Performance of thermally enhanced backfill material in vertical ground heat exchangers under continuous operation in a cooling season

被引:2
|
作者
Liu, Xinye [1 ]
Zhang, Guozhu [1 ]
Wu, Ruichun [2 ]
Chen, Panpan [2 ]
Guo, Junhui [2 ]
Wan, Jun [2 ]
机构
[1] Southeast Univ, Jiangsu Key Lab Low Carbon & Sustainable Geotech E, Nanjing 211189, Peoples R China
[2] Hongyuan Elect Power Design Inst Co Ltd, Taizhou 318000, Peoples R China
关键词
Vertical ground heat exchangers; Backfill materials of high thermal conductivity; Heat transfer efficiency; Performance evaluation in a cooling season; PHC ENERGY PILE; GROUTING MATERIALS; FLOW; MODEL; TEMPERATURE; EFFICIENCY; ADVECTION; SURFACE; DESIGN; IMPACT;
D O I
10.1016/j.applthermaleng.2024.124442
中图分类号
O414.1 [热力学];
学科分类号
摘要
Backfill materials in vertical ground heat exchangers significantly affect the heat-transfer efficiency of groundsource heat pump systems. In this study, the use of graphite improving the thermal conductivity of backfill materials is investigated via laboratory tests, and its feasibility is verified via in-situ thermal response testing. Based on the results, the relationship between the coefficient of performance (COP) and thermally enhanced backfill materials is built through a numerical model. The variation of COP under different thermal-physical soil conditions and backfill materials with enhanced thermal conductivities is investigated; then a method for selecting backfill materials is proposed by matching thermal properties of backfill material and surrounding soil. The results indicate that when the soil thermal conductivity is at a relatively low level of 1.0 W/(m center dot K), the highest COP improvement ratios range between 7.99 % and 16.13 % during the 90 days operation However, the COP improvement ratio decreases gradually as the soil thermal conductivity increases, and the COP improvement ratios decrease to less than 1.0 % as the soil thermal conductivity increases to 5.0 W/(m center dot K). Parameterdesign charts are made to intuitively illustrate the COP variation. The result of contributions of influencing parameters shows that high-velocity groundwater seepage contributes positively to COP improvement, followed by thermal conductivity of soil, and then that of backfill material during a cooling season.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] The Effect of Shank-Space on the Thermal Performance of Shallow Vertical U-Tube Ground Heat Exchangers
    Vella, Christopher
    Borg, Simon Paul
    Micallef, Daniel
    ENERGIES, 2020, 13 (03)
  • [32] Simulation of heat transfer and effectiveness in a helical heat exchanger made from thermally enhanced polymer material for use in absorption cooling
    Ahmadu, Talib
    Dandajeh, Hamisu Adamu
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (03): : 602 - 613
  • [33] STEADY-STATE FREE-CONVECTIVE COOLING OF HEAT-EXCHANGERS WITH VERTICAL RECTANGULAR FINS - EFFECT OF FIN MATERIAL
    KO, YM
    LEUNG, CW
    PROBERT, SD
    APPLIED ENERGY, 1989, 34 (03) : 181 - 191
  • [34] Numerical performance analysis of modified vertical U-tube ground heat exchangers by adjusting the impact of leg spacing
    Chowdhury, Nafisa Riza
    Toslim, Abu Hena
    Ali, Md. Hasan
    Miyara, Akio
    International Journal of Thermofluids, 2024, 24
  • [35] Performance evaluation of closed-loop vertical ground heat exchangers by conducting in-situ thermal response tests
    Lee, Chulho
    Park, Moonseo
    The-Bao Nguyen
    Sohn, Byonghu
    Choi, Jong Min
    Choi, Hangseok
    RENEWABLE ENERGY, 2012, 42 : 77 - 83
  • [36] Performance study of a heat pump fresh air unit based on desiccant coated heat exchangers under different operation strategies
    Yang, Tianyu
    Ge, Tianshu
    ENERGY, 2024, 296
  • [37] Field study on cooling performance of a heat recovery ground source heat pump system coupled with thermally activated building systems (TABSs)
    Hu, Rong
    Li, Xiaoping
    Liang, Jincan
    Wang, Haolin
    Liu, Gang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 262
  • [38] Field study on cooling performance of a heat recovery ground source heat pump system coupled with thermally activated building systems (TABSs)
    Hu, Rong
    Li, Xiaoping
    Liang, Jincan
    Wang, Haolin
    Liu, Gang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 262
  • [39] Enhanced cooling performance of magnetic nanofluids in tri-coaxial tube heat exchangers with magnetically induced swirling flow
    Gaur, Sunil Kumar
    Sahoo, Rashmi Rekha
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 61
  • [40] In situ operation performance test of ground coupled heat pump system for cooling and heating provision in temperate zone
    Man, Yi
    Yang, Hongxing
    Wang, Jinggang
    Fang, Zhaohong
    APPLIED ENERGY, 2012, 97 : 913 - 920