On the thermal performance of a shell and double coil heat exchanger: Numerical analysis of the geometrical characteristics impacts

被引:3
作者
Karouei, Seyed Hossein Hashemi [1 ]
Jasim, Dheyaa J. [2 ]
Basem, Ali [3 ]
Sultan, Abbas J. [4 ]
Al-Rubaye, Ameer H. [5 ]
Ajarostaghi, Seyed Soheil Mousavi [6 ]
机构
[1] Babol Noshirvani Univ Technol BNUT, Fac Mech Engn, Babol 4714871167, Iran
[2] Al Amarah Univ Coll, Dept Petr Engn, Maysan, Iraq
[3] Warith Al Anbiyaa Univ, Fac Engn, Karbala 56001, Iraq
[4] Univ Technol Baghdad, Dept Chem Engn, Baghdad, Iraq
[5] Al Kitab Univ, Dept Petr Engn, Altun Kupri, Iraq
[6] Babol Noshirvani Univ Technol, Fac Mech Engn, Babol 4714871167, Iran
关键词
Heat exchanger; Shell-and-Coil; Thermal analysis; Hybrid nanofluid; Numerical method; CFD; FLOW;
D O I
10.1016/j.csite.2024.105349
中图分类号
O414.1 [热力学];
学科分类号
摘要
Using a double coil instead of a simple coil in a shell-and-coil heat exchanger results in more extraordinary heat transmission because of more space occupation. This work involves the numerical evaluation of heat transfer and fluid flow in a shell and double coil heat exchanger, utilizing a commercial CFD code based on the finite volume approach. The employed heat transfer fluids are pure water and Water/MgO-TiO2 hybrid nanofluid. The volume concentration of utilized hybrid nanofluid is phi 1 = phi 2 = 0.3. The fluid flow regime inside the shell and coil is laminar, considering the range of Reynolds number Re = 500-2,000. This work is divided into two parts. The first section investigates how the location of the hot stream (coil side) inlet and outlet affects the heat exchanger's thermal performance, comparing different types of heat transfer fluid. The second part examines how the double coil's exterior helix diameter affects it. The outcomes revealed that the supreme thermal performance belongs to the model where the hot stream enters the exterior coil, and Water/MgO-TiO2 is the working fluid. This model exhibits more significant thermal performance than the model, with pure water as the hot stream entering the exterior coil by approximately 158.62 % at Re = 500. Moreover, at Re = 2,000, this model shows better thermal performance by around 51.72 % compared to the model with pure water. In light of the obtained outcomes from the second section of this work, the model with the external helix diameter of D1 = 240 mm illustrates the maximum thermal performance at Re = 500. Growth of the external helix diameter by about 33.34 % leads to augmentations in thermal performance by about 35.94 % and 42.86 % at Re = 500 and Re = 2,000, respectively.
引用
收藏
页数:19
相关论文
共 50 条
[21]   Numerical Study on Performance Characteristics of Exhaust Gas Properties in Channel and Coil Type Heat Exchanger [J].
Park, Jin Soo ;
Yu, I. Sang ;
Shin, Min Kyu ;
Oh, Jeong Hwa ;
Lee, Hee Jun ;
Ko, Young Sung .
TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2019, 43 (01) :1-9
[22]   NUMERICAL AND EXPERIMENTAL INVESTIGATION OF THE SHELL SIDE CHARACTERISTICS OF THE TREFOIL-HOLE BAFFLE HEAT EXCHANGER [J].
Wang, Dan ;
Wang, Ke ;
Wang, Yongqing ;
Bai, Caipeng ;
Liu, Minshan .
HEAT TRANSFER RESEARCH, 2017, 48 (01) :81-95
[23]   An experimental study of thermal performance of shell-and-coil heat exchangers [J].
Ghorbani, Nasser ;
Taherian, Hessam ;
Gorji, Mofid ;
Mirgolbabaei, Hessam .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (07) :775-781
[24]   Experimental Investigation of Coil Curvature Effect on Heat Transfer and Pressure Drop Characteristics of Shell and Coil Heat Exchanger [J].
Salem, M. R. ;
Elshazly, K. M. ;
Sakr, R. Y. ;
Ali, R. K. .
JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (01)
[25]   On the performance of a vertical helical coil heat exchanger. Numerical model and experimental validation [J].
Fernandez-Seara, Jose ;
Pineiro-Pontevedra, Carolina ;
Alberto Dopazo, J. .
APPLIED THERMAL ENGINEERING, 2014, 62 (02) :680-689
[26]   Exergy analysis of Shell and helical coil heat exchanger and design optimization [J].
Al-Abbas, Audai Hussein ;
Mohammed, Akeel Abbas ;
Hassoon, Atheer Saleh .
HEAT AND MASS TRANSFER, 2021, 57 (05) :797-806
[27]   Numerical investigations on the heat transfer characteristics of tube in tube helical coil heat exchanger [J].
Sheeba, A. ;
Mathew, P. ;
Prakash, Jose M. .
INTERNATIONAL CONFERENCE ON AEROSPACE AND MECHANICAL ENGINEERING, 2019, 1355
[28]   An in-depth numerical and experimental analysis of wire coil inserts: enhancing thermal performance and fluid flow characteristics in double pipe heat exchangers [J].
Ahirwar, Brajesh Kumar ;
Kumar, Arvind .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (23) :14057-14081
[29]   Numerical study on thermal performance of a BOG heat exchanger in the inclined condition [J].
Yan, Yan ;
Ni, Zhonghua ;
Zhi, Xiaoqin ;
Yin, Jingsong .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 34 :616-626
[30]   Effect of γ-Al2O3/water nanofluid on the thermal performance of shell and coil heat exchanger with different coil torsions [J].
K. M. Elshazly ;
R. Y. Sakr ;
R. K. Ali ;
M. R. Salem .