In silico analysis on sacroiliac joint fixation during normal walking

被引:0
|
作者
Toyohara, Ryota [1 ,2 ]
Kurosawa, Daisuke [3 ]
Hammer, Niels [4 ,5 ,6 ]
Ohashi, Toshiro [1 ]
机构
[1] Faculty of Engineering, Hokkaido University, N13W8, Kita-ku, Hokkaido, Sapporo
[2] Creative Research Institution, Hokkaido University, N12W7, Kita-ku, Hokkaido, Sapporo
[3] Japan Sacroiliac Joint and Low Back Pain Center, Department of Orthopedic Surgery, JCHO Sendai Hospital, 2-1-1 Murasakiyama, Izumi-ku, Miyagi, Sendai
[4] Division of Clinical and Macroscopic Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Auenbruggerplatz 25, Graz
[5] Department of Orthopedic and Trauma Surgery, University of Leipzig, Liebigstraße 20, Leipzig
[6] Division of Biomechatronics, Fraunhofer Institute for Machine Tools and Forming Technology (IWU), Nöthnitzer Str. 44, Dresden
来源
Journal of Biomechanical Science and Engineering | 2024年 / 19卷 / 04期
基金
日本学术振兴会;
关键词
Arthrodesis; Finite element analysis; Implant; Pelvic kinematics; Sacroiliac joint; Walking analysis;
D O I
10.1299/jbse.24-00036
中图分类号
学科分类号
摘要
According to medical statistics, sacroiliac joints (SIJs) appear to be the source of low back pain in 15–30% of cases. The SIJs are located at the junction between the sacrum and the ilium, supported by strong ligaments and with low mobility. Due to unexpected external force or repeated impact, pain may arise from the SIJ region (SIJ dysfunction). The treatment to cure SIJ dysfunction includes nonsurgical approaches as well as surgery with implants (SIJ fixation). Previous studies have assessed the consequences of SIJ fixation, but no simulation study so far has been performed during walking. The SIJ is burdened with variant loads during walking. In this given study, walking conditions were replicated in a finite element model of the pelvis combined with 3D walking analysis data. The simulation mimicked two types of unilateral SIJ fixation: anterior fixation with a plate implant and screws (model A) and posterior fixation with a rod, a cage and screws (model P). Equivalent stress of the SIJ and the loading of the SIJ ligaments decreased in the fixed models. In these fixed pelves, the slight motion on the SIJ decreased. The reduction rates on equivalent stress, ligament loads and equivalent stress were low during the swing phase. In addition, the efficiency of fixations was mostly same on anterior and posterior fixations. It can be concluded that the stronger fixation reduces the loading but also may have a greater impairment effects on walking. © 2024 The Japan Society of Mechanical Engineers. This is an open access article under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/).
引用
收藏
相关论文
共 50 条
  • [31] Effects on hip stress following sacroiliac joint fixation: A finite element study
    Joukar, Amin
    Chande, Ruchi D.
    Carpenter, R. Dana
    Lindsey, Derek P.
    Erbulut, Deniz U.
    Yerby, Scott A.
    Duhon, Bradley
    Goel, Vijay K.
    JOR SPINE, 2019, 2 (04):
  • [32] Percutaneous Sacroiliac Joint Fixation in Sacroiliac Instability The First Case Report Using a Fully CT-Guided Technique
    Manfre, Luigi
    INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (05) : 621 - 625
  • [33] Phase-specific changes in hip joint loading during gait following sacroiliac joint fusion: Findings from a finite element analysis
    Kumaran, Yogesh
    Bonsu, Janice M.
    Tripathi, Sudharshan
    Soehnlen, Sophia M.
    Quatman, Carmen E.
    CLINICAL BIOMECHANICS, 2025, 122
  • [34] Biomechanical analysis of motion following sacroiliac joint fusion using lateral sacroiliac screws with or without lumbosacral instrumented fusion
    Dall, Bruce E.
    Eden, Sonia, V
    Cho, Woojin
    Karkenny, Alexa
    Brooks, Daina M.
    Hayward, Gerald M., II
    Moldavsky, Mark
    Yandamuri, Soumya
    Bucklen, Brandon S.
    CLINICAL BIOMECHANICS, 2019, 68 : 182 - 189
  • [35] Implantation of S1AIS has priority as a sacroiliac joint fixation technique
    Zhao, Kai
    Wang, Yapeng
    Li, Dong
    Ding, Yanping
    Yang, Ying
    Yin, Qudong
    Ma, Yunhong
    EUROPEAN SPINE JOURNAL, 2024, 33 (09) : 3567 - 3575
  • [36] Ilio-Sacral (IS) Screw Fixation for Sacral and Sacroiliac Joint (SIJ) Injuries in Children
    Abdelgawad, Amr A.
    Davey, Shaunette
    Salmon, Jordan
    Gurusamy, Preet
    Kanlic, Enes
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (02) : 117 - 121
  • [37] Sex Specific Sacroiliac Joint Biomechanics During Standing Upright A Finite Element Study
    Joukar, Amin
    Shah, Anoli
    Kiapour, Ali
    Vosoughi, Ardalan Seyed
    Duhon, Bradley
    Agarwal, Anand K.
    Elgafy, Hossein
    Ebraheim, Nabil
    Goel, Vijay K.
    SPINE, 2018, 43 (18) : E1053 - E1060
  • [38] A Systematic Review of the Normal Sacroiliac Joint Anatomy and Adjacent Tissues for Pain Physicians
    Poilliot, Amelie J.
    Zwirner, Johann
    Doyle, Terence
    Hammer, Niels
    PAIN PHYSICIAN, 2019, 22 (04) : E247 - E274
  • [39] Movement of the sacroiliac joint during the Active Straight Leg Raise test in patients with long-lasting severe sacroiliac joint pain
    Kibsgard, Thomas J.
    Rohrl, Stephan M.
    Roise, Olav
    Sturesson, Bengt
    Stuge, Britt
    CLINICAL BIOMECHANICS, 2017, 47 : 40 - 45
  • [40] Lumbar Fusion including Sacroiliac Joint Fixation Increases the Stress and Angular Motion at the Hip Joint: A Finite Element Study
    Kozaki, Takuhei
    Hashizume, Hiroshi
    Oka, Hiroyuki
    Ohashi, Satoru
    Kumano, Yoh
    Yamamoto, Ei
    Minamide, Akihito
    Yukawa, Yasutsugu
    Iwasaki, Hiroshi
    Tsutsui, Shunji
    Takami, Masanari
    Nakata, Keiji
    Taniguchi, Takaya
    Fukui, Daisuke
    Nishiyama, Daisuke
    Yamanaka, Manabu
    Tamai, Hidenobu
    Taiji, Ryo
    Murata, Shizumasa
    Murata, Akimasa
    Yamada, Hiroshi
    SPINE SURGERY AND RELATED RESEARCH, 2022, 6 (06): : 681 - 688