In silico analysis on sacroiliac joint fixation during normal walking

被引:0
|
作者
Toyohara, Ryota [1 ,2 ]
Kurosawa, Daisuke [3 ]
Hammer, Niels [4 ,5 ,6 ]
Ohashi, Toshiro [1 ]
机构
[1] Faculty of Engineering, Hokkaido University, N13W8, Kita-ku, Hokkaido, Sapporo
[2] Creative Research Institution, Hokkaido University, N12W7, Kita-ku, Hokkaido, Sapporo
[3] Japan Sacroiliac Joint and Low Back Pain Center, Department of Orthopedic Surgery, JCHO Sendai Hospital, 2-1-1 Murasakiyama, Izumi-ku, Miyagi, Sendai
[4] Division of Clinical and Macroscopic Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Auenbruggerplatz 25, Graz
[5] Department of Orthopedic and Trauma Surgery, University of Leipzig, Liebigstraße 20, Leipzig
[6] Division of Biomechatronics, Fraunhofer Institute for Machine Tools and Forming Technology (IWU), Nöthnitzer Str. 44, Dresden
来源
Journal of Biomechanical Science and Engineering | 2024年 / 19卷 / 04期
基金
日本学术振兴会;
关键词
Arthrodesis; Finite element analysis; Implant; Pelvic kinematics; Sacroiliac joint; Walking analysis;
D O I
10.1299/jbse.24-00036
中图分类号
学科分类号
摘要
According to medical statistics, sacroiliac joints (SIJs) appear to be the source of low back pain in 15–30% of cases. The SIJs are located at the junction between the sacrum and the ilium, supported by strong ligaments and with low mobility. Due to unexpected external force or repeated impact, pain may arise from the SIJ region (SIJ dysfunction). The treatment to cure SIJ dysfunction includes nonsurgical approaches as well as surgery with implants (SIJ fixation). Previous studies have assessed the consequences of SIJ fixation, but no simulation study so far has been performed during walking. The SIJ is burdened with variant loads during walking. In this given study, walking conditions were replicated in a finite element model of the pelvis combined with 3D walking analysis data. The simulation mimicked two types of unilateral SIJ fixation: anterior fixation with a plate implant and screws (model A) and posterior fixation with a rod, a cage and screws (model P). Equivalent stress of the SIJ and the loading of the SIJ ligaments decreased in the fixed models. In these fixed pelves, the slight motion on the SIJ decreased. The reduction rates on equivalent stress, ligament loads and equivalent stress were low during the swing phase. In addition, the efficiency of fixations was mostly same on anterior and posterior fixations. It can be concluded that the stronger fixation reduces the loading but also may have a greater impairment effects on walking. © 2024 The Japan Society of Mechanical Engineers. This is an open access article under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/).
引用
收藏
相关论文
共 50 条
  • [21] Joint coordinate system for biomechanical analysis of the sacroiliac joint
    Van Hauwermeiren, Liesbeth
    Verstraete, Matthias
    Stouthandel, Michael E. J.
    Van Oevelen, Aline
    De Gersem, Werner
    Delrue, Louke
    Achten, Eric
    Adriaens, Dominique
    Van Hoof, Tom
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2019, 37 (05) : 1101 - 1109
  • [22] Biomechanics of sacroiliac joint fixation using lag screws: a cadaveric study
    Chatain, Gregoire P.
    Oldham, Alton
    Uribe, Juan
    Duhon, Bradley
    Gardner, Michael J.
    Witt, Jens-Peter
    Yerby, Scott
    Kelly, Brian P.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [23] Posterior hinge fixation for the treatment of unstable traumatic sacroiliac joint injuries
    Gauthe, Remi
    Lefevre, Emeric
    Dujardin, Franck
    Foulongne, Emmanuel
    Hoffmann, Etienne
    Lalevee, Matthieu
    Ould-Slimane, Mourad
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (02)
  • [24] Biomechanics of sacroiliac joint fixation using lag screws: a cadaveric study
    Grégoire P. Chatain
    Alton Oldham
    Juan Uribe
    Bradley Duhon
    Michael J. Gardner
    Jens-Peter Witt
    Scott Yerby
    Brian P. Kelly
    Journal of Orthopaedic Surgery and Research, 18
  • [25] Minimally Invasive Sacroiliac Joint Fusion vs Conservative Management in Patients With Sacroiliac Joint Dysfunction: A Systematic Review and Meta-Analysis
    Hermans, Sem M. M.
    Droeghaag, Ruud
    Schotanus, Martijn G. M.
    van Santbrink, Henk
    van Hemert, Wouter L. W.
    Curfs, Inez
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2022, 16 (03) : 472 - 480
  • [26] Individuals with sacroiliac joint dysfunction display asymmetrical gait and a depressed synergy between muscles providing sacroiliac joint force closure when walking
    Feeney, Daniel F.
    Capobianco, Robyn A.
    Montgomery, Jana R.
    Morreale, Joseph
    Grabowski, Alena M.
    Enoka, Roger M.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 43 : 95 - 103
  • [27] Appearance of the sacroiliac joint in ventrodorsal radiographs of the normal canine pelvis
    Knaus, I
    Breit, S
    Kunzel, W
    VETERINARY RADIOLOGY & ULTRASOUND, 2003, 44 (02) : 148 - 154
  • [28] Quantitative sacroiliac joint scintigraphy in normal subjects and patients with sacroiliitis
    Kaçar G.
    Kaçar C.
    Karayalçin B.
    Güngör F.
    Tuncer T.
    Erkiliç M.
    Annals of Nuclear Medicine, 1998, 12 (3) : 169 - 173
  • [29] Biomechanical comparison of three kinds of fixation in fracture-dislocation of the sacroiliac joint
    Wu, Tao
    Su, Ke
    Zhang, Ying-Ze
    Yang, Zong-You
    Li, Hui-Jie
    Han, Yong-Tai
    TECHNOLOGY AND HEALTH CARE, 2019, 27 (01) : 89 - 99
  • [30] In Vitro Biomechanical Evaluation of a Novel, Minimally Invasive, Sacroiliac Joint Fixation Device
    Cross, William W., III
    Berven, Sigurd H.
    Slater, Nick
    Lehrman, Jennifer N.
    Newcomb, Anna G. U. S.
    Kelly, Brian P.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2018, 12 (05): : 587 - 594