST; SPECTROSCOPY; SYSTEM; EIT;
D O I
10.1109/TBME.2024.3408720
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: A novel small form factor circular electrode array was designed specifically for electrical impedance tomography (EIT) based assessment of surgical margins during robot assisted radical prostatectomy (RARP). Methods: The electrode array consists of 33 gold-plated electrodes arranged within a 9.5 mm diameter circular footprint on the end of a surgical probe that can be introduced through a standard 12 mm laparoscopic port used during RARP. The electrode array contains 8 larger, low-contact impedance outer electrodes dedicated for current drive and an internal grid of 25 smaller electrodes for simultaneous voltage measurement. Separating electrode geometry by function is designed to improve current delivery, speed, and resolution while reducing hardware requirements. Results: Simulations demonstrated that 1 mm diameter hemispherical prostate cancer inclusions could be localized within regions of adipose and benign prostate tissue; 1.5 mm diameter inclusions were required for localization within muscle tissue. A 2.38 mm diameter aluminum rod in 0.2 S/m saline could be localized throughout the imaging domain with a position error of less than 2.5 mm for depths from the electrode array surface of up to 1.7 mm. Ex vivo tissue experiments with a bovine model demonstrate visual congruence of muscle and adipose tissue locations between the sample and reconstructed images. Conclusion: Simulation and experimental results indicate good detection and location of inclusions. Significance: These results suggest the proposed electrode array design can provide sufficient accuracy in the detection and localization of prostate cancer against clinically relevant background tissues for use during RARP.
引用
收藏
页码:3134 / 3145
页数:12
相关论文
共 32 条
  • [1] 3D Microendoscopic Electrical Impedance Tomography for Margin Assessment During Robot-Assisted Laparoscopic Prostatectomy
    Mahara, Aditya
    Khan, Shadab
    Murphy, Ethan K.
    Schned, Alan R.
    Hyams, Elias S.
    Halter, Ryan J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (07) : 1590 - 1601
  • [2] The impact of 3D models on positive surgical margins after robot-assisted radical prostatectomy
    Checcucci, Enrico
    Pecoraro, Angela
    Amparore, Daniele
    De Cillis, Sabrina
    Granato, Stefano
    Volpi, Gabriele
    Sica, Michele
    Verri, Paolo
    Piana, Alberto
    Piazzolla, Pietro
    Manfredi, Matteo
    Vezzetti, Enrico
    Di Dio, Michele
    Fiori, Cristian
    Porpiglia, Francesco
    Urology, Uro-technology And Some Working Group Of The Young Academic Urologists Working Party Of The European Association Of
    WORLD JOURNAL OF UROLOGY, 2022, 40 (09) : 2221 - 2229
  • [3] The impact of 3D models on positive surgical margins after robot-assisted radical prostatectomy
    Enrico Checcucci
    Angela Pecoraro
    Daniele Amparore
    Sabrina De Cillis
    Stefano Granato
    Gabriele Volpi
    Michele Sica
    Paolo Verri
    Alberto Piana
    Pietro Piazzolla
    Matteo Manfredi
    Enrico Vezzetti
    Michele Di Dio
    Cristian Fiori
    Francesco Porpiglia
    World Journal of Urology, 2022, 40 : 2221 - 2229
  • [4] ROBOT-ASSISTED RADICAL PROSTATECTOMY WITH 3D-BASED AUGMENTED REALITY
    Porpiglia, Francesco
    Bertolo, Riccardo
    Checcucci, Enrico
    Amparore, Daniele
    Fiori, Cristian
    JOURNAL OF UROLOGY, 2018, 199 (04): : E820 - E820
  • [5] THE ROLE OF PROSTATE MRI 3D-RECONSTRUCTION ROBOT-ASSISTED RADICAL PROSTATECTOMY IN REDUCING POSITIVE SURGICAL MARGIN RATE
    Porpiglia, Francesco
    Manfredi, Matteo
    Checcucci, Enrico
    Mele, Fabrizio
    Bertolo, Riccardo
    De Luca, Stefano
    Garrou, Diletta
    Cattaneo, Giovanni
    Amparore, Daniele
    Bollito, Enrico
    Fiori, Cristian
    ANTICANCER RESEARCH, 2017, 37 (04) : 2097 - 2097
  • [6] Electrical impedance map (EIM) for margin assessment during robot-assisted laparoscopic prostatectomy (RALP) using a microendoscopic probe
    Mahara, Aditya
    Khan, Shadab
    Schned, Alan R.
    Hyams, Elias S.
    Halter, Ryan J.
    MEDICAL IMAGING 2015: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2015, 9415
  • [7] NOVEL SURGICAL TILE-PRO NAVIGATION WITH 3D PROSTATE CANCER MODEL DURING ROBOT-ASSISTED RADICAL PROSTATECTOMY
    Abreu, Andre Luis de Castro
    Nakamoto, Masahiko
    Shoji, Sunao
    Leslie, Scott
    Berger, Andre
    Goh, Alvin
    Desai, Mihir
    Aron, Monish
    Gill, Inderbir
    Ukimura, Osamu
    JOURNAL OF UROLOGY, 2013, 189 (04): : E519 - E520
  • [8] Objective surgical skill assessment based on automatic recognition of dissection and exposure times in robot-assisted radical prostatectomy
    Sato, Kodai
    Takenaka, Shin
    Kitaguchi, Daichi
    Zhao, Xue
    Yamada, Atsushi
    Ishikawa, Yuto
    Takeshita, Nobushige
    Takeshita, Nobuyoshi
    Sakamoto, Shinichi
    Ichikawa, Tomohiko
    Ito, Masaaki
    LANGENBECKS ARCHIVES OF SURGERY, 2025, 410 (01)
  • [9] Positive Surgical Margin Trends in Patients with Pathologic T3 Prostate Cancer Treated with Robot-Assisted Radical Prostatectomy
    Lightfoot, Andrew J.
    Su, Yu-Kai
    Sehgal, Shailen S.
    Lee, Ziho
    Greaves, Giovanni H.
    Yu, Sue-Jean S.
    Llukani, Elton
    Su, Yu-Chen
    Lee, David I.
    JOURNAL OF ENDOUROLOGY, 2015, 29 (06) : 634 - 639
  • [10] 3D electrical impedance tomography represented by reconstructed planes in a semispherical electrode array model
    He, Wei
    Ran, Peng
    Xu, Zheng
    Li, Bing
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2013, 41 (04) : 433 - 446