Detection Method of Interturn Short-circuit Faults in Oil-immersed Transformers Based on Fusion Analysis of Electrothermal Characteristic

被引:0
作者
Zhang L. [1 ]
Sheng G. [1 ]
Hou H. [1 ]
Jiang X. [1 ]
机构
[1] Department of Electrical Engineering, Shanghai Jiao Tong University, Minhang District, Shanghai
来源
Dianwang Jishu/Power System Technology | 2021年 / 45卷 / 07期
基金
中国国家自然科学基金;
关键词
Digital twin; Electrothermal characteristic; Fault detection; Interturn short circuit; Oil-immersed transformer;
D O I
10.13335/j.1000-3673.pst.2020.2054
中图分类号
学科分类号
摘要
The existing methods of interturn fault diagnosis of a power transformer depend on the single signal indicator such as the winding current, the impendence or the dissolved gases etc., so that they can not accurately detect the exact location of the faults, especially the short circuit with a few turns. Taking the winding current, winding hot spot temperature and oil temperature into consideration, a new approach based on the fusion analysis of electrothermal characteristics is proposed to detect the interturn faults in the winding of an oil-immersed transformer. The main idea of the proposed method is to establish the digital space model of the physical transformer with the digital twin technology. Then, multi-physics simulation is used to derive the changing law of the electrothermal characteristics of the transformers under different operation conditions and interturn fault types in the digital space. With the main electrothermal characteristics parameters including winding current and hot spot temperature as the features, a twin fault sample based data-driven model is presented for the interturn fault detection. A case study is carried out on the 31.5MVA/110kV power transformer. The results show that the proposed detection method based on the fusion analysis of the electrothermal characteristic can effectively identify the early latent interturn fault of the power transformer. The overall accuracy of the proposed method can reach 94%. © 2021, Power System Technology Press. All right reserved.
引用
收藏
页码:2473 / 2482
页数:9
相关论文
共 27 条
[1]  
BARZEGARAN M R, MIRZAIE M., Detecting the position of winding short circuit faults in transformer using high frequency analysis, European Journal of Scientific Research, 23, 4, pp. 645-659, (2008)
[2]  
BUTLER K L, KUFORIJI A., Experimental results from short-circuit faults on a distribution transformer, 2001 IEEE/PES Transmission and Distribution Conference and Exposition, pp. 299-306, (2001)
[3]  
FAIZ J, SOLEIMANI M., Dissolved gas analysis evaluation in electric power transformers using conventional methods a review, IEEE Transactions on Dielectrics and Electrical Insulation, 24, 2, pp. 1239-1248, (2017)
[4]  
PAN Chao, SHI Wenxin, MENG Tao, Study on electromagnetic characteristics of interturn short circuit of single-phase transformer, High Voltage Engineering, 46, 5, pp. 1839-1856, (2020)
[5]  
QIAN Guochao, WANG Fenghua, WANG Shaojing, Et al., Experimental research of vibration frequency response features of transformer winding, High Voltage Engineering, 44, 3, pp. 821-826, (2018)
[6]  
SOLEIMANI M, FAIZ J, NASAB P S, Et al., Temperature measuring based decision making prognostic approach in electric power transformers winding failures, IEEE Transactions on Instrumentation and Measurement, (2020)
[7]  
LIANG Z, ZHEN X, NIU S., DC resistance measurement for low voltage side winding of large-scale transformer, Electric Power Automation Equipment, 27, 6, pp. 27-30, (2007)
[8]  
ASADI N, KELK H M., Modeling, analysis, and detection of internal winding faults in power transformers, IEEE transactions on Power Delivery, 30, 6, pp. 2419-2426, (2015)
[9]  
XIONG Xiaofu, WANG Qiang, CHEN Xingtian, A protection method of transformer inter-turn short circuit based on the variation of current ratio, Power System Protection and Control, 41, 9, pp. 112-115, (2013)
[10]  
BUTLER-PURRY K L, BAGRIYANIK M., Characterization of transients in transformers using discrete wavelet transforms, IEEE Transactions on Power Systems, 18, 2, pp. 648-656, (2003)