Experimental study of two-phase pressure-drop in horizontal return bends with ammonia

被引:1
作者
Muzaffar, Atif [1 ]
Abbas, Ahmad [1 ,2 ]
Cremaschi, Lorenzo [2 ]
Ayub, Zahid [3 ]
机构
[1] Ghulam Ishaq Khan Inst Engn Sci & Technol, Fac Mech Engn, Topi 23460, Pakistan
[2] Auburn Univ, Dept Mech Engn, Auburn, AL USA
[3] Isotherm Inc, Arlington, TX USA
关键词
Ammonia; Pressure-drop; Return bends; Two-phase; Ammoniac; chute de pression; virages de retour; deux phases; CONTIGUOUS STRAIGHT TUBES; FLOW PATTERN; U-BENDS; DIFFERENT REFRIGERANTS; MICROFIN TUBE; HEAT-TRANSFER; R-22; ORIENTATIONS; EVAPORATION; BEHAVIOR;
D O I
10.1016/j.ijrefrig.2024.09.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
In evaporators and condensers of refrigeration and air conditioning systems, various straight tubes are joined via U-bends. These U-bends result in higher pressure drops due to flow disturbances and centrifugal effects. Accurate prediction of pressure drops in these bends is essential for reliable design and operation. This study investigates the two-phase flow pressure-drop in horizontal U-bends with ammonia under wide range of experimental conditions. Three pipes with nominal outer diameter between 22.2, 15.9, and 9.5 mm were used, each with three bend radii (R/do ratio) between 1.2 and 2.5 in horizontal configuration. Tests were conducted at saturation temperature of +10 and -15 degrees C, with mass flux varying between 10 and 50 kg m- 2 s- 1, and vapor quality between 0.1 and 0.9. The pressure-drop increased with mass flux and vapor quality while decreased with saturation temperature, pipe diameter and R/do ratio of the bend. Large tubes exhibited a greater increase in pressure drop with rising mass flux and decreasing bend ratio compared to small tubes, which showed higher absolute values and more consistent performance across the vapor quality range at both saturation temperatures. The tube diameter had a less significant effect at high saturation temperature and high mass flux, while the bend curvature ratio predominantly influenced the pressure drop performance for large diameter tubes. One correlation from the literature predicted the data well only if the vapor quality was below 0.5. For wider range of quality, the existing models in the literature were not well-suited for predicting pressure drops in ammonia U-bends.
引用
收藏
页码:593 / 606
页数:14
相关论文
共 36 条
  • [1] Experimental study of ammonia flow boiling in a vertical tube bundle: Part 1-Enhanced dimple tube
    Abbas, Ahmad
    Ayub, Zahid H.
    Ismail, Tauseef
    Ayub, Adnan H.
    Li, Wei
    Khan, Tariq S.
    Ribatski, Gherhardt
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 286 - 299
  • [2] Shell side direct expansion evaporation of ammonia on a plain tube bundle with inlet quality effect in the presence of exit superheat
    Abbas, Ahmad
    Ayub, Zahid H.
    Ayub, Adnan H.
    Chattha, Javed A.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 82 : 11 - 21
  • [3] Flow pattern and pressure drop for oil-water flows in and around 180° bends
    Ayegba, Paul Onubi
    Edomwonyi-Otu, Lawrence C.
    Abubakar, Abdulkareem
    Yusuf, Nurudeen
    [J]. SN APPLIED SCIENCES, 2021, 3 (01):
  • [4] Two-phase frictional pressure drop measurements in U-type wavy tubes subject to horizontal and vertical arrangements
    Chen, Ing Youn
    Wu, Yu-Shi
    Liaw, Jane-Sunn
    Wang, Chi-Chuan
    [J]. APPLIED THERMAL ENGINEERING, 2008, 28 (8-9) : 847 - 855
  • [5] Measurements and correlations of frictional single-phase and two-phase pressure drops of R-410A flow in small U-type return bends
    Chen, IY
    Wang, CC
    Lin, SY
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (10-11) : 2241 - 2249
  • [6] Chisholm D., 1983, Two-phase flow in pipelines and heat exchangers
  • [7] Condensation heat transfer for R-22 and R-407C refrigerant-oil mixtures in a microfin tube with a U-bend
    Cho, K
    Tae, SJ
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (11) : 2043 - 2051
  • [8] Evaporation heat transfer for R-22 and R-407C refrigerant-oil mixture in a microfin tube with a U-bend
    Cho, K
    Tae, SJ
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (03): : 219 - 231
  • [9] Christoffersen B.R., 1993, Air Conditioning and Refrigeration Center TR-47
  • [10] Cotter D., 2009, PhD Thesis