Efficient ECG classification based on Chi-square distance for arrhythmia detection

被引:3
|
作者
Al-Shammary D. [1 ]
Noaman Kadhim M. [1 ]
Mahdi A.M. [1 ]
Ibaida A. [2 ]
Ahmed K. [2 ]
机构
[1] College of Computer Science and Information Technology, University of Al-Qadisiyah, Al Diwaniyah
[2] Intelligent Technology Innovation Lab, Victoria University, Melbourne
关键词
Arrhythmia classification; Chi-square distance; Electrocardiogram (ECG) signal; Particle swarm optimization (PSO);
D O I
10.1016/j.jnlest.2024.100249
中图分类号
学科分类号
摘要
This study introduces a new classifier tailored to address the limitations inherent in conventional classifiers such as K-nearest neighbor (KNN), random forest (RF), decision tree (DT), and support vector machine (SVM) for arrhythmia detection. The proposed classifier leverages the Chi-square distance as a primary metric, providing a specialized and original approach for precise arrhythmia detection. To optimize feature selection and refine the classifier's performance, particle swarm optimization (PSO) is integrated with the Chi-square distance as a fitness function. This synergistic integration enhances the classifier's capabilities, resulting in a substantial improvement in accuracy for arrhythmia detection. Experimental results demonstrate the efficacy of the proposed method, achieving a noteworthy accuracy rate of 98% with PSO, higher than 89% achieved without any previous optimization. The classifier outperforms machine learning (ML) and deep learning (DL) techniques, underscoring its reliability and superiority in the realm of arrhythmia classification. The promising results render it an effective method to support both academic and medical communities, offering an advanced and precise solution for arrhythmia detection in electrocardiogram (ECG) data. © 2024 The Authors
引用
收藏
相关论文
共 44 条
  • [1] A Fuzzy KNN Algorithm Based on Weighted Chi-square Distance
    Wang, Xingang
    Yao, Peipei
    PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND APPLICATION ENGINEERING (CSAE2018), 2018,
  • [2] Robustness of Chi-square and Canberra distance metrics for computer intrusion detection
    Emran, SM
    Ye, N
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2002, 18 (01) : 19 - 28
  • [3] Network Selection Algorithm Based on Chi-Square Distance in Heterogeneous Wireless Networks
    Hewei Yu
    Lihua Chen
    Jingxi Yu
    Wireless Personal Communications, 2020, 111 : 1625 - 1643
  • [4] Network Selection Algorithm Based on Chi-Square Distance in Heterogeneous Wireless Networks
    Yu, Hewei
    Chen, Lihua
    Yu, Jingxi
    WIRELESS PERSONAL COMMUNICATIONS, 2020, 111 (03) : 1625 - 1643
  • [5] A Heterogeneous Wireless Network Selection Algorithm for Smart Distribution Grid Based on Chi-square Distance
    Chou, Haoran
    2018 10TH INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS (ICCCAS 2018), 2018, : 325 - 330
  • [6] Improved Wknn Indoor Positioning Algorithm Based On C-Means And Chi-Square Distance
    Hu, Shihui
    Shen, Chong
    Zhang, Kun
    Huang, Xing
    2019 INTERNATIONAL CONFERENCE ON ROBOTS & INTELLIGENT SYSTEM (ICRIS 2019), 2019, : 432 - 435
  • [7] A New fault Line Selection Method For Resonant Grounded Distribution Network Based on Chi-square Distance
    Cheng, Chang
    Shao, Wenquan
    Zhang, Ying
    Goan, Xin
    2021 8TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2021, : 345 - 348
  • [8] Identification of Transcription Factor Binding Sites Based on the Chi-Square (χ2) distance of a Probabilistic Vector Model
    Huang, Lun
    Al Bataineh, Mohammad
    Atkin, G. E.
    Mohammed, Ismaeel
    Zhang, Wei
    Parra, Maria
    del Mar Perez, Maria
    2009 INTERNATIONAL CONFERENCE ON FUTURE BIOMEDICAL INFORMATION ENGINEERING (FBIE 2009), 2009, : 73 - +
  • [9] Mammogram Classification Using Chi-Square Distribution on Local Binary Pattern Features
    Gardezi, Syed Jamal Safdar
    Faye, Ibrahima
    Adjed, Faouzi
    Kamel, Nidal
    Hussain, Muhammad
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (01) : 30 - 34
  • [10] Scalable chi-square distance versus conventional statistical distance for process monitoring with uncorrelated data variables
    Ye, N
    Borror, CM
    Parmar, D
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2003, 19 (06) : 505 - 515