A single-stage purification method for the precise determination of zirconium isotopic composition in geological samples by double spike MC-ICP-MS

被引:0
|
作者
Feng, Lanping [1 ]
Wang, Chen [1 ]
Han, Yan [1 ]
Zhang, Wen [1 ]
Guo, Jing-Liang [1 ]
Zhou, Lian [1 ]
Hu, Zhaochu [1 ]
机构
[1] China Univ Geosci, Sch Earth Sci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
TODGA RESIN COLUMN; RATIO MEASUREMENTS; SEPARATION; ND; CA; FRACTIONATION; LU; HF;
D O I
10.1039/d4ja00332b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interest in studying zirconium (Zr) stable isotopic fractionation in both low and high-temperature environments has increased significantly in recent years. Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is the preferred technique for stable Zr isotope analysis due to its low sample consumption and high precision. However, the multi-column separation steps required to remove interferences and meet the stringent matrix requirements for Zr isotopes during MC-ICP-MS testing typically make the sample preparation process time-consuming. Here, we present a new, simple, and efficient single-pass chromatographic exchange technique for the chemical isolation of Zr from complex sample matrices. This new separation protocol is based on DGA resin and consists of only three elution steps and two types of acid eluents (15 mL 7 mol L-1 HNO3 and 5 mL 3 mol L-1 HNO3 + 0.1 mol L-1 HF), which afford straightforward separation of Zr with high yield, good purity, and low blank levels. Zr isotope ratios were measured using Neptune Plus MC-ICP-MS with the 91Zr-96Zr double spike in combination with standard-sample bracketing for mass bias correction. The validity of the proposed method is demonstrated by analyzing eight geological reference materials (including BCR-2, which has an extremely high Mo content of similar to 248 mu g g-1) with satisfactory results that are in good agreement with published values. Based on repeated analyses of pure standard solutions and geological reference materials, the long-term measurement reproducibility is better than +/- 0.048 parts per thousand for delta 94Zr. Therefore, the proposed method can be used for the rapid and efficient determination of stable Zr isotope ratios in geological samples.
引用
收藏
页码:3035 / 3047
页数:13
相关论文
共 50 条
  • [41] A rapid method of simultaneous chromatographic purification of Li and Mg for isotopic analyses using MC-ICP-MS
    Zhang, Wei
    Tanaka, Ryoji
    Kitagawa, Hiroshi
    Bohlin, Madeleine
    Nakamura, Eizo
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 480
  • [42] Determination of the Tin Stable Isotopic Composition in Tin-bearing Metals and Minerals by MC-ICP-MS
    Bruegmann, Gerhard
    Berger, Daniel
    Pernicka, Ernst
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2017, 41 (03) : 437 - 448
  • [43] A two-step chromatographic purification method for Ni for its isotopic analysis by MC-ICP-MS
    Li, Lingke
    Wu, Fei
    Liu, Yongsheng
    He, Tao
    Lin, Jie
    Zhang, Wen
    Li, Rui
    Chen, Haihong
    Zong, Keqing
    Zeng, Zhen
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (07) : 1938 - 1947
  • [44] Purification of boron using a combination of cationic and boron-specific resins and determination of boron isotopic composition in sediments by MC-ICP-MS
    Zhang, Ning
    Wen, Xue-Qin
    He, Mao-Yong
    Ren, Tongxiang
    Deng, Li
    Cheng, Yuanyuan
    Zhang, Xiaolin
    Guo, Junhua
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (05) : 1353 - 1360
  • [45] Ultra-precise titanium stable isotope measurements by double-spike high resolution MC-ICP-MS
    Millet, Marc-Alban
    Dauphas, Nicolas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) : 1444 - 1458
  • [46] Determination of Nd isotopic composition in seawater using newly developed solid phase extraction and MC-ICP-MS
    Tazoe, Hirofumi
    Amakawa, Hiroshi
    Suzuki, Katsuhiko
    Nishioka, Jun
    Hara, Takuya
    Obata, Hajime
    TALANTA, 2021, 232
  • [47] One-step chromatographic purification of K, Ca, and Sr from geological samples for high precision stable and radiogenic isotope analysis by MC-ICP-MS
    Li, Xiaoqiang
    Han, Guilin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (03) : 676 - 684
  • [48] Titanium Isotope Analysis of Igneous Reference Materials using a Double-spike MC-ICP-MS Method
    Li, Jin
    Tang, Suohan
    Zhu, Xiangkun
    Ma, Jianxiong
    Zhao, Xinmiao
    ACTA GEOLOGICA SINICA-ENGLISH EDITION, 2022, 96 (02) : 517 - 524
  • [49] Development of an analytical method for accurate and precise determination of rare earth element concentrations in geological materials using an MC-ICP-MS and group separation
    Lee, Seung-Gu
    Ko, Kyung-Seok
    FRONTIERS IN CHEMISTRY, 2023, 10
  • [50] A new double spike method for the determination of mass-dependent Te isotope compositions of meteorites and terrestrial materials by MC-ICP-MS
    Morton, Elin M.
    Kreissig, Katharina
    Coles, Barry J.
    Jaffe, Caris S.
    Martins, Rayssa
    Poole, Graeme M.
    Rehkaemper, Mark
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (06) : 1192 - 1204