Study on Human Perception Experiments and Design Limits of the Hybrid Electric Field of Parallel HVAC and HVDC Transmission Lines

被引:0
|
作者
Xie L. [1 ]
Lu J. [1 ]
Yang Y. [2 ]
Wu G. [1 ]
Ju Y. [1 ]
机构
[1] China Electric Power Research Institute, Haidian District, Beijing
[2] Henan University of Technology, Henan Province, Zhengzhou
关键词
design limit; head hair perception of human; HVDC transmission line; hybrid electric field; parallel HVAC; spark discharge perception of human;
D O I
10.13334/j.0258-8013.pcsee.230774
中图分类号
学科分类号
摘要
With the development of power grid in China, it is an optimized transmission configuration to lay parallel HVAC and HVDC lines in an adjacent corridor or on a same tower. However, the corresponding design standard to limit the hybrid electric field of the transmission lines, which is the basis to design the height of the conductors to ground and the width of the corridor, has not been proposed. The principles to determine the limit of hybrid electric field are discussed and recommended. Then, two types of human perception, head hair perception and spark discharge perception, are measured under hybrid electric field with different DC and AC (power frequency) components. According to the statistical results of the experiment data, the relationship curves between AC (power frequency) electric field and DC electric field are derived when the human sensation is acceptable under some certain probabilities. Based on these curves, the formulas to calculate the design limit of the hybrid electric field are obtained. The results in the research can provide technical support to control the hybrid electric field for design of the parallel HVAC and HVDC transmission lines. © 2024 Chin.Soc.for Elec.Eng.
引用
收藏
页码:776 / 789
页数:13
相关论文
共 24 条
  • [1] LIU Zhenya, Ultra-high voltage AC & DC grid [M].Beijing:China Electric Power Press, pp. 240-246, (2013)
  • [2] SUN Xin, CHEN Weijiang, LU Jiayu, Environmental impact assessment of AC electric power transmission and transformation project [M], pp. 115-123, (2015)
  • [3] MARUVADA P S, DROGI S., Field and ion interactions of hybrid AC/DC transmission lines[J], IEEE Transactions on Power Delivery, 3, 3, pp. 1165-1172, (1988)
  • [4] ZHAO Tiebin, KASTEN D G., Calculation of single phase AC and monopolar DC hybrid corona effects[J], IEEE Transactions on Power Delivery, 11, 3, pp. 1454-1463, (1996)
  • [5] WU Guifang, YUAN Chunfeng, LU Jiayu, Calculation on electromagnetic environment of UHVDC and EHVAC transmission lines erected in a common corridor[J], Power System Technology, 34, 2, pp. 14-19, (2010)
  • [6] Yong YANG, Jiayu LU, Yinzhao LEI, A calculation method for the hybrid electric field under UHVAC and UHVDC transmission lines in the same corridor[J], IEEE Transactions on Power Delivery, 25, 2, pp. 1146-1153, (2010)
  • [7] ZHOU Xiangxian, LU Tiebing, Corona loss analysis of high voltage DC transmission lines in close proximity of high voltage AC transmission lines[J], Proceedings of the CSEE, 31, 31, pp. 211-218, (2011)
  • [8] LI W,, ZHANG Bo, Jinliang HE, Calculation of the ion flow field of AC-DC hybrid transmission lines[J], IET Generation,Transmission & Distribution, 3, 10, pp. 911-918, (2009)
  • [9] Ji QIAO, ZOU Jun, YUAN Jiansheng, Electric field calculation of HVAC and HVDC transmission lines on the same tower with domain decomposition method and high order element[J], Power System Technology, 41, 1, pp. 335-341, (2017)
  • [10] Ministry of Housing and Urban-Rural Development of the People’s Republic of China.GB 50790—2013 Code for designing of ±800kV DC overhead transmission line, (2013)