Inverse Design of RF Coil for Slim Nuclear Magnetic Resonance Logging Tool

被引:0
|
作者
Long, Zhihao [1 ]
Xiao, Lizhi [1 ,2 ]
Luo, Sihui [1 ]
Liu, Huabing [3 ]
Zhao, Xiaoguang [4 ]
机构
[1] China Univ Petr, State Key Lab Petr Resources & Engn, Beijing 102249, Peoples R China
[2] Harvard SEAS CUPB Joint Lab Petr Sci, Cambridge, MA 02138 USA
[3] Beijing Limecho Technol Corp Ltd, Beijing 102299, Peoples R China
[4] Tsinghua Univ, Dept Precis Instrument, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance imaging; Magnetostatics; Nuclear magnetic resonance; Magnetic field measurement; Saturation magnetization; Probes; Coils; Radio frequency; Permanent magnets; Signal to noise ratio; Coil inversion design; low-field nuclear magnetic resonance (NMR); signal-to-noise ratio (SNR); target-field method; INSIDE-OUT NMR; TARGET-FIELD METHOD; REGION;
D O I
10.1109/TIM.2024.3470979
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nuclear magnetic resonance (NMR) logging provides key parameters for reservoir evaluation and production operations. In the design of an NMR logging tool, the combination of inhomogeneous static magnetic and radio frequency (RF) fields results in a complex signal distribution. Matching the two magnetic fields allows one to accurately calculate the sensitive volume of the probe and estimate the signal amplitude. The structure of the RF coil is typically optimized to match the static field via a time-consuming procedure. In this study, a magnetic-charge model is used to calculate the static magnetic field of a simplified square-shaped magnet. Subsequently, the target-field method is used to design the RF coil for matching the specific static magnet field generated by the magnet. The designed coil provides a more homogeneous NMR signal in the azimuthal orientation. A cylindrical slice with a height of 100 and 32 mm from the axis of symmetry constitutes the sensitive volume of the probe. To assess the detection effectiveness of the probe, 1-D and 2-D NMR experiments are conducted using copper-sulfate solutions and white-oil samples with different viscosities. The high-gradient magnetic field (i.e., 3.2 T/m) of the probe is used to facilitate diffusion coefficient measurements for high-viscosity fluids.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Design Scheme of Proximal Adaptive Noise Cancellation in Shallow Hydrological Monitoring Using a Multichannel Nuclear Magnetic Resonance Logging Tool
    Lin, Tingting
    Wang, Hualiang
    Yu, Qi
    Zhu, Jinbao
    Fan, Tiehu
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [22] RF Head Coil Design With Improved RF Magnetic Near-Fields Uniformity for Magnetic Resonance Imaging (MRI) Systems
    Sohn, Sung-Min
    DelaBarre, Lance
    Gopinath, Anand
    Vaughan, John Thomas
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2014, 62 (08) : 1784 - 1789
  • [23] Planar Coil Design for Nuclear Magnetic Resonance Gyroscope Using Genetic Algorithm
    Shao, Yanmeng
    Tang, Feng
    Zhao, Nan
    IEEE SENSORS JOURNAL, 2025, 25 (05) : 8196 - 8205
  • [24] An inverse design of an open, head/neck RF coil for MRI
    Lawrence, BG
    Crozier, S
    Cowin, G
    Yau, DD
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (09) : 1024 - 1030
  • [25] EFFECT OF CONDUCTION CURRENTS IN MAGNETIC LOGGING WITH A 2-COIL TOOL
    KAUFMAN, AA
    SOCHELNI.VV
    GEOPHYSICS, 1970, 35 (06) : 1176 - &
  • [26] Quantifying motional dynamics in nuclear magnetic resonance logging
    O'Neill, Keelan T.
    Hopper, Timothy A. J.
    Fridjonsson, Einar O.
    Johns, Michael L.
    JOURNAL OF MAGNETIC RESONANCE, 2022, 337
  • [27] Pulsed power source in Nuclear Magnetic Resonance Logging
    Chen, Jingjing
    Li, Zhihua
    Kong, Li
    Zhang, Pu
    Geophysical Solutions for Environment and Engineering, Vol 1 and 2, 2006, : 1138 - 1142
  • [28] Experiment analysis and application on nuclear magnetic resonance logging
    Ma, Huolin
    Pan, Heping
    Zhang, Zeyu
    NEAR-SURFACE GEOPHYSICS AND GEOHAZARDS - PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL AND ENGINEERING GEOPHYSICS, VOLS 1 AND 2, 2010, : 974 - 978
  • [29] AN INVERSE DESIGN OF MAGNETIC FOCUSING COIL FOR ELECTROSTATIC AND MAGNETIC IMAGING
    ZHOU, L
    QIU, BC
    NI, GQ
    OPTIK, 1988, 78 (02): : 54 - 58
  • [30] U-MODE BALANCING METHOD FOR CROSSED-COIL NUCLEAR MAGNETIC RESONANCE RF HEAD
    BLUME, RJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1962, 33 (12): : 1472 - &