Cascade control mode of indoor temperature PIλDµ and supply air temperature PDµ for multi-evaporator air-conditioning system

被引:0
|
作者
Wei, Ming-Song [1 ]
Li, Shao-Yong [1 ]
Zhou, Jiao [2 ]
Wang, Cheng-Min [1 ]
Yang, Rui [1 ]
机构
[1] School of Civil Engineering, Lanzhou University of Technology, Gansu, Lanzhou,730050, China
[2] School of Civil Engineering, Tianshui Normal University, Gansu, Tianshui,741000, China
来源
Kongzhi Lilun Yu Yingyong/Control Theory and Applications | 2024年 / 41卷 / 10期
基金
中国国家自然科学基金;
关键词
Adaptive control systems - HVAC - Indoor air pollution - Linear programming - Optimal control systems - Proportional control systems - Relay control systems - Three term control systems - Two term control systems - Window screens;
D O I
10.7641/CTA.2023.20686
中图分类号
学科分类号
摘要
Aiming at regulating performance parameters of the multi evaporator air-conditioning system (MEACS), this project proposes a cascade control mode of indoor temperature PIλDµ and supplys air temperature PDµ and an improved multi-objective artificial fish swarm algorithm (IMOAFSA) is designed to tune parameters of fractional order PID controller for indoor temperature (IT-FOPIDC) and fractional order PD controller for supply air temperature (SAT-FOPDC), so as to stabilize the state point of supply air of MEACS and improve the regulation quality of indoor temperature. Firstly, according to the basic single objective artificial fish swarm algorithm (BSOAFSA), an adaptive factor is constructed to execute the nonlinear decreasing evolution to the visual field and step size in the fish swarm, so an improved single objective artificial fish swarm algorithm (ISOAFSA) is rebuilt. Secondly, on the basis of this ISOAFSA, Gaussian variation is introduced into external files (EF) to design an improved multi-objective artificial fish swarm algorithm (IMOAFSA) in order to continuously tune eight parameters of IT-FOPIDC and SAT-FOPDC. Finally, the control effects hosted by this cascade control system for indoor temperature and supply air temperature are numerically simulated. The results show that the designed IMOAFSA finds out Pareto optimal solutions (POS) of eight parameters of these two controllers and continuously updates them, which can obviously reduce fluctuation of supply air temperature and further improve the control quality of indoor temperature such as minor steady-state error, the smaller overshoot, the appropriate damping ratio and the shorter adjustment time, etc. © 2024 South China University of Technology. All rights reserved.
引用
收藏
页码:1842 / 1852
相关论文
共 50 条
  • [21] Discussion on fresh air volume in Temperature and Humidity Independent Control of Air-conditioning System
    Cheng, Xiaolong
    Liu, Jinxiang
    Wang, Yu
    Yuan, Xiaolei
    Jin, Hui
    2018 2ND INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2018), 2018, 153
  • [22] INDOOR TEMPERATURE CONTROL AND ENERGY SAVING POTENTIAL OF AN AIR CONDITIONING SYSTEM USING PD CONTROLLER
    Nasution, Henry
    Aziz, Azhar Abdul
    Dahlan, Afiq Aiman
    Zulkifli, Amirah Haziqah
    Sumeru
    JURNAL TEKNOLOGI, 2015, 76 (11): : 63 - 67
  • [23] Research of Temperature and Humidity Decoupling Control for Central Air-conditioning System
    Zhao, Xianmei
    Tang, Jie
    Chen, Dongxian
    2009 INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN-MACHINE SYSTEMS AND CYBERNETICS, VOL 2, PROCEEDINGS, 2009, : 404 - 408
  • [24] Space temperature control of a GSHP-integrated air-conditioning system
    Gao, Jiajia
    Huang, Gongsheng
    Xu, Xinhua
    ENERGY AND BUILDINGS, 2015, 108 : 127 - 136
  • [25] Temperature and humidity control with a model predictive control method in the air-conditioning system
    Liu Jingyun
    Li Ping
    2017 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2017, : 408 - 412
  • [26] Air-conditioning system of the future - Thermal storage and low temperature air
    Keeler, Russ
    Construction Specifier, 2002, 55 (01):
  • [27] Research of cascade control with an application to central air-conditioning system
    Wang, Jiang-Jiang
    Zhang, Chun-Fa
    Jing, You-Yin
    PROCEEDINGS OF 2007 INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND CYBERNETICS, VOLS 1-7, 2007, : 498 - 503
  • [28] Simulation of the control effect to the indoor contamination by different air-conditioning mode
    Liu, J
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 404 - 407
  • [29] The applicability of large temperature difference in air-conditioning system
    Sun, W. Z.
    Liu, H. M.
    Zhang, L. H.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 499 - 503
  • [30] Study on Solar Air-Conditioning System of Temperature Difference
    Zhong, Chengyao
    ADVANCED COMPOSITE MATERIALS, PTS 1-3, 2012, 482-484 : 1051 - 1056