PROGRESSIVE COLLAPSE PERFORMANCE OF PRESTRESSED CONCRETE FRAMES UNDER PENULTIMATE COLUMN REMOVAL SCENARIO

被引:0
|
作者
Lan D.-Q. [1 ]
Deng X.-F. [1 ,2 ]
Jin L. [1 ]
Qian K. [2 ]
机构
[1] Key Laboratory of Urban Security and Disaster Engineering, Beijing University of Technology, Beijing
[2] Guangxi Key Laboratory of New Energy and Building Energy Saving, Guilin University of Technology, Guilin University of Technology, Guangxi, Guilin
来源
Gongcheng Lixue/Engineering Mechanics | 2023年 / 40卷 / 10期
关键词
experimental study; numerical analysis; penultimate column failure; prestressed structure; progressive collapse;
D O I
10.6052/j.issn.1000-4750.2022.01.0052
中图分类号
学科分类号
摘要
Considering that the direction of bending moment at the beam end nearby the removed column will reverse, which may disagree with the profile of prestressing strands. Thus, the prestressed concrete frame may have high vulnerability for progressive collapse. In this study, experimental and numerical studies were performed to study the performance of unbonded prestressed concrete (PC) beam-column sub-assemblies subjected to a penultimate column removal scenario to resist progressive collapse. Two half-scale PC beam-column sub-assemblies with different strand profiles were tested by Pushdown loading procedure. Failure modes, the involution of load resisting mechanisms, and ultimate load resistance were analyzed. To quantify the effect of the strand, a non-prestressed reinforced concrete beam-column sub-assembly was designed, the geometrical dimension and reinforcement ratio of which were consistent with the PC beam-column sub-assemblies. It is found that the presence of the strand leads to a greater load resistance, lower deformation capacity and different failure modes. The considerable tension in the strand cause significant second-order effects in the side column, leading to large eccentric compression failure. To further study the performance of PC frames against their progressive collapse, high-fidelity numerical models built by LS-DYNA were used to conduct a series of parameter studies. It is found that prestress forces can increase compressive an arch action. The strand can significantly enhance the ultimate load resistance at a large deformation stage. © 2023 Tsinghua University. All rights reserved.
引用
收藏
页码:58 / 70
页数:12
相关论文
共 40 条
  • [1] LU Xinzheng, LI Yi, YE Lieping, Et al., Study on design method to resist progressive collapse for reinforced concrete frames, Engineering Mechanics, 25, 2, pp. 150-157, (2008)
  • [2] UFC 4-023-03, Design of structures to resist progressive collapse, (2005)
  • [3] BS 8110-1: 1997, Structural use of concrete: Part 1: Code of practice for design and construction, (2002)
  • [4] EN 1991-1-7: Eurocode 1: Actions on Structures: Part 1-7: Accidental Actions, (2006)
  • [5] Progressive collapse analysis and design guidelines for new federal office buildings and major modernization project, (2005)
  • [6] YI W J, HE Q F, XIAO Y, Et al., Experimental study on progressive collapse-resistant behavior of reinforced concrete frame structures, ACI Structural Journal, 105, 4, pp. 433-439, (2008)
  • [7] XIAO Yuzhe, LI Yi, LU Xinzheng, Et al., Experimental study on the dynamic effects in progressive collapse of beam-column concrete structures, Engineering Mechanics, 36, 5, pp. 44-52, (2019)
  • [8] CHEN Zefan, LIN Kaiqi, LU Xinzheng, Et al., Uncertainty. analysis on progressive collapse resistance of RC beam-column substructures, Engineering Mechanics, 38, 6, pp. 72-80, (2021)
  • [9] STINGER S M, ORTON S L., Experimental evaluation of disproportionate collapse resistance in reinforced concrete frames, ACI Structural Journal, 110, 3, pp. 521-530, (2013)
  • [10] YU J, TAN K H., Structural behavior of RC beam-column subassemblages under a middle column removal scenario, Journal of Structural Engineering, 139, 2, pp. 233-250, (2012)