PROGRESSIVE COLLAPSE PERFORMANCE OF PRESTRESSED CONCRETE FRAMES UNDER PENULTIMATE COLUMN REMOVAL SCENARIO

被引:0
|
作者
Lan D.-Q. [1 ]
Deng X.-F. [1 ,2 ]
Jin L. [1 ]
Qian K. [2 ]
机构
[1] Key Laboratory of Urban Security and Disaster Engineering, Beijing University of Technology, Beijing
[2] Guangxi Key Laboratory of New Energy and Building Energy Saving, Guilin University of Technology, Guilin University of Technology, Guangxi, Guilin
来源
Gongcheng Lixue/Engineering Mechanics | 2023年 / 40卷 / 10期
关键词
experimental study; numerical analysis; penultimate column failure; prestressed structure; progressive collapse;
D O I
10.6052/j.issn.1000-4750.2022.01.0052
中图分类号
学科分类号
摘要
Considering that the direction of bending moment at the beam end nearby the removed column will reverse, which may disagree with the profile of prestressing strands. Thus, the prestressed concrete frame may have high vulnerability for progressive collapse. In this study, experimental and numerical studies were performed to study the performance of unbonded prestressed concrete (PC) beam-column sub-assemblies subjected to a penultimate column removal scenario to resist progressive collapse. Two half-scale PC beam-column sub-assemblies with different strand profiles were tested by Pushdown loading procedure. Failure modes, the involution of load resisting mechanisms, and ultimate load resistance were analyzed. To quantify the effect of the strand, a non-prestressed reinforced concrete beam-column sub-assembly was designed, the geometrical dimension and reinforcement ratio of which were consistent with the PC beam-column sub-assemblies. It is found that the presence of the strand leads to a greater load resistance, lower deformation capacity and different failure modes. The considerable tension in the strand cause significant second-order effects in the side column, leading to large eccentric compression failure. To further study the performance of PC frames against their progressive collapse, high-fidelity numerical models built by LS-DYNA were used to conduct a series of parameter studies. It is found that prestress forces can increase compressive an arch action. The strand can significantly enhance the ultimate load resistance at a large deformation stage. © 2023 Tsinghua University. All rights reserved.
引用
收藏
页码:58 / 70
页数:12
相关论文
共 40 条
  • [31] ZHOU Yun, CHEN Taiping, HU Xiang, Et al., progressive collapse resistance of RC frame structures considering surrounding structural constraints, Engineering Mechanics, 36, 1, pp. 216-226, (2019)
  • [32] ZHANG Youjia, WANG Chong, DU Ke, Numerical study on the vertical collapse capacity of RC spatial beam-slab structures with unequal spans, Engineering Mechanics, 39, 1, pp. 139-150, (2022)
  • [33] QIAN K, LIU Y, YANG T, Et al., Progressive collapse resistance of posttensioned concrete beam-column subassemblages with unbonded posttensioning strands, Journal of Structural Engineering, 144, (2018)
  • [34] QIAN K, ZHANG X D, FU F, Et al., Progressive collapse-resisting mechanisms of planar prestressed concrete frame, ACI Structural Journal, 116, 4, pp. 77-90, (2019)
  • [35] YU Yang, LI Zhi, XIAO Longshan, Et al., Load resisting mechanism of precast structure under exterior column failure, Engineering Mechanics, 38, 4, pp. 159-168, (2021)
  • [36] YANG Tao, CHEN Wanqing, HAO Tianzhi, Experimental study on dynamic collapse performance of prestressed RC frame substructures after middle column demolition, Journal of Vibration and Shock, 39, 20, pp. 18-23, (2020)
  • [37] JIN Liu, LAN Dongqiu, DENG Xiaofang, Et al., Study on progressive collapse mechanisms of unbonded prestressed beam-column sub-assemblages, Journal of Building Structures, pp. 1-12
  • [38] GB 50010-2010, Code for design of concrete structures, (2015)
  • [39] JGJ 369-2016, Code for design of prestressed concrete structures, (2016)
  • [40] Building code requirements for structural concrete (ACI 318-14) and Commentary (318R-14), (2014)