Characteristics of fine particle formation during combustion of high-alkali coal in a new full-scale circulating fluidized bed boiler
被引:0
|作者:
Xu, Meng
[1
]
Wang, Jianjiang
[1
]
Wei, Bo
[1
]
Liu, Kunpeng
[1
]
Ruan, Renhui
[2
]
Wang, Yibin
[2
]
Tan, Houzhang
[2
]
Zhu, Quan
[3
]
Wang, Shihai
[1
]
机构:
[1] Xinjiang Univ, State Key Lab Chem & Utilizat Carbon Based Energy, Urumqi 830017, Xinjiang, Peoples R China
[2] Xi An Jiao Tong Univ, Dept Thermal Engn, MOE Key Lab Thermo Fluid Sci & Engn, Xian 710049, Peoples R China
[3] Sichuan Univ, Sch Chem Engn, Chengdu 610065, Peoples R China
基金:
中国国家自然科学基金;
关键词:
High-alkali coal;
Particulate matter;
Full-scale CFB;
Flue gas temperature;
SUBMICRON PARTICULATE MATTER;
HIGH-TEMPERATURE CORROSION;
ZHUNDONG COAL;
ASH DEPOSITION;
EARTH METALS;
SODIUM;
FRAGMENTATION;
LIGNITE;
MECHANISM;
CALCIUM;
D O I:
10.1016/j.joei.2024.101631
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
High-alkali coal generated an increased number of fine particles during the combustion process. Understanding the transformative characteristics of particulate matter (PM) in a full-scale boiler that burns 100 % Zhundong (ZD) coal is key for controlling pollutant emissions. This paper investigated PM formation in a novel full-scale Circulating Fluidized Bed (CFB) boiler. PM samples were collected from various points along the steam-cooled flue at 50 %, 67 %, and 100 % boiler load. Utilizing Low-pressure impactors and scanning electron microscopy coupled with energy disperse spectroscopy (SEM-EDS) were applied to analyze the mass-based particle size distribution(MPSD), elemental compositions, and morphology of PM. The results show that sub-micron particles produced under low boiler load consist primarily of AAEMs sulfates, whereas under high load, they consist primarily of alkali metal chlorides. Super-micron particles are predominantly sulfates and silicates. The concentrations of Na, K, and Cl in PM0.4 decreased as the flue gas cooled down in the steam-flue of the CFB. At 100 % boiler load, Na, K, Cl and S account for more than 90 % of the total elements in the sub-micron particles. However, these four elements demonstrated a 25 % decrease at a boiler load of 67 % compared to 100 % load. Interestingly, the compositions of super-micron particles seemed to be minimally affected by the boiler load.