A single-stage purification method for the precise determination of zirconium isotopic composition in geological samples by double spike MC-ICP-MS

被引:0
|
作者
Feng, Lanping [1 ]
Wang, Chen [1 ]
Han, Yan [1 ]
Zhang, Wen [1 ]
Guo, Jing-Liang [1 ]
Zhou, Lian [1 ]
Hu, Zhaochu [1 ]
机构
[1] China Univ Geosci, Sch Earth Sci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
TODGA RESIN COLUMN; RATIO MEASUREMENTS; SEPARATION; ND; CA; FRACTIONATION; LU; HF;
D O I
10.1039/d4ja00332b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interest in studying zirconium (Zr) stable isotopic fractionation in both low and high-temperature environments has increased significantly in recent years. Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is the preferred technique for stable Zr isotope analysis due to its low sample consumption and high precision. However, the multi-column separation steps required to remove interferences and meet the stringent matrix requirements for Zr isotopes during MC-ICP-MS testing typically make the sample preparation process time-consuming. Here, we present a new, simple, and efficient single-pass chromatographic exchange technique for the chemical isolation of Zr from complex sample matrices. This new separation protocol is based on DGA resin and consists of only three elution steps and two types of acid eluents (15 mL 7 mol L-1 HNO3 and 5 mL 3 mol L-1 HNO3 + 0.1 mol L-1 HF), which afford straightforward separation of Zr with high yield, good purity, and low blank levels. Zr isotope ratios were measured using Neptune Plus MC-ICP-MS with the 91Zr-96Zr double spike in combination with standard-sample bracketing for mass bias correction. The validity of the proposed method is demonstrated by analyzing eight geological reference materials (including BCR-2, which has an extremely high Mo content of similar to 248 mu g g-1) with satisfactory results that are in good agreement with published values. Based on repeated analyses of pure standard solutions and geological reference materials, the long-term measurement reproducibility is better than +/- 0.048 parts per thousand for delta 94Zr. Therefore, the proposed method can be used for the rapid and efficient determination of stable Zr isotope ratios in geological samples.
引用
收藏
页码:3035 / 3047
页数:13
相关论文
共 50 条
  • [31] Quantitative Separation of Molybdenum and Rhenium from Geological Materials for Isotopic Determination by MC-ICP-MS
    Pearce, Christopher R.
    Cohen, Anthony S.
    Parkinson, Ian J.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (02) : 219 - 229
  • [32] Chromatographic purification of Ca and Mg from biological and geological samples for isotope analysis by MC-ICP-MS
    Bao, Zhian
    Zong, Chunlei
    Chen, Kaiyun
    Lv, Nan
    Yuan, Honglin
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 448
  • [33] Stable W Isotope Measurements of Geological Reference Materials and Tungsten Ore Minerals by Double Spike MC-ICP-MS
    Zhang, Tianli
    Liu, Jia
    Zhang, Qun
    Zhang, Yingnan
    Qin, Liping
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (01) : 169 - 183
  • [34] A Highly Efficient Method for the Accurate and Precise Determination of Zinc Isotopic Ratios in Zinc-rich Minerals Using MC-ICP-MS
    Nie, Xiaojuan
    Bao, Zhian
    Liang, Peng
    Chen, Kaiyun
    Zong, Chunlei
    Yuan, Honglin
    ATOMIC SPECTROSCOPY, 2022, 43 (02) : 117 - 125
  • [35] A high performance method for the accurate and precise determination of silicon isotopic compositions in bulk silicate rock samples using laser ablation MC-ICP-MS
    Zhang, Chenxi
    Zhao, He
    Zhang, Wen
    Luo, Tao
    Li, Ming
    Zong, Keqing
    Liu, Yongsheng
    Hu, Zhaochu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (09) : 1887 - 1896
  • [36] A fast double-stack column chemical separation of Zn and Mo from geological samples for isotopic analysis by MC-ICP-MS
    Han, Yan
    Zhou, Lian
    Shi, Minghui
    Hu, Yating
    Zhang, Ge
    Hou, Xin
    Feng, Lanping
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (01) : 269 - 280
  • [37] Determination of thallium isotopic composition through MC-ICP-MS with mass bias corrected using admixed W
    Wang, Zhao-Yang
    Dong, Fei-Yu
    Yin, Lu
    Liu, Jun-Jie
    Zhong, Qiao-Hui
    Li, Jie
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (10) : 2443 - 2451
  • [38] High-precision double-spike Sn isotope analysis of geological materials by MC-ICP-MS
    She, Jia-Xin
    Li, Weiqiang
    An, Shichao
    Cai, Yuanfeng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (01) : 142 - 155
  • [39] Purification of Mg from extremely low-Mg felsic rocks for isotopic ratio determination by MC-ICP-MS
    Wang, Yang
    Zhang, Yinchu
    Li, Xin
    Ke, Shan
    Sun, Aiying
    Yang, Ruyi
    Yang, Weijuan
    He, Yongsheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (03) : 497 - 507
  • [40] Precise and accurate boron and lithium isotopic determinations for small sample-size geological materials by MC-ICP-MS
    Liu, Yung-Hsin
    Huang, Kuo-Fang
    Lee, Der-Chuen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 846 - 855