A single-stage purification method for the precise determination of zirconium isotopic composition in geological samples by double spike MC-ICP-MS

被引:0
|
作者
Feng, Lanping [1 ]
Wang, Chen [1 ]
Han, Yan [1 ]
Zhang, Wen [1 ]
Guo, Jing-Liang [1 ]
Zhou, Lian [1 ]
Hu, Zhaochu [1 ]
机构
[1] China Univ Geosci, Sch Earth Sci, State Key Lab Geol Proc & Mineral Resources, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
TODGA RESIN COLUMN; RATIO MEASUREMENTS; SEPARATION; ND; CA; FRACTIONATION; LU; HF;
D O I
10.1039/d4ja00332b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Interest in studying zirconium (Zr) stable isotopic fractionation in both low and high-temperature environments has increased significantly in recent years. Multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) is the preferred technique for stable Zr isotope analysis due to its low sample consumption and high precision. However, the multi-column separation steps required to remove interferences and meet the stringent matrix requirements for Zr isotopes during MC-ICP-MS testing typically make the sample preparation process time-consuming. Here, we present a new, simple, and efficient single-pass chromatographic exchange technique for the chemical isolation of Zr from complex sample matrices. This new separation protocol is based on DGA resin and consists of only three elution steps and two types of acid eluents (15 mL 7 mol L-1 HNO3 and 5 mL 3 mol L-1 HNO3 + 0.1 mol L-1 HF), which afford straightforward separation of Zr with high yield, good purity, and low blank levels. Zr isotope ratios were measured using Neptune Plus MC-ICP-MS with the 91Zr-96Zr double spike in combination with standard-sample bracketing for mass bias correction. The validity of the proposed method is demonstrated by analyzing eight geological reference materials (including BCR-2, which has an extremely high Mo content of similar to 248 mu g g-1) with satisfactory results that are in good agreement with published values. Based on repeated analyses of pure standard solutions and geological reference materials, the long-term measurement reproducibility is better than +/- 0.048 parts per thousand for delta 94Zr. Therefore, the proposed method can be used for the rapid and efficient determination of stable Zr isotope ratios in geological samples.
引用
收藏
页码:3035 / 3047
页数:13
相关论文
共 50 条
  • [21] A Revisited Purification of Li for 'Na Breakthrough' and its Isotopic Determination by MC-ICP-MS
    Xu, Lin
    Luo, Chongguang
    Wen, Hanjie
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (01) : 201 - 214
  • [22] Effects of different cone combinations on accurate and precise determination of Li isotopic composition by MC-ICP-MS
    Gou, Long-Fei
    Jin, Zhang-Dong
    Deng, Li
    He, Mao-Yong
    Liu, Chun-Yao
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 146 : 1 - 8
  • [23] Determination of the zirconium isotopic composition of the new isotopic standard NRC ZIRC-1 using MC-ICP-MS
    Tian, Shengyu
    Moynier, Frederic
    Inglis, Edward C.
    Jensen, Ninna K.
    Deng, Zhengbin
    Schiller, Martin
    Bizzarro, Martin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (03) : 656 - 662
  • [24] Precise determination of δ88/86Sr in natural samples by double-spike MC-ICP-MS and its TIMS verification
    Shalev, Netta
    Segal, Irena
    Lazar, Boaz
    Gavrieli, Ittai
    Fietzke, Jan
    Eisenhauer, Anton
    Halicz, Ludwik
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (06) : 940 - 944
  • [25] Determination of the Isotopic Composition of Ytterbium by MC-ICP-MS Using an Optimized Regression Model
    Lin, Ran
    Lin, Jie
    Zong, Keqing
    Yang, Ao
    Chen, Kang
    Liu, Yongsheng
    Hu, Zhaochu
    ANALYTICAL CHEMISTRY, 2022, 94 (20) : 7200 - 7209
  • [26] A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Tan, Decan
    Wang, Shui-Jiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1639 - 1651
  • [27] An efficient Cd two-stage column system for high-precision determination of Cd isotopic compositions by double spike MC-ICP-MS
    Zhang, Zheyuan
    Li, Tao
    Li, Baichan
    Lin, Yibo
    Li, Gaojun
    Chen, Tianyu
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (04) : 1142 - 1151
  • [28] A simplified dual-column system for Li purification and isotopic analysis of geological materials by MC-ICP-MS
    Hu, Wenjie
    Chen, Lu
    Geng, Xianlei
    Liang, Zhengwei
    Tian, Shihong
    TALANTA, 2025, 283
  • [29] An improved method of Cr purification for high precision measurement of Cr isotopes by double spike MC-ICP-MS
    Zhu, Jian-Ming
    Wu, Guangliang
    Wang, Xiangli
    Han, Guilin
    Zhang, Lixin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (05) : 809 - 821
  • [30] A new method of Sn purification and isotopic determination with a double-spike technique for geological and cosmochemical samples
    Wang, Xueying
    Fitoussi, Caroline
    Bourdon, Bernard
    Amet, Quentin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (05) : 1009 - 1019