Characterization of monoclonal antibody charge variants under near-native separation conditions using nanoflow sheath liquid capillary electrophoresis-mass spectrometry

被引:0
作者
Zon, Annika A. M. van der [1 ,2 ]
Hoechsmann, Alisa [3 ,4 ]
Bos, Tijmen S. [1 ,2 ]
Neusuess, Christian [3 ]
Somsen, Govert W. [2 ,5 ]
Jooss, Kevin [2 ,5 ]
Haselberg, Rob [2 ,5 ]
Gargano, Andrea F. G. [1 ,2 ]
机构
[1] Univ Amsterdam, Van Hoff Inst Mol Sci, Analyt Chem Grp, Sci Pk 904, NL-1098 XH Amsterdam, Netherlands
[2] Ctr Analyt Sci Amsterdam, Sci Pk 904, NL-1098 XH Amsterdam, Netherlands
[3] Aalen Univ, Dept Chem, Beethovenstr 1, D-73430 Aalen, Germany
[4] Eberhard Karls Univ Tubingen, Fac Sci, D-72074 Tubingen, Germany
[5] Vrije Univ Amsterdam, Amsterdam Inst Mol & Life Sci, Dept Chem & Pharmaceut Sci, Div BioAnalyt Chem, De Boelelaan 1085, NL-1081 HV Amsterdam, Netherlands
关键词
Monoclonal antibodies; Charge heterogeneity; Capillary zone electrophoresis; Mass spectrometry; ZONE-ELECTROPHORESIS; HETEROGENEITY; PROTEINS; INTACT;
D O I
10.1016/j.aca.2024.343287
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Monoclonal antibodies (mAbs) undergo multiple post-translational modifications (PTMs) during production and storage, resulting for instance in charge and oxidized variants. PTMs need to be assessed as critical quality attributes to assure protein quality and safety. Capillary zone electrophoresis (CZE) enables efficient charge-based separation. The CZE method developed by He et al. (2011) is currently applied routinely in the pharmaceutical industry for profiling charge heterogeneity of mAbs. However, as the method relies on a non volatile background electrolyte (BGE), it cannot be directly hyphenated with mass spectrometry (MS), hampering the identification of separated charge variants. Results: This study presents a CZE-UV/MS method using a neutral static capillary coating of hydroxypropyl methylcellulose combined with a volatile BGE at pH 5.0 to allow for MS-compatible mAb charge variant separations. The effect of several parameters, including pH and concentration of the BGE, applied voltage, and injected mAb concentrations on separation performance was investigated using a panel of commercially available mAbs. The optimized method was evaluated with IgG1 and IgG4 mAbs of varying pI(7.4-9.2) and degrees of heterogeneity. Basic and acidic variants were separated from the parent mAb using a BGE of 50 mM acetic acid adjusted to pH 5.0 with ammonium hydroxide. The relative abundances of charge variants determined with the new method showed a good correlation with the corresponding relative levels obtained with the method of He et al. CZE-MS coupling was accomplished using the nanoCEasy, a low-flow sheath liquid interface, which enabled the identification and quantitation of basic, acidic, and incomplete pyroglutamate variants, and glycoforms of the tested mAbs. Significance: This manuscript describes a new CZE-MS method that permits heterogeneity assessment of mAbs under MS-compatible conditions, providing charge variant separation.
引用
收藏
页数:9
相关论文
共 53 条
[11]   Chromatographic analysis of the acidic and basic species of recombinant monoclonal antibodies [J].
Du, Yi ;
Walsh, Alison ;
Ehrick, Robin ;
Xu, Wei ;
May, Kimberly ;
Liu, Hongcheng .
MABS, 2012, 4 (05) :578-585
[12]   Ion-exchange chromatography for the characterization of biopharmaceuticals [J].
Fekete, Szabolcs ;
Beck, Alain ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 113 :43-55
[13]   LIQUID SHEATH EFFECTS ON THE SEPARATION OF PROTEINS IN CAPILLARY ELECTROPHORESIS ELECTROSPRAY MASS-SPECTROMETRY [J].
FORET, F ;
THOMPSON, TJ ;
VOUROS, P ;
KARGER, BL ;
GEBAUER, P ;
BOCEK, P .
ANALYTICAL CHEMISTRY, 1994, 66 (24) :4450-4458
[14]   Comparative Elucidation of Cetuximab Heterogeneity on the Intact Protein Level by Cation Exchange Chromatography and Capillary Electrophoresis Coupled to Mass Spectrometry [J].
Fussl, Florian ;
Trappe, Anne ;
Carillo, Sara ;
Jakes, Craig ;
Bones, Jonathan .
ANALYTICAL CHEMISTRY, 2020, 92 (07) :5431-5438
[15]   Determination of isoelectric points and relative charge variants of 23 therapeutic monoclonal antibodies [J].
Goyon, Alexandre ;
Excoffier, Melissa ;
Janin-Bussat, Marie-Claire ;
Bobaly, Balazs ;
Fekete, Szabolcs ;
Guillarme, Davy ;
Beck, Alain .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1065 :119-128
[16]   Affinity capillary electrophoresis - mass spectrometry permits direct binding assessment of IgG and FcγRIIa in a glycoform-resolved manner [J].
Gstottner, Christoph ;
Knaupp, Alexander ;
Vidarsson, Gestur ;
Reusch, Dietmar ;
Schlothauer, Tilman ;
Wuhrer, Manfred ;
Dominguez-Vega, Elena .
FRONTIERS IN IMMUNOLOGY, 2022, 13
[17]   Bioprocess Challenges in Purification of Therapeutic Protein Charge Variants [J].
Gupta, Tarun ;
Kumar, Anuj ;
Seshadri, Sriram .
BIOTECHNOLOGY AND BIOPROCESS ENGINEERING, 2023, 28 (04) :493-506
[18]   Electromigration peak dispersion of isotachophoretic protein zones during capillary zone electrophoresis [J].
Gysler, J ;
Jaehde, U ;
Schunack, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05) :398-403
[19]   Recent advances in column coatings for capillary electrophoresis of proteins [J].
Hajba, Laszlo ;
Guttman, Andras .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 90 :38-44
[20]   Heterogeneity assessment of antibody-derived therapeutics at the intact and middle-up level by low-flow sheathless capillary electrophoresis-mass spectrometry [J].
Haselberg, Rob ;
De Vijlder, Thomas ;
Heukers, Raimond ;
Smit, Martine J. ;
Romijn, Edwin P. ;
Somsen, Govert W. ;
Dominguez-Vega, Elena .
ANALYTICA CHIMICA ACTA, 2018, 1044 :181-190