Ionization chamber is an important means for on-line measurement of tritium containing gas. Its response is fast but it is affected by many factors. With the development of fusion reactor and other tritium-related systems, on-line tritium activity concentration measurement is more accurate. There are gases with different hydrogen isotope forms (such as H20, НТО and HT) in the helium extracted from the tritium carrier band of the envelope of fusion reactor. In order to study their influence on the tritium measurement in the ionization chamber, a tritium measurement experiment system was established in this study, which mainly included gas allocation unit, gas path circulation unit, ionization chamber unit, chromatographic analysis unit and water vapor drying unit. The system can accurately simulate the cycle state of tritium extraction in the cladding of fusion reactor, and can realize the functions of gas preparation, gas concentration measurement and tritium activity measurement. In this paper, the compound effect theory and He+H2 system theory in ionization chamber tritium measurement, combined with ionization chamber, chromatography, dew point meter and other measuring means, were used to analyze the influence of different hydrogen isotope gas forms containing H20, НТО, H2 in He on tritium measurement. In the experiment, wet high-purity helium, wet tritium-containing helium and dry tritium-containing helium were prepared respectively and slowly filled into the circulation system. In this way, the influence of water vapor on the measurement of ionization chamber and chromatography was studied, and the ion recombination effect during the measurement of ionization chamber under high concentration of tritium was analyzed. The influence of hydrogen on the enhancement effect of tritium measurement in the ionization chamber was verified by measuring the tritium activity concentration in helium carrier gas with different hydrogen concentration. The results show that the detection efficiency of hydrogen isotope gas by ionization chamber and chromatography is lower in water vapor environment than in dry gas environment. In order to ensure the accuracy of measurement, water vapor should be separated or removed during measurement. When the concentration of H20, НТО and HT in the carrier gas increases, the recombination effect in the measurement of the ionization chamber is enhanced, resulting in the measurement results of the ionization chamber being lower than the actual value. The problem can be solved by increasing the working voltage of the ionization chamber or modifying the calibration recombination coefficient. When hydrogen exists in the environment of helium carrier gas, the tritium activity concentration measurement result will increase due to the influence of ionization enhancement effect, but when the hydrogen content exceeds 2 000 ppm, the ionization enhancement effect will approach the saturation state. © 2023 Atomic Energy Press. All rights reserved.
引用
收藏
页码:2428 / 2434
页数:6
相关论文
共 12 条
  • [1] VARNEY R N., Drift velocity of ions in oxygen, nitrogen, and carbon monoxide, Physical Review, 89, pp. 708-711, (1953)
  • [2] JESSE W P, SADAUSKIS J., Alpha-particle ion-ization in mixtures of the noble gases, Physical Review, 88, pp. 417-418, (1952)
  • [3] MENG Dan, CHEN Zhilin, CHANG Ruimin, Et al., Development of online measurement system of tritium in out-of-pile tritium release experiment, Atomic Energy Science and Technology, 48, 3, pp. 528-531, (2014)
  • [4] PLATZMAN R L., Subexcitation electrons, Radiation Research, 2, 1, pp. 1-7, (1955)
  • [5] KIM Y K, RUDD M E., Binary-encounter-dipole model for electron-lmpact-ionization, Physical Review A, 50, 5, pp. 3954-3967, (1994)
  • [6] SATO H, MAEKAWA H, RATO K, Et al., Differential ionization chambers for measuring tritium over a wide range, Radioisotopes, 34, pp. 597-604, (1985)
  • [7] RODRIGO L, MILLER J M, BOKWA S R., Tritium measurement and monitoring in experimental and process system with ionization cham-bers, Fusion Science and Technology, pp. 629-635, (1992)
  • [8] LI Yuqi, ZHAN Qin, CHANG Ming, Et al., Calibration and stability measurement of tritium activity concentration with ionization chamber, Journal of Nuclear and Radiochemistry, 43, 3, pp. 269-273, (2021)
  • [9] MILLER WH., Theory of penning ionization, The Journal of Chemical Physics, 52, pp. 3563-3572, (1970)
  • [10] RODRIGO L., Effect of impurities on the measurement of tritium in inert gases with ionization chambers Jesse effect revisited, Fusion Technology, 28, pp. 1067-1072, (1995)