High-sensitive double incidence multi-pass cell for trace gas detection based on TDLAS

被引:5
|
作者
Shi, Yongpeng [1 ,2 ]
Hu, Zhen [1 ,2 ]
Niu, Mingsheng [1 ,2 ]
Li, Taohua [1 ,2 ]
Li, Hui [1 ,2 ]
Liu, Huiyuan [1 ,2 ]
Li, Xiangxian [3 ]
机构
[1] Qufu Normal Univ, Sch Phys & Phys Engn, Qufu 273165, Peoples R China
[2] Qufu Normal Univ, Laser Res Inst, Qufu 273165, Peoples R China
[3] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Gas detection system; TDLAS; Dual-incidence multi-pass cell; Laser frequency correction; Wavelength modulation spectroscopy; Atmospheric monitoring; EMISSIONS; METHANE; SENSOR; H2O; N2O;
D O I
10.1016/j.snb.2024.135829
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high-precision gas detection system with a dual-incidence multi-pass cell (D-MPC) based on TDLAS was developed, which can simultaneously measure quadruple component gases. Two Distributed Feedback (DBF) Laser Diodes with central wavelength of 1654 nm and 2004 nm were utilized to measure methane (CH4) and carbon dioxide (CO2) for evaluating the performance of the system. High sensitivity and low frequency drift were accomplished by utilizing the second harmonic signals (WMS-2f) detection and peak-locking technology. A LabVIEW-based control and acquisition program, which could be used for direct absorption and wavelength modulation, was developed. Kalman adaptive filtering, Least Mean Squares (LMS) adaptive filtering and S-G filtering were employed for denoising in direct absorption spectroscopy (DAS), respectively, and optimal denoising technology of S-G filtering was selected. According to Allan deviation analysis, the optimal detection precision for CH4 and CO2 was 12 ppb at an integration time of 36 s and 270 ppb at an integration time of 43 s, respectively. A two-day continuous monitoring of atmospheric CO2 and CH4 was implemented to verify the system stability and can be applied to other trace gases monitoring.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Methane detection system based on a new type of dense optical multi-pass cell
    Yang, Hongtao
    Peng, Jingjing
    OPTIK, 2022, 268
  • [22] Compact Multi-pass Cell based Faraday Rotation Spectrometer for Nitric Oxide detection
    Wang, Yin
    Nikodem, Michal
    Brumfield, Brian
    Wysocki, Gerard
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [23] Multi-pass cell spectral broadening at high pulse energies
    Tavella, F.
    Mecseki, K.
    PHYSICS OF PLASMAS, 2022, 29 (08)
  • [24] ROLLER TRACE DESIGN IN MULTI-PASS CONVENTIONAL SPINNING BASED ON CYLINDRICAL PART
    Li Zixuan
    Shu Xuedao
    Ye Bohai
    Wang Jitai
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 2A, 2020,
  • [25] Measurement of Ammonia by a Portable UV-DOAS Gas Sensor Based on Multi-Pass Cell
    Wang, Jie
    Xie, Pinhua
    Li, Ang
    Si, Fuqi
    Dou, Ke
    Fang, Wu
    Wu, Fengcheng
    Jiang, Yu
    Qin, Min
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS IV, 2010, 7853
  • [26] Triple-range adjustable plane-concave multipass gas cell for high-precision trace gas detection based on TDLAS
    Hu, Zhen
    Shi, Yongpeng
    Niu, Mingsheng
    Li, Taohua
    Li, Hui
    Liu, Huiyuan
    OPTICS AND LASERS IN ENGINEERING, 2024, 175
  • [27] Highly Sensitive Carbon Dioxide Gas Sensor Based on 2 μm Laser Diode and Herriott Multi-pass Absorption Cell (Invited)
    Wang Chenglong
    Xie Jiabao
    Zhuang Ruobin
    Lin Haoyang
    Lin Leqing
    Cui Ruyue
    Wu Hongpeng
    Zheng Huadan
    Dong Lei
    ACTA PHOTONICA SINICA, 2023, 52 (10)
  • [28] Generalized Optical Design of the Double-Row Circular Multi-Pass Cell
    Yang, Zheng
    Guo, Yin
    Ming, Xianshun
    Sun, Liqun
    SENSORS, 2018, 18 (08)
  • [29] Study on High Sensitive Detection of Acetylene Trace Gas Based on QEPAS
    Ma Yu-fei
    Tong Yao
    Zhang Li-gong
    He Ying
    Zhang Jing-bo
    Wang Long
    Long Jin-hu
    Yu Xin
    Sun Rui
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (09) : 2869 - 2872
  • [30] Compact optical fiber photoacoustic gas sensor with integrated multi-pass cell
    Fan, Enbo
    Liu, Haojie
    Wang, Chao
    Ma, Jun
    Guan, Bai-Ou
    PHOTOACOUSTICS, 2023, 32