Inverse Design of RF Coil for Slim Nuclear Magnetic Resonance Logging Tool

被引:0
|
作者
Long, Zhihao [1 ]
Xiao, Lizhi [1 ,2 ]
Luo, Sihui [1 ]
Liu, Huabing [3 ]
Zhao, Xiaoguang [4 ]
机构
[1] China Univ Petr, State Key Lab Petr Resources & Engn, Beijing 102249, Peoples R China
[2] Harvard SEAS CUPB Joint Lab Petr Sci, Cambridge, MA 02138 USA
[3] Beijing Limecho Technol Corp Ltd, Beijing 102299, Peoples R China
[4] Tsinghua Univ, Dept Precis Instrument, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; Magnetostatics; Nuclear magnetic resonance; Magnetic field measurement; Saturation magnetization; Probes; Coils; Radio frequency; Permanent magnets; Signal to noise ratio; Coil inversion design; low-field nuclear magnetic resonance (NMR); signal-to-noise ratio (SNR); target-field method; INSIDE-OUT NMR; TARGET-FIELD METHOD; REGION;
D O I
10.1109/TIM.2024.3470979
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nuclear magnetic resonance (NMR) logging provides key parameters for reservoir evaluation and production operations. In the design of an NMR logging tool, the combination of inhomogeneous static magnetic and radio frequency (RF) fields results in a complex signal distribution. Matching the two magnetic fields allows one to accurately calculate the sensitive volume of the probe and estimate the signal amplitude. The structure of the RF coil is typically optimized to match the static field via a time-consuming procedure. In this study, a magnetic-charge model is used to calculate the static magnetic field of a simplified square-shaped magnet. Subsequently, the target-field method is used to design the RF coil for matching the specific static magnet field generated by the magnet. The designed coil provides a more homogeneous NMR signal in the azimuthal orientation. A cylindrical slice with a height of 100 and 32 mm from the axis of symmetry constitutes the sensitive volume of the probe. To assess the detection effectiveness of the probe, 1-D and 2-D NMR experiments are conducted using copper-sulfate solutions and white-oil samples with different viscosities. The high-gradient magnetic field (i.e., 3.2 T/m) of the probe is used to facilitate diffusion coefficient measurements for high-viscosity fluids.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] SMOOTH SADDLE RF COIL FOR MAGNETIC-RESONANCE-IMAGING
    VASLOW, DF
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 1991, 4 (11) : 501 - 506
  • [32] TOC estimation of shale oil reservoir by combining nuclear magnetic resonance logging and nuclear physics logging
    Feng, Ziyan
    Feng, Cheng
    Zhong, Yuntao
    Qin, Zhijun
    Mao, Rui
    Zhao, Lei
    Zong, Xianghua
    JOURNAL OF GEOPHYSICS AND ENGINEERING, 2022, 19 (04) : 833 - 845
  • [33] Design and testing of high sensitivity microreceiver coil apparatus for nuclear magnetic resonance and imaging
    Seeber, DA
    Cooper, RL
    Ciobanu, L
    Pennington, CH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (04): : 2171 - 2179
  • [34] THE INVERSE PROBLEM FOR NUCLEAR-MAGNETIC-RESONANCE
    DANIELL, GJ
    HORE, PJ
    MAXIMUM ENTROPY AND BAYESIAN METHODS /, 1989, 36 : 297 - 302
  • [35] An inverse method to design RF coil arrays optimized for SENSE imaging
    Muftuler, L. Tugan
    Chen, Gang
    Nalcioglu, Orhan
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (24): : 6457 - 6469
  • [36] Review of Nuclear Magnetic Resonance magnet for oil well logging
    Zhang, YM
    Xia, PC
    Yu, YJ
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 763 - 766
  • [37] Design and Analysis of Microstrip-Based RF Birdcage Coil for 1.5 T Magnetic Resonance Imaging
    Thiyagarajan, Krishnan
    Kesavamurthy, Thangavelu
    Bharathkumar, Gattu
    APPLIED MAGNETIC RESONANCE, 2014, 45 (03) : 255 - 268
  • [38] Nuclear magnetic resonance imaging for viscosity measurements of non-Newtonian fluids using a miniaturized RF coil
    Goloshevsky, AG
    Walton, JH
    Shutov, MV
    de Ropp, JS
    Collins, SD
    McCarthy, MJ
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (02) : 513 - 518
  • [39] Design of a Rectangular Loop-Shape RF Coil for 7-Tesla Magnetic Resonance Imaging
    Salama, Sanaa
    2017 IEEE ASIA PACIFIC MICROWAVE CONFERENCE (APMC), 2017, : 1044 - 1047
  • [40] Design and Analysis of Microstrip-Based RF Birdcage Coil for 1.5 T Magnetic Resonance Imaging
    Krishnan Thiyagarajan
    Thangavelu Kesavamurthy
    Gattu Bharathkumar
    Applied Magnetic Resonance, 2014, 45 : 255 - 268