Design and Fabrication of a Capacitive Sensor for the Detection of Formaldehyde in Fish at Room Temperature

被引:0
|
作者
Biswas, Bedabrata [1 ]
Yadav, Mrigendra [2 ]
Pratim Sahu, Partha [2 ]
Talukdar, F. A. [1 ]
Baghel, Gaurav Singh [1 ]
机构
[1] Natl Inst Technol Silchar, Dept Elect & Commun Engn, Silchar 788010, Assam, India
[2] Tezpur Univ, Dept Elect & Commun Engn, Tezpur 784028, Assam, India
关键词
fish freshness; Capacitive sensor; formalin sensor; portable sensor; metal-insulator-semiconductor (MIS) sensor; reduced graphene oxide (rGO)-based sensor; GAS SENSOR; OXIDATION;
D O I
10.1109/JSEN.2024.3465238
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traders and suppliers have been artificially extending the shelf life of raw fish using formaldehyde (HCHO). This practice leads to significant health risks, including renal injury, nasopharyngeal cancer, and severe abdominal pain after consuming cooked fish contaminated with formaldehyde. Consequently, detecting formaldehyde in fish has become a critical area of research. A portable metal-insulator-semiconductor (MIS) capacitive sensor ( $20\times 20$ mm) with a silver (Ag) metal patch electrode has been fabricated for rapid detection of formaldehyde from formalin-treated raw fish. Here, reduced graphene oxide (rGO) is used as a sensing material deposited on $\text {SiO}_{{2}}/\text {Si}$ wafer to increase the effective sensing interaction area. An Ag-spot electrode was printed on top of the sensing layer using a thermal deposition technique using a hard mask. The sensor calibration was carried out using known concentrations of volatile formaldehyde. The sensor stands out with its innovative capacitive design, elevating sensitivity beyond conventional approaches. The sensor has shown a sensitivity of 142.1 pf/ppm and response of 120% at 0.5 ppm with a limit of detection (LoD) of 0.5 ppm. This unique design not only simplifies fabrication but also guarantees both high sensitivity and reliability. The results of the study indicate that the sensor system effectively and rapidly (85 s) detects formalin-treated fish at room temperature (300 K). The portable and cost-effective nature of the device assures on-site measurement of formalin in fresh raw fish.
引用
收藏
页码:36377 / 36385
页数:9
相关论文
共 50 条
  • [31] Room temperature operating formaldehyde sensor based on n-type ZnO functionalized surface acoustic wave resonator
    Singh, Jitendra
    Gupta, Saurabh Kumar
    Vinita
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 365
  • [32] Fabrication of Room Temperature Resistive Ethanol Gas Sensor Based on ZnO Nanorods Decorated with PbS Nanoparticles
    Madvar, Hadi Riyahi
    Kordrostami, Zoheir
    Hamedi, Samaneh
    JOURNAL OF NANO RESEARCH, 2020, 65 : 145 - 155
  • [33] Simulation of a novel capacitive sensor for rebar corrosion detection
    Cheng, Yu
    Hanif, Asad
    Chen, E.
    Ma, Guancong
    Li, Zongjin
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 174 : 613 - 624
  • [34] A CMOS Micromachined Capacitive Sensor Array for Fingerprint Detection
    Liu, Jiun-Chieh
    Hsiung, Yung-Shih
    Lu, Michael S. -C.
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1004 - 1010
  • [35] Design of Thin Film Capacitive Sensor for Flow Measurement
    Kumaresh, K. J.
    Raj, P. Deepak
    Sridharan, M.
    MATERIALS TODAY-PROCEEDINGS, 2016, 3 (06) : 1517 - 1524
  • [36] Design and performance of integrated capacitive sensor based on knitting
    Li, Luhong
    Luo, Tian
    Cong, Honglian
    Fangzhi Xuebao/Journal of Textile Research, 2024, 45 (10): : 80 - 88
  • [37] Study on Design Optimization of a Capacitive Tilt Angle Sensor
    Ha Tran Thi Thuy
    Hai Nguyen Dac
    Tuan Vu Quoc
    Pham, Thinh Quoc
    An Nguyen Ngoc
    Trinh Chu Duc
    Tung Thanh Bui
    IETE JOURNAL OF RESEARCH, 2022, 68 (02) : 1427 - 1434
  • [38] Design, fabrication, and characterization of out-of-plane W-form microsprings for vertical comb electrodes capacitive sensor
    Chuang, Chieh-Tang
    Chen, Rongshun
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2009, 8 (03):
  • [39] A Novel Porous Silicon Composite Sensor for Formaldehyde Detection
    Wang Wei
    Gao Yang
    Tao Qiang
    Liu Ying-Zi
    Zuo Juan-Juan
    Ju Xiao-Cui
    Zhang Juan-Kun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (06) : 849 - 855
  • [40] Flexible In2Se3 sensor for chemiresistive NO2 detection at room temperature
    Fan, Shilei
    Lu, Guocai
    Hu, Yinhua
    Zheng, Wei
    Liu, Xianghong
    Zhang, Jun
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 396