Towards high throughput analysis using 96-well plate solid phase extraction to determine sedatives and R-blocker residues in food control monitoring

被引:2
|
作者
Arrizabalaga-Larranaga, Ane [1 ]
van Doorn, Dieke [1 ]
Sterk, Saskia S. [1 ]
机构
[1] Wageningen Univ & Res, Dept Growth Promotors, European Union Reference Lab, Wageningen Food Safety Res WFSR, NL-6708WB Wageningen, Netherlands
关键词
Single matrix fortified calibration curve; Sample preparation; LC-MS/MS; Food safety; Animal tissues; Sedatives; LIQUID-CHROMATOGRAPHY; BETA-BLOCKER; ANIMAL-TISSUES; BOVINE KIDNEY; PIG-TISSUES; TRANQUILIZERS; VALIDATION; CARAZOLOL; AZAPERONE; PORCINE;
D O I
10.1016/j.aca.2024.343335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Veterinary drugs are widely used in animal production to prevent infections and treat diseases but, this may cause a risk to consumers. Due to the high number of food samples required to monitor yearly, simple, fast, sensitive and selective analytical methods are needed in control laboratories to ensure consumers safety. Nevertheless, many analytical methodologies available in these laboratories include multiple steps and therefore are time-consuming and hinder the analysis throughput requiring significant amounts of solvents and reagents. Results: This work developed a 96-well plate solid phase extraction (SPE) method for the extraction of seven sedatives and a beta-blocker in animal kidney by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The developed method was validated based on Implementing Regulation (EU) 2021/808 in kidney, meat and fish. The performance characteristics of the validation (1-5 mu g kg(-1)) showed good linearity (R-2 > 0.998) while decision limits (CC alpha) were between 1 and 1.2 mu g kg(-1). Trueness and precision were determined at three levels (n = 7) and the results showed values ranging from 85 to 103 % and from 1 to 9 %, respectively. The feasibility of the method was demonstrated for the residue control requirement established by EU. Method was applied to 201 samples of kidney, meat and fish. Significance: This study is the first to present an optimized and validated holistic method for sedatives and beta-blocker using 96-well plate SPE and UHPLC-MS/MS. The method showed good performance in kidney, meat and fish samples being an universal method for any species along the same type of sample. The fast, easy, efficient, reliable and universal method showed high throughput and so reduced the analysis time by nine-fold and the required solvent amount by four times fulfilling the green chemistry principals.
引用
收藏
页数:9
相关论文
共 33 条
  • [1] A high-throughput approach for the determination of pesticide residues in cucumber samples using solid-phase microextraction on 96-well plate
    Bagheri, Habib
    Es'haghi, Ali
    Es-haghi, Ali
    Mesbahi, Noushin
    ANALYTICA CHIMICA ACTA, 2012, 740 : 36 - 42
  • [2] High Throughput Liquid Chromatography/Mass Spectrometry Bioanalysis Using 96-Well Disk Solid Phase Extraction Plate for the Sample Preparation
    Simpson, H.
    Berthemy, A.
    Buhrman, D.
    Burton, R.
    Rapid Communications in Mass Spectrometry, 12 (02):
  • [3] High throughput liquid chromatography mass spectrometry bioanalysis using 96-well disk solid phase extraction plate for the sample preparation
    Simpson, H
    Berthemy, A
    Buhrman, D
    Burton, R
    Newton, J
    Kealy, M
    Wells, D
    Wu, DL
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (02) : 75 - 82
  • [4] Automated solid-phase extraction of atenolol from human urine for high throughput LC-MS-MS analysis using a strata™-X 96-well plate
    Huq, Shahana Wahab
    Kallury, Krishna
    LC GC NORTH AMERICA, 2007, : 62 - 62
  • [5] High-throughput micro-solid phase extraction on 96-well plate using dodecyl methacrylate-ethylen glycol dimethacrylate monolithic copolymer
    Bagheri, Habib
    Es'haghi, Ali
    Es-haghi, Ali
    Mohammadkhani, Elham
    ANALYTICA CHIMICA ACTA, 2013, 792 : 59 - 65
  • [6] High-throughput 96-well solid-phase extraction for preparation of tetracycline followed by liquid chromatography and mass spectrometry analysis
    Chen, Kang
    Wang, Jie
    Li, Shiyan
    Wang, Yang
    Zhang, Yiqi
    Shen, Qing
    ELECTROPHORESIS, 2019, 40 (04) : 555 - 562
  • [7] A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction
    Stubleski, Jordan
    Kukucka, Petr
    Salihovic, Samira
    Lind, P. Monica
    Lind, Lars
    Karrman, Anna
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1546 : 18 - 27
  • [8] HIGH THROUGHPUT LC-MS/MSMETHOD FOR THE QUANTITATION OF LINAGLIPTIN IN HUMAN PLASMA BY SOLID PHASE EXTRACTION USING 96 WELL PLATE FORMAT
    Rao, Tangudu Nagabhusana
    Sankar, Guntuku Girija
    Rani, Lade Jyothi
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2016, 7 (03): : 1321 - 1330
  • [9] A new approach to the application of solid phase extraction disks with LC-MS/MS for the analysis of drugs on a 96-well plate format
    Cudjoe, Erasmus
    Pawliszyn, Janusz
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (04) : 556 - 562
  • [10] Rapid and high-throughput analysis of N-glycans from ovarian cancer serum using a 96-well plate platform
    Kim, Yun-Gon
    Jeong, Hee-Jin
    Jang, Kyoung-Soon
    Yang, Yung-Hun
    Song, Yong-Sang
    Chung, Junho
    Kim, Byung-Gee
    ANALYTICAL BIOCHEMISTRY, 2009, 391 (02) : 151 - 153