Joint B0 and Image Reconstruction in Low-Field MRI by Physics-Informed Deep-Learning

被引:3
作者
Schote, David [1 ]
Winter, Lukas [1 ]
Kolbitsch, Christoph [1 ]
Rose, Georg [2 ,3 ]
Speck, Oliver [2 ,3 ]
Kofler, Andreas [1 ]
机构
[1] Phys Tech Bundesanstalt PTB, D-10587 Berlin, Germany
[2] Otto von Guericke Univ, Magdeburg, Germany
[3] Res Campus STIMULATE, Magdeburg, Germany
关键词
Low-field MRI; physics-informed deep learning; image reconstruction; unrolled optimization; field inhomogeneities; MAP ESTIMATION;
D O I
10.1109/TBME.2024.3396223
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: We present a model-based image reconstruction approach based on unrolled neural networks which corrects for image distortion and noise in low-field B-0 similar to 50 mT) MRI. Methods: Utilising knowledge about the underlying physics, a novel network architecture (SH-Net) is introduced which involves the estimation of spherical harmonic coefficients to guarantee a spatially smooth field map estimate. The SH-Net is integrated in an end-to-end trainable model which jointly estimates the B-0-field map as well as the image. Experiments were conducted on retrospectively simulated low-field data of human knees. Results: We compare our model to different model-based approaches at distinct noise levels and various B-0-field distributions. Our results show that our physics-informed neural network approach outperforms the purely model-based methods by improving the PSNR up to 11.7% and the RMSE up to 86.3%. Conclusion: Our end-to-end trained model-based approach outperforms existing methods in reconstructing image and B-0-field maps in the low-field regime. Significance: low-field MRI is becoming increasingly more popular as it enables access to MR in challenging situations such as intensive care units or resource poor areas. Our method allows for fast and accurate image reconstruction in such low-field imaging with B-0-inhomogeneity compensation under a wide range of various environmental conditions.
引用
收藏
页码:2842 / 2853
页数:12
相关论文
共 49 条
  • [41] Sutton BP, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, P489, DOI 10.1109/ISBI.2002.1029301
  • [42] Tamada D, 2020, Arxiv, DOI arXiv:2002.12889
  • [43] Joint B0 and image estimation integrated with model based reconstruction for field map update and distortion correction in prostate diffusion MRI
    Usman, Muhammad
    Kakkar, Lebina
    Matakos, Antonis
    Kirkham, Alex
    Arridge, Simon
    Atkinson, David
    [J]. MAGNETIC RESONANCE IMAGING, 2020, 65 : 90 - 99
  • [44] Image quality assessment: From error visibility to structural similarity
    Wang, Z
    Bovik, AC
    Sheikh, HR
    Simoncelli, EP
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2004, 13 (04) : 600 - 612
  • [45] B0-Shimming Methodology for Affordable and Compact Low-Field Magnetic Resonance Imaging Magnets
    Wenzel, Konstantin
    Alhamwey, Hazem
    O'Reilly, Tom
    Riemann, Layla Tabea
    Silemek, Berk
    Winter, Lukas
    [J]. FRONTIERS IN PHYSICS, 2021, 9
  • [46] Winter L., 2019, Open source medical devices for innovation, education and global health: Case study of open source magnetic resonance imaging, P147
  • [47] Winter L., 2023, First open-source MRI scanner presented: The OSI2 ONE open source imaging
  • [48] Winter L., 2023, Halbach array magnet for in vivo imaging
  • [49] Deep residual network for off-resonance artifact correction with application to pediatric body MRA with 3D cones
    Zeng, David Y.
    Shaikh, Jamil
    Holmes, Signy
    Brunsing, Ryan L.
    Pauly, John M.
    Nishimura, Dwight G.
    Vasanawala, Shreyas S.
    Cheng, Joseph Y.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1398 - 1411