The Effects of Intensity, Exposure Time, and Distance of Polymerization Light on Vickers Microhardness and Temperature Rise of Conventional Resin-Based Composite

被引:2
作者
Duratbegovic, Damir [1 ]
Pervan, Nedim [2 ]
Jakupovic, Selma [3 ]
Kobaslija, Sedin [1 ]
机构
[1] Univ Sarajevo, Fac Dent, Dept Pediat & Prevent Dent, Dent Clin Ctr, Sarajevo 71000, Bosnia & Herceg
[2] Univ Sarajevo, Fac Mech Engn, Dept Mech Design, Sarajevo 71000, Bosnia & Herceg
[3] Univ Sarajevo, Fac Dent, Dept Restorat Dent & Endodont, Dent Clin Ctr, Sarajevo 71000, Bosnia & Herceg
关键词
dental resin-based composites; curing light intensity; distance; exposure time; microhardness; temperature rise; BULK-FILL RESIN; CURING UNITS; EMITTING DIODE; IRRADIANCE; HALOGEN; CONVERSION; DEVICES; PERFORMANCE; EFFICIENCY; INCREASE;
D O I
10.3390/polym16223175
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
(1) Background: This study investigates the effects of curing light intensity, exposure time, and distance on the Vickers microhardness (VMH), hardness bottom-to-top ratio (HR), and temperature rise (TR) of conventional dental resin-based composite (RBC). (2) Materials and Methods: Specimens of one conventional RBC (Tetric EvoCeram, Ivoclar Vivadent) were cured with 12 different curing protocols (CPs), created with three different light intensities (Quartz Tungsten Halogen 300 mW/cm(2), LED 650 mW/cm(2), LED 1100 mW/cm(2)), two exposure times (20 and 40 s), and two distances of curing tip (0 and 8 mm). The VMH of top (VMH-T) and bottom (VMH-B) surfaces was measured. The hardness bottom-to-top ratio (HR) was calculated from VMH-B and VMH-T. The HR below 80% was rated as inadequate polymerization. The TR at the depth of 2 mm within the RBC was measured using a K-type thermocouple. Data were analyzed using Levene's test and the multivariate analysis of variance (MANOVA). The level of significance was set at p < 0.05. (3) Results: Exposure time and distance significantly influenced VMH-B and HR. Increased distance significantly reduced VMH-B, HR, and TR. CPs 300 mW/cm(2)/8 mm/20 s and 650 mW/cm(2)/8 mm/20 s produced inadequate polymerization (HR < 80%). Prolonged exposure time produced higher values of VMH-B and HR. The TR was significantly influenced by light intensity and distance. (4) Conclusions: Suboptimal light intensity (<800 mW/cm(2)) can produce inadequate polymerization at the lower side of the composite layer when used from a distance. Prolonged irradiation can improve the polymerization to a certain extent. Clinicians are advised to monitor the intensity of the LCUs in order to optimize the photopolymerization process. Caution is required when polymerizing with high-intensity curing light in direct contact with the RBC with longer exposure times than recommended.
引用
收藏
页数:20
相关论文
共 75 条
  • [1] Aguiar Flávio Henrique Baggio, 2005, Braz. oral res., V19, P302
  • [2] Influence of Light-Curing Mode on the Mechanical Properties of Dental Resin Nanocomposites
    Aljosa, Ivanisevic
    Tijana, Lainovic
    Larisa, Blazic
    Marko, Vilotic
    [J]. 24TH DAAAM INTERNATIONAL SYMPOSIUM ON INTELLIGENT MANUFACTURING AND AUTOMATION, 2013, 2014, 69 : 921 - 930
  • [3] Alqabbaa Lama Mana, 2018, J Conserv Dent, V21, P667, DOI 10.4103/JCD.JCD_252_18
  • [4] Types of polymerisation units and their intensity output in private dental clinics of twin cities in eastern province, KSA; a pilot study
    Alquria, Theeb
    Al Gady, Mohammed
    Khabeer, Abdul
    Ali, Saqib
    [J]. JOURNAL OF TAIBAH UNIVERSITY MEDICAL SCIENCES, 2019, 14 (01): : 47 - 51
  • [5] AlShaafi MM, 2017, SAUDI DENT J, V29, P48, DOI 10.1016/j.sdentj.2017.01.002
  • [6] Altaie A, 2021, OPER DENT, V46, P271, DOI [10.2341/20-092-C, 10.2341/20-092-LIT]
  • [7] Stability of the Light Output, Oral Cavity Tip Accessibility in Posterior Region and Emission Spectrum of Light-Curing Units
    Andre, C. B.
    Nima, G.
    Sebold, M.
    Giannini, M.
    Price, R. B.
    [J]. OPERATIVE DENTISTRY, 2018, 43 (04) : 398 - 407
  • [8] Ashfaq Ahmed Usman, 2021, J Ayub Med Coll Abbottabad, V33(Suppl 1), pS769
  • [9] Temperature rise induced by some light emitting diode and quartz-tungsten-halogen curing units
    Asmussen, E
    Peutzfeldt, A
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (01) : 96 - 98
  • [10] Influence of LED irradiance on flexural properties and Vickers hardness of resin-based composite materials
    Bhamra, G. S.
    Fleming, G. J. P.
    Darvell, B. W.
    [J]. DENTAL MATERIALS, 2010, 26 (02) : 148 - 155