Mechanical Stability Influenced by Assembly Errors of a 0.5 T Mobile MRI Superconducting Magnet

被引:0
作者
Yao, Lianhao [1 ]
Qu, Hongyi [2 ]
Wang, Hui [2 ]
Wu, Huafang [3 ]
Liu, Jianhua [2 ]
机构
[1] Nanchang Univ, Adv Mfg Sch, Nanchang 330031, Peoples R China
[2] Chinese Acad Sci, Inst Elect Engn, Beijing 100190, Peoples R China
[3] Chinese Acad Sci, Ganjiang Innovat Acad, Ganzhou 341000, Peoples R China
关键词
Superconducting magnets; Assembly; Stress; Magnetic resonance imaging; Parallel processing; Electromagnetic forces; Magnetomechanical effects; Superconducting magnet structure; mobile MRI; assembly error; electromagnetic force; SYSTEM; FIELD;
D O I
10.1109/TASC.2024.3420320
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Mobile MRI makes it easier to perform MRI in settings with limited resources, which improves imaging accessibility in a greater range of contexts. We present a design for an open superconducting magnet structure that is lightweight and specifically suited for mobile MRI systems in order to further the development of MRI technology. Additionally, based on superconducting magnet manufacturing and assembly tolerance requirements and engineering experience, this study parameterizes the assembly errors of large-gap superconducting magnets, including parallelism errors and translation errors. The comparative simulation analysis revealed that certain areas of superconducting magnet will experience an increase in equivalent stress due to assembly errors. Specifically, the stress increase was particularly pronounced at the junctures between the support structure and both the upper and lower support plates, as well as at the barrel and support plate junction's annular area, where tension fluctuations were noticeable. In contrast, equivalent stress changes in other areas of the magnet were not obvious, indicating a low sensitivity to assembly errors in these areas. The outcomes of this study provide a reference for the design and optimization of lightweight and open superconducting magnet structures, contributing to the safety and reliability of mobile MRI systems.
引用
收藏
页数:5
相关论文
共 18 条
  • [11] Novel technologies and configurations of superconducting magnets for MRI
    Lvovsky, Yuri
    Stautner, Ernst Wolfgang
    Zhang, Tao
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2013, 26 (09)
  • [12] Progress in MRI magnets
    Morrow, G
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 744 - 751
  • [13] Development of a small car-mounted magnetic resonance imaging system for human elbows using a 0.2 T permanent magnet
    Nakagomi, Mayu
    Kajiwara, Michiru
    Matsuzaki, Jumpei
    Tanabe, Katsumasa
    Hoshiai, Sodai
    Okamoto, Yoshikazu
    Terada, Yasuhiko
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2019, 304 : 1 - 6
  • [14] Relative position computation for assembly planning with planar toleranced parts
    Ostrovsky-Berman, Y
    Joskowicz, L
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2006, 25 (02) : 147 - 170
  • [15] Ren ZH, 2017, PR ELECTROMAGN RES S, P3042, DOI 10.1109/PIERS-FALL.2017.8293655
  • [16] Study on magnetic field deviation due to manufacturing errors of the SIS100 superconducting dipole magnet
    Sugita, Kei
    Fischer, Egbert
    Mierau, Anna
    Roux, Christian
    Schnizer, Pierre
    [J]. CRYOGENICS, 2016, 80 : 385 - 389
  • [17] Estimation of magnetic error field with alleviating fabrication tolerance of large superconducting magnets on JA DEMO reactor
    Utoh, Hiroyasu
    Matsunaga, Go
    Hiwatari, Ryoji
    Sakamoto, Yoshiteru
    Tobita, Kenji
    [J]. FUSION ENGINEERING AND DESIGN, 2020, 161
  • [18] Effect of low-temperature on mechanical behavior for an AISI 304 austenitic stainless steel
    Zheng, Chengsi
    Yu, Wangwei
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2018, 710 : 359 - 365