Experimental Analysis On Seismic Behavior Of Prefabricated Reinforced Concrete Column To Steel Beam Exterior Joints With Ribbed Angle Steel

被引:0
作者
Zhang Z.H. [1 ]
Mao G.X. [1 ]
Liu Y. [2 ]
Xiao A.L. [3 ]
Liu Z.L. [4 ]
机构
[1] College of Civil Engineering, Hunan City University, YiYang
[2] Taiyuan University, Taiyuan
[3] Zhongmin Zhuyou Technology Co., Ltd, Changsha
[4] Department of Civil Engineering, University of Auckland, Auckland
来源
Zhang, Z.H. (zaihua_zhang@163.com) | 1600年 / Eastern Macedonia and Thrace Institute of Technology卷 / 14期
关键词
Ductility coefficient; Prefabricated connector with ribbed angle steel; Reinforced concrete-steel beam (RCS) exterior joint; Seismic performance;
D O I
10.25103/jestr.143.11
中图分类号
学科分类号
摘要
Basic structural forms of reinforced concrete column-steel beam composite joints, such as beam-and column-through structures, are difficult to construct due to their complex structure. A joint connection construction method based on the ribbed angle steel was proposed in this study to improve construction performance of such joints, and the industrial assembly construction between reinforced concrete columns and steel beams was realized. By carrying out low cyclic loading test and numerical simulation of three full-scale specimens, the influence of beam–column section,the number of bolts between assembly connectors and steel beams on the performance of joints was examined by carrying out low cyclic loading test and numerical simulation of three full-scale specimens. Moreover, failure mode of joint was analyzed in detail and seismic performance indexes, such as bearing capacity, hysteretic performance, ductility, and energy dissipation capacity of joints, were compared. The results reveal that for different resistance matching among columns, beams, and connectors with ribbed angle steel, there are three failure modes of the joints, namely, shear failure in core area, slip at beam end, and slip at beam end with shear failure in core area. Seismic performance of joints varies with their failure modes. Hysteretic curve of shear failure joint in the core area shows evident pinch phenomenon. Ductility and equivalent viscous damping coefficients are 2.026 and 0.11, respectively. The seismic performance of the joint is consistent with that of the cast-in-place reinforced concrete beam–column joint. The hysteretic curve of the joint is full, ductility, and equivalent viscous damping coefficients reach 3.89 and 0.23, respectively, when slip exists between the connector and the steel beam. The joint demonstrates satisfactory seismic performance. This study provides an experimental basis for the engineering application of the novel prefabricated connection joint. © 2021 School of Science, IHU. All rights reserved.
引用
收藏
页码:91 / 102
页数:11
相关论文
共 50 条
  • [41] Experimental study on seismic behavior of irregular H-shaped steel beam-to-column joints filled with concrete made of DCLs
    Sun Y.
    Liu Q.
    Liu W.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (12): : 85 - 92
  • [42] Experimental investigation on the seismic performance of prefabricated fiber-reinforced concrete beam-column joints using grouted sleeve connections
    Sun, Chuanzhi
    Zhuang, Mei-Ling
    Wang, Zhenbo
    Chen, Baodong
    Gao, Li
    Qiao, Yan
    Zhu, Hanbo
    Zhang, Weihua
    Yang, Jun
    Yu, Changrong
    STRUCTURAL CONCRETE, 2023, 24 (04) : 4702 - 4718
  • [43] Experimental study on seismic performance of prefabricated replaceable beam-column connectors using double-sided angle steel
    Sun, Dongde
    Yang, Yong
    Ma, Yinke
    Xue, Yicong
    Yu, Yunlong
    Feng, Shiqiang
    JOURNAL OF BUILDING ENGINEERING, 2022, 51
  • [44] Study on seismic performance of beam-end flange reinforced joints of concrete-filled centrifugal precast concrete column-steel beam
    Zhang, Xizhi
    Di, Yao
    Guo, Guanghai
    Zhang, Shaohua
    Li, Xingqian
    Pu, Yuta
    Liang, Jian
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (12): : 72 - 83
  • [45] Behavior of exterior concrete beam-column joints reinforced with Shape Memory Alloy (SMA) bars
    Azariani, Hossein Rezaee
    Esfahani, M. Reza
    Shariatmadar, Hashem
    STEEL AND COMPOSITE STRUCTURES, 2018, 28 (01) : 83 - 98
  • [46] Research on Seismic Performance of Prefabricated Steel Reinforced Concrete Composite Walls
    Huang, Wei
    Liu, Gang
    Miao, Xinwei
    Wang, Wei
    Zhang, Chenlong
    Zhang, Hao
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (11): : 115 - 125
  • [47] Experimental study on the seismic performance of a prefabricated steel column-column connection
    Yang, Yong
    Xu, Longkang
    Feng, Shiqiang
    Sun, Dongde
    Xue, Yicong
    Yu, Yunlong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 194
  • [48] Experimental and numerical studies on seismic behavior of bonded and unbonded prestressed steel reinforced concrete frame beam
    Xiong, Xueyu
    Yao, Gangfeng
    Su, Xiaozu
    ENGINEERING STRUCTURES, 2018, 167 : 567 - 581
  • [49] Experimental and numerical evaluation of steel fibres RC patterns influence on the seismic behaviour of the exterior concrete beam-column connections
    Pour, Arash Karimi
    ENGINEERING STRUCTURES, 2022, 263
  • [50] Slab Reinforcement Contributions to Negative Moment Strength of Reinforced Concrete T-Beam with High Strength Steel at Exterior Beam-Column Joints
    Mamesh, Zhamilya
    Sailauova, Dilnura
    Zhang, Dichuan
    Ju, Hyunjin
    Lee, Deuckhang
    Kim, Jong
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2023, 17 (01)